Defoor, D

Publications and source records attributed to Defoor, D.

SU-F-T-233: Evaluation of Treatment Delivery Parameters Using High Resolution ELEKTA Log Files

Purpose: As modern linacs have become more technologically advanced with the implementation of IGRT and IMRT with HDMLCs, a requirement for more elaborate tracking techniques to monitor components’ integrity is paramount. ElektaLog files are generated every 40 milliseconds, which can be analyzed to track subtle changes and provide another aspect of quality assurance. This allows for constant monitoring of fraction consistency in addition to machine reliability. With this in mind, it was the aim of the study to evaluate if ElektaLog files can be utilized for linac consistency QA. Methods: ElektaLogs were reviewed for 16 IMRT patient plans with >16 fractions. Logs were analyzed by creating fluence maps from recorded values of MLC locations, jaw locations, and dose per unit time. Fluence maps were then utilized to calculate a 2D gamma index with a 2%–2mm criteria for each fraction. ElektaLogs were also used to analyze positional errors for MLC leaves and jaws, which were used to compute an overall error for the MLC banks, Y-jaws, and X-jaws by taking the root-meansquare value of the individual recorded errors during treatment. Additionally, beam on time was calculated using the number of ElektaLog file entries within the file. Results: The average 2D gamma for all 16 patient plans was found to be 98.0±2.0%. Recorded gamma index values showed an acceptable correlation between fractions. Average RMS values for MLC leaves and the jaws resulted in a leaf variation of roughly 0.3±0.08 mm and jaw variation of about 0.15±0.04 mm, both of which fall within clinical tolerances. Conclusion: The use of ElektaLog files for day-to-day evaluation of linac integrity and patient QA can be utilized to allow for reliable analysis of system accuracy and performance.

60 APPLIED LIFE SCIENCES↗

SU-F-T-458: Tracking Trends of TG-142 Parameters Via Analysis of Data Recorded by 2D Chamber Array

Purpose: With increasing QA demands of medical physicists in clinical radiation oncology, the need for an effective method of tracking clinical data has become paramount. A tool was produced which scans through data automatically recorded by a 2D chamber array and extracts relevant information recommended by TG-142. Using this extracted information a timely and comprehensive analysis of QA parameters can be easily performed enabling efficient monthly checks on multiple linear accelerators simultaneously. Methods: A PTW STARCHECK chamber array was used to record several months of beam outputs from two Varian 2100 series linear accelerators and a Varian NovalisTx−. In conjunction with the chamber array, a beam quality phantom was used to simultaneously to determine beam quality. A minimalist GUI was created in MatLab that allows a user to set the file path of the data for each modality to be analyzed. These file paths are recorded to a MatLab structure and then subsequently accessed by a script written in Python (version 3.5.1) which then extracts values required to perform monthly checks as outlined by recommendations from TG-142. The script incorporates calculations to determine if the values recorded by the chamber array fall within an acceptable threshold. Results: Values obtained by the script are written to a spreadsheet where results can be easily viewed and annotated with a “pass” or “fail” and saved for further analysis. In addition to creating a new scheme for reviewing monthly checks, this application allows for able to succinctly store data for follow up analysis. Conclusion: By utilizing this tool, parameters recommended by TG-142 for multiple linear accelerators can be rapidly obtained and analyzed which can be used for evaluation of monthly checks.

61 RADIATION PROTECTION AND DOSIMETRY↗

SU-F-T-465: Two Years of Radiotherapy Treatments Analyzed Through MLC Log Files

Purpose: To present treatment statistics of a Varian Novalis Tx using more than 90,000 Varian Dynalog files collected over the past 2 years. Methods: Varian Dynalog files are recorded for every patient treated on our Varian Novalis Tx. The files are collected and analyzed daily to check interfraction agreement of treatment deliveries. This is accomplished by creating fluence maps from the data contained in the Dynalog files. From the Dynalog files we have also compiled statistics for treatment delivery times, MLC errors, gantry errors and collimator errors. Results: The mean treatment time for VMAT patients was 153 ± 86 seconds while the mean treatment time for step & shoot was 256 ± 149 seconds. Patient’s treatment times showed a variation of 0.4% over there treatment course for VMAT and 0.5% for step & shoot. The average field sizes were 40 cm2 and 26 cm2 for VMAT and step & shoot respectively. VMAT beams contained and average overall leaf travel of 34.17 meters and step & shoot beams averaged less than half of that at 15.93 meters. When comparing planned and delivered fluence maps generated using the Dynalog files VMAT plans showed an average gamma passing percentage of 99.85 ± 0.47. Step & shoot plans showed an average gamma passing percentage of 97.04 ± 0.04. 5.3% of beams contained an MLC error greater than 1 mm and 2.4% had an error greater than 2mm. The mean gantry speed for VMAT plans was 1.01 degrees/s with a maximum of 6.5 degrees/s. Conclusion: Varian Dynalog files are useful for monitoring machine performance treatment parameters. The Dynalog files have shown that the performance of the Novalis Tx is consistent over the course of a patients treatment with only slight variations in patient treatment times and a low rate of MLC errors.

60 APPLIED LIFE SCIENCES↗

SU-G-TeP1-14: SRS Dose Calculation Accuracy Comparison Between Pencil Beam and Monte Carlo Algorithms

Purpose: Stereotactic radiosurgery (SRS) outcomes are related to the delivered dose to the target and to surrounding tissue. We have commissioned a Monte Carlo based dose calculation algorithm to recalculated the delivered dose planned using pencil beam calculation dose engine. Methods: Twenty consecutive previously treated patients have been selected for this study. All plans were generated using the iPlan treatment planning system (TPS) and calculated using the pencil beam algorithm. Each patient plan consisted of 1 to 3 targets and treated using dynamically conformal arcs or intensity modulated beams. Multi-target treatments were delivered using multiple isocenters, one for each target. These plans were recalculated for the purpose of this study using a single isocenter. The CT image sets along with the plan, doses and structures were DICOM exported to Monaco TPS and the dose was recalculated using the same voxel resolution and monitor units. Benchmark data was also generated prior to patient calculations to assess the accuracy of the two TPS against measurements using a micro ionization chamber in solid water. Results: Good agreement, within −0.4% for Monaco and +2.2% for iPlan were observed for measurements in water phantom. Doses in patient geometry revealed up to 9.6% differences for single target plans and 9.3% for multiple-target-multiple-isocenter plans. The average dose differences for multi-target-single-isocenter plans were approximately 1.4%. Similar differences were observed for the OARs and integral dose. Conclusion: Accuracy of the beam is crucial for the dose calculation especially in the case of small fields such as those used in SRS treatments. A superior dose calculation algorithm such as Monte Carlo, with properly commissioned beam models, which is unaffected by the lack of electronic equilibrium should be preferred for the calculation of small fields to improve accuracy.

60 APPLIED LIFE SCIENCES↗

SU-G-TeP4-13: Interfraction Treatment Monitoring Using Integrated Invivo EPID Images

Purpose: To investigate inter-fraction differences of dose delivery by analyzing portal images acquired during treatment and implement an automated system to generate a report for each fraction. Large differences in images between fractions can alert the physicist of possible machine performance issues or patient set-up errors. Methods: A Varian Novalis Tx equipped with a HD120 MLC and aS1000 electronic portal imaging device (EPID) was used in our study. EPID images are acquired in continuous acquisition mode for 32 volumetric arc therapy (VMAT) patients. The images are summed to create an image for each arc and a single image for each fraction. The first fraction is designated as the reference unless a machine error prevented acquisition of all images. The images for each beam as well as the fraction image are compared using gamma analysis at 1%/1mm, 2%/2mm and 3%/3mm. A report is then generated using an in house MatLab program containing the comparison for the current fraction as well as a history of previous fractions. The reports are automatically sent via email to the physicist for review. Fractions in which the total number of images was not within 5% of the reference number of images were not included in the results. Results: 91 of the 182 fractions recorded an image count within 5% of the reference. Gamma averages over all fractions and patients were 96.2% ±0.8% at 3%/3mm, 92.9% ±1% at 2%/2mm and 80.6% ±1.8% at 1%/1mm. The SD between fractions for each patient ranged from .004% to 10.4%. Of the 91 fractions 3 flagged due to low gamma values. After further investigation no significant errors were found. Conclusion: This toolkit can be used for in-vivo monitoring of treatment plan delivery an alert the physics staff of any inter-fraction discrepancies that may require further investigation.

60 APPLIED LIFE SCIENCES↗

SU-E-E-02: An Excel-Based Study Tool for ABR-Style Exams

Purpose: As the landscape of learning and testing shifts toward a computer-based environment, a replacement for paper-based methods of studying is desirable. Using Microsoft Excel, a study tool was developed that allows the user to populate multiple-choice questions and then generate an interactive quiz session to answer them. Methods: The code for the tool was written using Microsoft Excel Visual Basic for Applications with the intent that this tool could be implemented by any institution with Excel. The base tool is a template with a setup macro, which builds out the structure based on user’s input. Once the framework is built, the user can input sets of multiple-choice questions, answer choices, and even add figures. The tool can be run in random-question or sequential-question mode for single or multiple courses of study. The interactive session allows the user to select answer choices and immediate feedback is provided. Once the user is finished studying, the tool records the day’s progress by reporting progress statistics useful for trending. Results: Six doctoral students at UTHSCSA have used this tool for the past two months to study for their qualifying exam, which is similar in format and content to the American Board of Radiology (ABR) Therapeutic Part II exam. The students collaborated to create a repository of questions, met weekly to go over these questions, and then used the tool to prepare for their exam. Conclusion: The study tool has provided an effective and efficient way for students to collaborate and be held accountable for exam preparation. The ease of use and familiarity of Excel are important factors for the tool’s use. There are software packages to create similar question banks, but this study tool has no additional cost for those that already have Excel. The study tool will be made openly available.

97 MATHEMATICS AND COMPUTING↗

SU-E-T-363: Error Detection Comparison of EPID and MLC Log File Based IMRT QA Systems

Purpose: In this study we will compare the ability of three QA methods (Delta4, MU-EPID, Dynalog QA) to detect specific errors. Methods: A Varian Novalis Tx with a HD120 MLC and aS1000 Electronic Portal Imaging Device (EPID) was used in our study. Multi-leaf collimator (MLC) errors, gantry angle and dose errors were introduced into 5 volumetric arc therapy (VMAT) plans. 3D dose distributions calculated with data from the EPID and Dynalog QA methods were compared with the planned dose distribution. The gamma passing percentages as well as percentage error of planning target volume (PTV) dose were used for passing determination. Baselines for gamma passing percentages and PTV dose were established by measuring the original plan 5 times consecutively. Standard passing thresholds as well as thresholds derived from receiver operator characteristic (ROC) analysis and 2 standard deviation (SD) criteria were used. Results: When applying the standard 95% pass rate at 3%/3mm gamma analysis 14, 21 and 8 of 30 errors were detected by the Delta4, MU-EPID and Dynalog QA methods respectively. Thresholds set at 2 SD from our base line measurements resulted in the detection of 18, 9 and 14 of 30 errors for the Delta4, MU-EPID and Dynalog QA methods respectively. When using D2 of the PTV as a metric the Dynalog QA detected 20 of 30 errors while the EPID method detected 14 of 30 errors. Using D98 of the PTV, Dynalog QA detected 13 of 30 while the EPID detected 3 of 30 errors. Conclusion: Although MU-EPID detected the most errors at the standard 95% cutoff it also produced the most false detections in the baseline data. The Dynalog QA was the most effective when the ROC adjusted passing threshold was used. D2 was more effective as a metric for detecting errors than D98.

60 APPLIED LIFE SCIENCES↗

SU-E-T-545: MLC Distance Travelled as a Predictor for Motor Failure

Purpose: To study the frequency of Multi-Leaf Collimator (MLC) leaf failures, investigate methods to predict them and reduce linac downtime. Methods: A Varian HD120 MLC was used in our study. The hyperterminal MLC errors logged from 06/2012 to 12/2014 were collected. Along with the hyperterminal errors, the MLC motor changes and all other MLC interventions by the linear accelerator engineer were recorded. The MLC dynalog files were also recorded on a daily basis for each treatment and during linac QA. The dynalog files were analyzed to calculate root mean square errors (RMS) and cumulative MLC travel distance per motor. An in-house MatLab code was used to analyze all dynalog files, record RMS errors and calculate the distance each MLC traveled per day. Results: A total of 269 interventions were recorded over a period of 18 months. Of these, 146 included MLC motor leaf change, 39 T-nut replacements, and 84 MLC cleaning sessions. Leaves close to the middle of each side required the most maintenance. In the A bank, leaves A27 to A40 recorded 73% of all interventions, while the same leaves in the B bank counted for 52% of the interventions. On average, leaves in the middle of the bank had their motors changed approximately every 1500m of travel. Finally, it was found that the number of RMS errors increased prior to an MLC motor change. Conclusion: An MLC dynalog file analysis software was developed that can be used to log daily MLC usage. Our eighteen-month data analysis showed that there is a correlation between the distance an MLC travels, the RMS and the life of the MLC motor. We plan to use this tool to predict MLC motor failures and with proper and timely intervention, reduce the downtime of the linac during clinical hours.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

SU-E-T-784: Using MLC Log Files for Daily IMRT Delivery Verification

Purpose: To verify daily intensity modulated radiation therapy (IMRT) treatments using multi-leaf collimator (MLC) log files. Methods: The MLC log files from a NovalisTX Varian linear accelerator were used in this study. The MLC files were recorded daily for all patients undergoing IMRT or volumetric modulated arc therapy (VMAT). The first record of each patient was used as reference and all records for subsequent days were compared against the reference. An in house MATLAB software code was used for the comparisons. Each MLC log file was converted to a fluence map (FM) and a gamma index (γ) analysis was used for the evaluation of each daily delivery for every patient. The tolerance for the gamma index was set to 2% dose difference and 2mm distance to agreement while points with signal of 10% or lower of the maximum value were excluded from the comparisons. Results: The γ between each of the reference FMs and the consecutive daily fraction FMs had an average value of 99.1% (ranged from 98.2 to 100.0%). The FM images were reconstructed at various resolutions in order to study the effect of the resolution on the γ and at the same time reduce the time for processing the images. We found that the comparison of images with the highest resolution (768×1024) yielded on average a lower γ (99.1%) than the ones with low resolution (192×256) (γ 99.5%). Conclusion: We developed an in-house software that allows us to monitor the quality of daily IMRT and VMAT treatment deliveries using information from the MLC log files of the linear accelerator. The information can be analyzed and evaluated as early as after the completion of each daily treatment. Such tool can be valuable to assess the effect of MLC positioning on plan quality, especially in the context of adaptive radiotherapy.

60 APPLIED LIFE SCIENCES↗

SU-E-T-252: On the Evaluation of Patient Specific IMRT QA Using EPID, Dynalog Files and Patient Anatomy

Purpose: This research, investigates the viability of using the Electronic portal imaging device (EPID) coupled with the treatment planning system (TPS), to calculate the doses delivered and verify agreement with the treatment plan. The results of QA analysis using the EPID, Delta4 and fluence calculations using the multi-leaf collimator (MLC) dynalog files on 10 IMRT patients are presented in this study. Methods: EPID Fluence Images in integrated mode and Dynalog files for each field were acquired for 10 IMRT (6MV) patients and processed through an in house MatLab program to create an opening density matrix (ODM) which was used as the input fluence for dose calculation with the TPS (Pinnacle3, Philips). The EPID used in this study was the aSi1000 Varian on a Novalis TX linac equipped with high definition MLC. The resulting dose distributions were then exported to VeriSoft (PTW) where a 3D gamma was calculated using 3mm-3% criteria. The Scandidos Delta4 phantom was also used to measure a 2D dose distribution for all 10 patients and a 2D gamma was calculated for each patient using the Delta4 software. Results: The average 3D gamma for all 10 patients using the EPID images was 98.2% ± 2.6%. The average 3D gamma using the dynalog files was 94.6% ± 4.9%. The average 2D gamma from the Delta4 was 98.1% ± 2.5%. The minimum 3D gamma for the EPID and dynalog reconstructed dose distributions was found on the same patient which had a very large PTV, requiring the jaws to open to the maximum field size. Conclusion: Use of the EPID, combined with a TPS is a viable method for QA of IMRT plans. A larger ODM size can be implemented to accommodate larger field sizes. An adaptation of this process to Volumetric Arc Therapy (VMAT) is currently under way.

60 APPLIED LIFE SCIENCES↗

SU-E-T-576: Evaluation of Patient Specific VMAT QA Using Dynalog Files and Treatment Planning System

Purpose: This research investigates the use of Mult-ileaf Collimator (MLC) dynalog files to modify a Volumetric Arc Therapy (VMAT) DICOM Radiotherapy Treatment file from the Treatment Planning System (TPS) for quality assurance and treatment plan verification. Methods: Actual MLC positions and gantry angles where retrieved from the MLC Dynalog files of an approved and treated VMAT plan. The treatment machine used was a Novalis TX linac equipped with high definition MLC. The DICOM RT file of the plan was exported from the TPS (Eclipse, Varian Medical Systems) and the actual MLC leaf positions and gantry angles were inserted in place of the planned positions for each control point. The modified DICOM RT file was then imported back into the TPS where dose calculations were performed. The resulting dose distributions were then exported to VeriSoft (PTW) where a 3D gamma was calculated using 3mm-3% and 2mm-2% criteria. A 2D gamma was also calculated using dose measurements on the Delta4 (Sandidose) phantom. Results: A 3D gamma was calculated in Verisoft at 3mm-3% of 99.5% and at 2mm-2% of 99.2%. The pretreatment verification on the Delta4 yielded a 2D gamma at 3mm-3% of 97.9% and at 2mm-2% of 88.5%. The dose volume histograms of the approved plan and the dynalog plan are virtually identical. Conclusion: Initial results show good agreement of the dynalog dose distribution with the approved plan. Future work on this research will aim to increase the number of patients and replace the planned fractionated dose per control point with the actual fractionated dose.

07 ISOTOPE AND RADIATION SOURCES↗