BEST Field Degradation Research

Data for control and 5-year fielded bifacial modules of PERC and SHJ technologies, including IV Curves, EQE, EL and PL, for degradation and performance studies.

14 SOLAR ENERGY↗

PV Lifetime Project (2024 NREL Annual Report)

DOE’s PV Lifetime project was initiated in 2016 with the goal of accurately characterizing the early-life evolution of photovoltaic (PV) field performance. Different PV cell and module technologies result in different initial degradation rates due to effects like light-induced degradation (LID) and light & elevated temperature-induced degradation (LeTID). To accurately characterize the initial field degradation of maximum power (Pmp) requires the use of high-accuracy indoor IV curve measurements at standard test conditions. Therefore, PV modules involved in this study are removed from the field once or twice per year and brought indoors for measurement under constant temperature and irradiance conditions.

14 SOLAR ENERGY↗

Artificial ground reflector size and position effects on energy yield and economics of single‐axis‐tracked bifacial photovoltaics

Abstract Artificial ground reflectors improve bifacial energy yield by increasing both front and rear‐incident irradiance. Studies have demonstrated an increase in energy yield due to the addition of artificial reflectors; however, they have not addressed the effect of varying reflector dimensions and placement on system performance and the impact of these parameters on the reflectors' financial viability. We studied the effect of high albedo (70% reflective) artificial reflectors on single‐axis‐tracked bifacial photovoltaic systems through ray‐trace modeling and field measurements. In the field, we tested a range of reflector configurations by varying reflector size and placement and demonstrated that reflectors increased daily energy yield up to 6.2% relative to natural albedo for PERC modules. To confirm the accuracy of our model, we compared modeled and measured power and found a root mean square error (RMSE) of 5.4% on an hourly basis. We modeled a typical meteorological year in Golden, Colorado, to demonstrate the effects of artificial reflectors under a wide range of operating conditions. Seventy percent reflective material can increase total incident irradiance by 1.9%–8.6% and total energy yield by 0.9%–4.5% annually after clipping is considered with a DC–AC ratio of 1.2. Clipping has a significant effect on reflector impact and must be included when assessing reflector viability because it reduces reflector energy gain. We calculated a maximum viable cost for these improvements of up to $2.50–4.60/m 2 , including both material and installation, in Golden. We expanded our analysis to cover a latitude range of 32–48°N and demonstrated that higher‐latitude installations with lower energy yield and higher diffuse irradiance content can support higher reflector costs. In both modeling and field tests, and for all locations, the ideal placement of the reflectors was found to be directly underneath the module due to the optimized rear irradiance increase.

14 SOLAR ENERGY↗

Availability and Performance Loss Factors for U.S. PV Fleet Systems

In the PV Fleet Performance Data Initiative, we partner with photovoltaic (PV) fleet owners to collect time-series PV production data and publish aggregated, anonymized results. This report is an update of our previous publications, specifically a FY 2021 performance index publication and a FY 2022 fleet degradation analysis. In this analysis, we have increased our data participants and system totals by around 10% to 8.5 GW and 24,000 separate inverter data channels. Four major analysis topics are considered in this report: Performance Index (PI) trends, PV system availability, soiling losses, and PV system degradation. Performance Index and inverter availability are assessed on a larger set of data from our FY 2021 report: 1,128 systems compared with 200 systems from before. The increased number of systems is due to an improved data quality methodology, as well as introducing new systems to the analysis. Overall results are similar to previously published values - overall inverter availability is low in the first six months of system performance before reaching steady-state by the end of the first year. Excluding this six-month startup period, system-level aggregated data shows a median (P50) system availability of 0.99 and a lower 10th percentile (P90) value of 0.95 (Figure ES-1). A dependence on system size is also demonstrated, with worse inverter availability results for larger PV systems. Causes of this effect are under investigation, but may be impacted by inverter size, which also show lower availability for larger inverter sizes. This report also investigates PI, correcting for degradation, soiling, snow, and availability. Following these corrections, the median system PI over its entire lifetime is 0.95. PI values reported here are approximately 3% lower than what we presented in our previous FY 2021 report. Soiling loss is assessed in a comprehensive way for the first time in this report. Results are presented using the COmbined Degradation and Soiling (CODS) method, as implemented in RdTools (v3.0.0a4). Soiling values are presented for 255 systems, which indicated irradiance-weighted soiling loss greater than 1%. The values have been published in an updated NREL soiling map at nrel.gov/pv/soiling.html. Finally, we investigated system degradation using three different data analysis techniques: conventional RdTools (year-on-year (YOY)), CODS, and Performance Loss Rate (PLR) analysis. Overall degradation results are consistent with our previous publications. Rerunning conventional RdTools on our updated fleet shows that some data partners have systematically fallen below the median system degradation rate (change over time) of -0.75 %/year. A comparison with PLR analysis, which looks at change in annual PI over time, shows that median system degradation is consistent with -0.5% to -0.75% per year change. However, at the P90 value, system degradation is substantially faster. These two results are consistent and indicate that resulting degradation statistics depend to a great degree on the population of PV systems making up the analysis cohort and whether soiling impacts the systems. The use of CODS for degradation analysis provides a different method for degradation assessment, which explicitly excludes the impact of recoverable soiling on degradation analysis. Excluding soiling effects yields an annual system degradation around -0.5% per year on average. This indicates that a portion of system performance loss may be attributed to periodic soiling that is not fully recovered. This report provides PV system owners/operators with background and methods to analyze PV system performance, give guidance for expected cohort performance, and performance loss values for use in pro-forma financial models, which guide new-build system design and bankability reports.

14 SOLAR ENERGY↗

PV System Availability from Commercial and Utility-Scale Systems [Slides]

In the PV Fleet Performance Data Initiative, we partner with photovoltaic (PV) fleet owners to collect time-series PV production data, and publish aggregated, anonymized results. An assessment of system availability is conducted on 1128 systems which passed our data quality checks, and include cumulative energy meter data. Overall inverter availability is low in the first 6 months of system performance before reaching steady-state by the end of the first year. System-level aggregated data shows a median (P50) system availability of 0.99, and a lower P90 value of 0.95. A dependence on system size is also identified, with worse inverter availability results for larger PV systems. Potential causes of this effect are under investigation.

14 SOLAR ENERGY↗

Extreme Weather Impact on PV - Resilience Lessons for Long-Term Performance

Aside from the immediate, visible damage, extreme weather events have a longer lasting impact on PV systems. Here, NREL's Dirk C. Jordan, Kirsten Perry, Robert White, Josh Parker, Byron McDanold and Chris Deline report on research revealing the long-term consequences of hail, wind and other weather phenomena on PV production

14 SOLAR ENERGY↗