Search NASASearch

Engineering topics

Delfino, Jana G.

Publications and source records attributed to Delfino, Jana G..

Applying queueing theory to evaluate wait-time-savings of triage algorithms

Abstract In the past decade, artificial intelligence (AI) algorithms have made promising impacts in many areas of healthcare. One application is AI-enabled prioritization software known as computer-aided triage and notification (CADt). This type of software as a medical device is intended to prioritize reviews of radiological images with time-sensitive findings, thus shortening the waiting time for patients with these findings. While many CADt devices have been deployed into clinical workflows and have been shown to improve patient treatment and clinical outcomes, quantitative methods to evaluate the wait-time-savings from their deployment are not yet available. In this paper, we apply queueing theory methods to evaluate the wait-time-savings of a CADt by calculating the average waiting time per patient image without and with a CADt device being deployed. We study two workflow models with one or multiple radiologists (servers) for a range of AI diagnostic performances, radiologist’s reading rates, and patient image (customer) arrival rates. To evaluate the time-saving performance of a CADt, we use the difference in the mean waiting time between the diseased patient images in the with-CADt scenario and that in the without-CADt scenario as our performance metric. As part of this effort, we have developed and also share a software tool to simulate the radiology workflow around medical image interpretation, to verify theoretical results, and to provide confidence intervals for the performance metric we defined. We show quantitatively that a CADt triage device is more effective in a busy, short-staffed reading setting, which is consistent with our clinical intuition and simulation results. Although this work is motivated by the need for evaluating CADt devices, the evaluation methodology presented in this paper can be applied to assess the time-saving performance of other types of algorithms that prioritize a subset of customers based on binary outputs.

Thompson, Yee Lam Elim (ORCID:0000000196537707)

Out-of-Distribution Detection and Radiological Data Monitoring Using Statistical Process Control

Abstract Machine learning (ML) models often fail with data that deviates from their training distribution. This is a significant concern for ML-enabled devices as data drift may lead to unexpected performance. This work introduces a new framework for out of distribution (OOD) detection and data drift monitoring that combines ML and geometric methods with statistical process control (SPC). We investigated different design choices, including methods for extracting feature representations and drift quantification for OOD detection in individual images and as an approach for input data monitoring. We evaluated the framework for both identifying OOD images and demonstrating the ability to detect shifts in data streams over time. We demonstrated a proof-of-concept via the following tasks: 1) differentiating axial vs. non-axial CT images, 2) differentiating CXR vs. other radiographic imaging modalities, and 3) differentiating adult CXR vs. pediatric CXR. For the identification of individual OOD images, our framework achieved high sensitivity in detecting OOD inputs: 0.980 in CT, 0.984 in CXR, and 0.854 in pediatric CXR. Our framework is also adept at monitoring data streams and identifying the time a drift occurred. In our simulations tracking drift over time, it effectively detected a shift from CXR to non-CXR instantly, a transition from axial to non-axial CT within few days, and a drift from adult to pediatric CXRs within a day—all while maintaining a low false positive rate. Through additional experiments, we demonstrate the framework is modality-agnostic and independent from the underlying model structure, making it highly customizable for specific applications and broadly applicable across different imaging modalities and deployed ML models.

Zamzmi, Ghada

Evaluating Machine Learning-Based MRI Reconstruction Using Digital Image Quality Phantoms

Quantitative and objective evaluation tools are essential for assessing the performance of machine learning (ML)-based magnetic resonance imaging (MRI) reconstruction methods. However, the commonly used fidelity metrics, such as mean squared error (MSE), structural similarity (SSIM), and peak signal-to-noise ratio (PSNR), often fail to capture fundamental and clinically relevant MR image quality aspects. To address this, we propose evaluation of ML-based MRI reconstruction using digital image quality phantoms and automated evaluation methods. Our phantoms are based upon the American College of Radiology (ACR) large physical phantom but created in k-space to simulate their MR images, and they can vary in object size, signal-to-noise ratio, resolution, and image contrast. Our evaluation pipeline incorporates evaluation metrics of geometric accuracy, intensity uniformity, percentage ghosting, sharpness, signal-to-noise ratio, resolution, and low-contrast detectability. We demonstrate the utility of our proposed pipeline by assessing an example ML-based reconstruction model across various training and testing scenarios. The performance results indicate that training data acquired with a lower undersampling factor and coils of larger anatomical coverage yield a better performing model. The comprehensive and standardized pipeline introduced in this study can help to facilitate a better understanding of the performance and guide future development and advancement of ML-based reconstruction algorithms.

47 OTHER INSTRUMENTATION