Search NASA⌕ Search

Engineering topics

Defelice, J. J.

Publications and source records attributed to Defelice, J. J..

A practical approach to helicopter internal noise prediction

A practical and well correlated procedure for predicting helicopter internal noise is presented. It accounts for the propagation of noise along multiple paths on an octave by octave basis. The method is sufficiently general to be applicable to conventional helicopters as well as other aircraft types, when the appropriate structural geometry, noise source strengths, and material acoustic properties are defined. A guide is provided for the prediction of various helicopter noise sources over a wide range of horsepower for use when measured data are not available. The method is applied to the prediction of the interior levels of the Civil Helicopter Research Aircraft (CHRA), both with and without soundproofing installed. Results include good correlation with measured levels and prediction of the speech interference level within 1.5 db at all conditions. A sample problem is also shown illustrating the use of the procedure. This example calculates the engine casing noise observed in the passenger cabin of the CHRA.

Levine, L. S.↗

Active transmission isolation/rotor loads measurement system

Modifications were incorporated into a helicopter active transmission isolation system to provide the capability of utilizing the system as a rotor force measuring device. These included; (1) isolator redesign to improve operation and minimize friction, (2) installation of pressure transducers in each isolator, and (3) load cells in series with each torque restraint link. Full scale vibration tests performed during this study on a CH-53A helicopter airframe verified that these modifications do not degrade the systems wide band isolation characteristics. Bench tests performed on each isolator unit indicated that steady and transient loads can be measured to within 1 percent of applied load. Individual isolator vibratory load measurement accuracy was determined to be 4 percent. Load measurement accuracy was found to be independent of variations in all basic isolator operating characteristics. Full scale system load calibration tests on the CH-53A airframe established the feasibility of simultaneously providing wide band vibration isolation and accurate measurement of rotor loads. Principal rotor loads (lift, propulsive force, and torque) were measured to within 2 percent of applied load.

Kenigsberg, I. J.↗