Preliminary results on the various U.V. straylight sources for the VWFC onboard SL 1

Technical difficulties encountered using the Very Wide Field Camera (VWFC) during the Spacelab 1 Shuttle mission are reported. The VWFC is a wide low resolution (5 arcmin half-half width) photographic camera, capable of operating in both spectrometric and photometric modes. The bandpasses of the photometric mode of the VWFC are defined by three Al + MgF2 interference filters. A piggy-back spectrograph attached to the VWFC was used for observations in the spectrometric mode. A total of 48 astronomical frames were obtained using the VWFC, of which only 20 were considered to be of adequate quality for astronomical data processing. Preliminary analysis of the 28 poor-quality images revealed the following possible defects in the VWFC: darkness in the spacing frames, twilight/dawn UV straylight, and internal UV straylight. Improvements in the VWFC astronomical data processing scheme are expected to help identify and eliminate UV straylight sources in the future.

Viton, M.

High-accuracy global time and frequency transfer with a space-borne hydrogen maser clock

A proposed system for high-accuracy global time and frequency transfer using a hydrogen maser clock in a space vehicle is discussed. Direct frequency transfer with a accuracy of 10 to the minus 14th power and time transfer with an estimated accuracy of 1 nsec are provided by a 3-link microwave system. A short pulse laser system is included for subnanosecond time transfer and system calibration. The results of studies including operational aspects, error sources, data flow, system configuration, and implementation requirements for an initial demonstration experiment using the Space Shuttle are discussed.

Decher, R.

Gravitational waves and red shifts - A space experiment for testing relativistic gravity using multiple time-correlated radio signals

A two-step satellite mission for improving the accuracy of gravitational wave detection and for observing actual gravity waveforms is proposed. The spacecraft would carry both a highly stable hydrogen maser, which would control a transmitter sending signals to earth, and a Doppler transponder operating in the two-way mode. The use of simultaneous one- and two-way Doppler transmissions offers four time records of frequency pulsations, which can reveal gravitational radiation at 1-10 MHz with an amplitude accuracy of a factor of six. The first mission phase would consist of a Shuttle launch into a highly eccentric orbit to obtain measurements of the gravitational redshift using gravitational potentials of different earth regions to establish that gravity is describable by a metric theory. Then, after a boost into a heliocentric orbit at 6 AU, the earth-satellite system could detect gravitational waves in the solar system, as well as bursts emitted by the collisions of supermassive black holes.

Smarr, L. L.

Shuttle experiment to demonstrate high-accuracy global time and frequency transfer

The concept of a high-accuracy global time and frequency transfer system is discussed. A hydrogen maser clock onboard a space vehicle combined with a microwave Doppler cancellation system can provide direct frequency transfer with an accuracy of 10 to the -14th and time transfer accurate to 1 ns. The addition of short pulse laser techniques provides subnanosecond time transfer accuracy which can be used to calibrate the microwave system.

Allan, D. W.

A space system for high-accuracy global time and frequency comparison of clocks

A Space Shuttle experiment in which a hydrogen maser clock on board the Space Shuttle will be compared with clocks on the ground using two-way microwave and short pulse laser signals is described. The accuracy goal for the experiment is 1 nsec or better for the time transfer and 10 to the minus 14th power for the frequency comparison. A direct frequency comparison of primary standards at the 10 to the minus 14th power accuracy level is a unique feature of the proposed system. Both time and frequency transfer will be accomplished by microwave transmission, while the laser signals provide calibration of the system as well as subnanosecond time transfer.

Decher, R.

Test of relativistic gravitation with a space-borne hydrogen maser

The results of a test of general relativity with use of a hydrogen-maser frequency standard in a spacecraft launched nearly vertically upward to 10,000 km are reported. The agreement of the observed relativistic frequency shift with prediction is at the 70 x 10 to the -6th level.

Vessot, R. F. C.

Shuttle time and frequency transfer experiment

A proposed space shuttle experiment to demonstrate techniques for global high precision comparison of clocks and primary frequency standards is described. The experiment, using transmitted microwave and pulsed laser signals, compared a hydrogen maser clock onboard the space shuttle with a clock in a ground station in order to demonstrate time transfer with accuracies of 1 nsec or better and frequency comparison at the 10 to the -14th power accuracy level.

Allan, D. W.

Design aspects of a laser gravitational wave detector in space

Certain optical and mechanical aspects of a proposed laser gravitational wave antenna in space are briefly discussed. The proposed concept consists of a free-mass antenna with the test masses separated by a distance of 1,000,000 km. A laser heterodyne technique is employed to measure the distance change between test masses resulting from gravitational wave interaction. The proposed scheme is considered to offer the necessary sensitivity to detect gravitational radiation from binary stars predicted by General Relativity Theory.

Decher, R.

An Induced Environment Contamination Monitor for the Space Shuttle

The Induced Environment Contamination Monitor (IECM), a set of ten instruments integrated into a self-contained unit and scheduled to fly on shuttle Orbital Flight Tests 1 through 6 and on Spacelabs 1 and 2, is described. The IECM is designed to measure the actual environment to determine whether the strict controls placed on the shuttle system have solved the contamination problem. Measurements are taken during prelaunch, ascent, on-orbit, descent, and postlanding. The on-orbit measurements are molecular return flux, background spectral intensity, molecular deposition, and optical surface effects. During the other mission phases dew point, humidity, aerosol content, and trace gas are measured as well as optical surface effects and molecular deposition. The IECM systems and thermal design are discussed. Preflight and ground operations are presented together with associated ground support equipment. Flight operations and data reduction plans are given.

Miller, E. R.

High temperature solar photon engines

High temperature heat engines designed to make maximum use of the thermodynamic potential of concentrated solar radiation are described. Plasmas between 2000 K and 4000 K can be achieved by volumetric absorption of radiation in alkali metal vapors, leading to thermal efficiencies up to 75% for terrestrial solar power plants and up to 50% for space power plants. Two machines capable of expanding hot plasmas using practical technology are discussed. A binary Rankine cycle uses fluid mechanical energy transfer in a device known as the 'Comprex' or 'energy exchanger.' The second machine utilizes magnetohydrodynamics in a Brayton cycle for space applications. Absorption of solar energy and plasma radiation losses are investigated for a solar superheater using potassium vapor.

Hertzberg, A.

MHD conversion of solar energy

Low temperature plasmas wherein an alkali metal vapor is a component are uniquely suited to simultaneously absorb solar radiation by coupling to the resonance lines and produce electrical power by the MHD interaction. This work is an examination of the possibility of developing space power systems which take advantage of concentrated solar power to produce electricity. It is shown that efficient cycles in which expansion work takes place at nearly constant top cycle temperature can be devised. The power density of the solar MHD generator is lower than that of conventional MHD generators because of the relatively high seed concentration required for radiation absorption and the lower flow velocity permitted to avoid total pressure losses due to heating.

Lau, C. V.

A preliminary discussion of gravitational physics experiments for the Spacelab era

An overview of past, present, and proposed future experiments in gravitational physics is given. These experiments are concerned with the measurement of relativistic gravity effects to test theories of gravitation. Certain experiments which could be performed on shuttle and Spacelab missions and the potential of Spacelab for gravitation physics research are discussed.

Decher, R.

High resolution frequency analysis techniques with application to the redshift experiment

High resolution frequency analysis methods, with application to the gravitational probe redshift experiment, are discussed. For this experiment a resolution of .00001 Hz is required to measure a slowly varying, low frequency signal of approximately 1 Hz. Major building blocks include fast Fourier transform, discrete Fourier transform, Lagrange interpolation, golden section search, and adaptive matched filter technique. Accuracy, resolution, and computer effort of these methods are investigated, including test runs on an IBM 360/65 computer.

Decher, R.

Gyroscope relativity experiment

A gyroscope test of general relativity theory is proposed. The basic ideas and hardware concepts conceived by the investigators to implement the experiment are discussed. The goal is to measure the extremely small relativistic precession of gyroscopes in an earth-orbiting satellite. The experiment hardware (cryogenic gyroscopes, a telescope and superconducting circuits) is enclosed in a liquid helium dewar. The experiment will operate in orbit for about one year.

Decher, R.

Energy conversion research

Design, operation, and evaluation of large, segmented electrode nonequilibrium magnetohydrodynamic generator