LCOE*: Re-Thinking LCOE for Photovoltaic Systems

Solar industry is working towards reducing the levelized cost of energy (LCOE). The LCOE formulation includes various implicitly connected cost and physical design parameters. This entails complex cost analyses by economists, and electrical analysis and energy yield calculations of solar farms by device physicists/technologists. The standard formulation requires a constant exchange of information to optimize the design of a specific farm. In this paper, we present a fundamental reformulation of LCOE (in terms of LCOE*) to deconvolve the cost vs. energy yield analysis so that economists and technologists can work independently towards minimizing LCOE. We validate our LCOE* formulation by comparing LCOE calculated by the traditional vs. new method. We further provide a global analysis of LCOE* as an illustrative example. This LCOE* will accelerate new technology development (e.g. bifacial PV) by allowing a rapid and transparent analysis of its cost-performance trade-off.

14 SOLAR ENERGY↗

PV Degradation - Mounting & Temperature

Several studies have found indications that PV degradation may increase in hotter climates. We show in this paper that degradation does correlate to higher module temperatures, but that these temperatures are significantly affected by the module mounting and. The mechanisms of degradation vary with module technology and quality. Using data from different HIT module installations we were able to extract an activation energy that is consistent with hydrogen passivation layer degradation. In addition, we show that low degradation in hot climates can be achieved for Al-BSF technology if properly installed to reduce heat transfer in order to thermally decouple the modules from the roof. We also found that monofacial and bifacial PERC module degradation is in line with historical degradation rates of Al-BSF.

14 SOLAR ENERGY↗

Field-Aging Test Bed for Behind-the-Meter PV + Energy Storage

Small DC-coupled battery test systems are deployed at the National Renewable Energy Laboratory to evaluate capacity fade models and report on performance parameters such as round-trip efficiency under indoor and outdoor deployment scenarios. Initial commercial battery products include LG Chem RESU lithium-ion (Li-ion) and Avalon vanadium redox flow batteries. Adapting indoor lab-scale test methods to outdoor systems has challenges, including maintaining constant temperature and fully controlling batteries through standard discharge curves. Initial measurements show the Li-ion battery systems performing within expectations, near 85% round-trip efficiency. Initial lifetime modeling and measurements indicate that battery capacity could degrade by 20%-35% over 10 years at current rates.

14 SOLAR ENERGY↗

Numerical Validation of an Algorithm for Combined Soiling and Degradation Analysis of Photovoltaic Systems

We describe and demonstrate an open-source algorithm for simultaneously quantifying degradation and soiling of photovoltaic (PV) systems from energy-production time series data. The new analysis is based on year-on-year degradation rate analysis combined with stochastic rate and recovery soiling analysis. The algorithm is designed to fit into the workflow provided by RdTools, a Python module maintained by NREL and collaboratively developed with the community, which provides a framework and functions for degradation and loss-factor analysis of PV field data. We demonstrate the method on numerically simulated PV data sets and show that it reduces the root-mean-square error of the P50 degradation rate estimate when soiling is present.

14 SOLAR ENERGY↗

Understanding Bifacial PV Modeling: Raytracing and View Factor Models

As part of the PV Magazine Webinar 'View-factor vs. ray tracing - which bifacial modelling techniques should you use?,' the second part lead by NREL will explore the different rear-irradiance calculation software, which fall into two categories: view-factor and ray-tracing models. View factor models assume isotropic scattering of reflected rays, allowing for calculation of irradiance by integration. Due-diligence software such as PVSyst or SAM use the view-factor model. Ray-tracing models simulate multipath reflection and absorption of individual rays entering a scene. Raytracing software such as bifacial_radiance, which is the only available open-source toolkit, offers the possibility of reproducing complex scenes, including shading or finite-system edge effects. This can be useful to evaluate specific system geometries, shading and obstructions, areas of different albedo and electrical mismatch, all topics of interest to the prediction of bifacial performance. Model agreement for view factors and bifacial_radiance software is improving and has been shown to be between 2% (absolute) when compared with measured results.

14 SOLAR ENERGY↗

Effect of Torque-Tube Parameters on Rear-Irradiance and Rear-Shading Loss for Bifacial PV Performance on Single-Axis Tracking Systems: Preprint

The emergence of cost-competitive bifacial PV modules has raised the question of the additional value of bifacial modules in 1-axis tracking arrays, in particular when considering rear-irradiance losses from the tracker system itself. In this work, the effect of different geometries and materials of torque tubes is evaluated and found to reduce rear-irradiance averages without any torque-tube shading by 0.1 to 12% for metallic and black absorptive torque tubes respectively for a clear-sky day. This paper will compare modeled to measured rear-irradiance profiles, and propose a recommended range of rear-shading loss factors for different geometry conditions. The effect of rear-irradiance distribution into electrical mismatch loss will also be explored.

14 SOLAR ENERGY↗

Bifacial Tracking Testbed at NREL

Bifacial demonstration plant with 10 rows of single-axis trackers. Each row is independently monitored and grid tied. This project continues our work on bifacial photovoltaic modeling, field evaluation and standards development.

14 SOLAR ENERGY↗

Suggested Modifications for Bifacial Capacity Testing: Preprint

Capacity tests such as those described in ASTM 2848 and IEC 61724-2 are widely used during the contracting and acceptance testing of PV systems. With the increasing deployment of bifacial PV modules, there is a need to develop a standardized approach to capacity test these systems. Although variability and bias error was inherently higher for the measured capacity of bifacial systems, it could be reduced to a level consistent with the monofacial reference system by appropriate incorporation of rear irradiance- either measured or modeled. Three field installations provided bifacial system capacity that was measured with a mean bias error and standard deviation within 1% over the 2-10 month observation period. Capacity test accuracy could be improved further by utilizing measured back-of-module temperature and the IEC 61724-2 test method.

14 SOLAR ENERGY↗

Bifacial PV System Mismatch Loss Estimation and Parameterization: Preprint

Non-uniform irradiance on the rear-side of bifacial PV systems can cause additional mismatch loss which may not be appropriately captured in PV energy production estimates and software. We have evaluated several scenarios including horizontal single-axis tracking (HSAT) and rooftop mounted systems over high albedo reflective roofs. Mismatch losses of up to 2% annual loss for very close-mounted (0.15 m) rooftop systems were found, but losses for HSAT systems and high ground-clearance rooftop systems were lower (<0.5%). A simplified empirical relationship was found that links the spatial variation of irradiance (specifically the mean absolute difference of irradiance) to the resulting mismatch loss factor, with a R2 fit better than 0.985. This approximate relationship has been validated by experiments on mismatched PV modules, and provides a basis for fast estimation of bifacial mismatch loss factors for use in hourly PV performance simulations such as PVSyst or SAM.

14 SOLAR ENERGY↗

Bifacial PV Performance Models: Comparison and Field Results

Updated performance models for bifacial PV are being developed at NREL. We are in the process of validating these optical models against field trial configurations, and commercial bifacial models. This presentation provides preliminary field test results, intercomparison of NREL's Ray Tracing and View Factor bifacial modules against PVSyst, and a SolarWorld empirical model. Some specific attributes of bifacial modeling are addressed including edge effects and rear irradiance non-uniformity / mismatch loss.

14 SOLAR ENERGY↗

Single-Axis Tracked Bifacial System Results

Results of a study on single-axis tracked bifacial PV in Klamath Falls, Oregon. Includes the adaptive tracking angle, edge brightening, and torque tube shading.

14 SOLAR ENERGY↗

The 1st International Round-Robin on Bi-Facial Modules

This presentation discusses validation of methods and ensuring the validity of results when testing bifacial PV modules, both of which are requirements in ISO/IEC 17025:2017; electrical parameters to be reported per IEC TS 60904-1-2; and statistical design proficiency testing per ISO 17043.

14 SOLAR ENERGY↗

Field Aging Testbed for Behind-the-Meter PV + Energy Storage

Small DC-coupled battery test systems are deployed at NREL to evaluate capacity fade models and report on performance parameters such as round-trip efficiency under indoor and outdoor deployment scenarios. Initial commercial battery products include LG Chem RESU Lithium-ion and Avalon vanadium-redox flow batteries. Adapting indoor lab-scale test methods to outdoor systems has challenges, including maintaining constant temperature and fully controlling batteries through standard discharge curves. Initial measurements show the Lithium Ion battery systems performing within expectation, near 85% round-trip efficiency. Initial lifetime modeling and measurements indicate battery capacity may degrade by 20%-35% over 10 years.

25 ENERGY STORAGE↗

Bifacial PV System Mismatch Loss Estimation & Parameterization

Non-uniform irradiance on the rear-side of bifacial PV systems can cause additional mismatch loss which may not be appropriately captured in PV energy production estimates and software. We have evaluated several rooftop mounted systems over high albedo reflective roofs. Mismatch losses of up to 2% annual loss for very close-mounted (0.15 m) rooftop systems were found, but losses for high ground-clearance rooftop systems were lower (<0.5%). A simplified empirical relationship was found that links the spatial variation of irradiance (specifically the mean absolute difference of irradiance) to the resulting mismatch loss factor, with a R2 fit better than 0.985. This approximate relationship has been validated by experiments on mismatched PV modules, and provides a basis for fast estimation of bifacial mismatch loss factors for use in hourly PV performance simulations such as PVSyst or SAM.

14 SOLAR ENERGY↗

The Subtle Art of Bifacial Performance Modeling

The PV industry is set for rapid uptake of bifacial PV if key barriers are eliminated, such as accurate performance models, standards around the rating of bifacial modules, and accurate assessment of site albedo. In this presentation we will talk about the changes to the ray-trace program bifacial_radiance, it's new capabilities that allow it to model the performance for any module at any size array. A new graphical user interface has been released on time for this conference. Preliminary results for torque-tube shading are also presented.

14 SOLAR ENERGY↗

Bifacial PV System Mismatch Loss Estimation

Nonuniform rear-irradiance on bifacial PV systems can cause additional mismatch loss, which may not be appropriately captured in PV energy production estimates and software. A simplified empirical relationship is presented that links the spatial variation of irradiance (to the resulting mismatch loss factor).

14 SOLAR ENERGY↗

International Collaboration Framework for the Calculation of Performance Loss Rates: Data Quality, Benchmarks, and Trends

Within the IEA PVPS Task 13, a group of experts representing several leading R&D centres, universities and industry companies, is developing a framework for the calculation of Performance Loss Rates (PLR) on a large number of commercial and research PV power plants and related weather data coming from various climatic zones. Various methodologies are applied for the calculation of PLR which are benchmarked in terms of uncertainties and 'true' values. The aim of the international collaboration is to show how to calculate the PLR on high quality (high time resolution, reliable data, irradiance, yield, etc.) and on low quality data (low time resolution, only energy data available). Various algorithms and models, along with different time averaging and filtering criteria, can be applied for the calculation of PLR each of which can have an impact on the results. The approach considers three pathways to ensure broad collaboration and increase the statistical relevance of the study: i) use of shared methodologies on shared time series, ii) use of confidential methodologies on shared time series, iii) use of shared methodologies on confidential time series. The data is used for benchmarking activities and to define which methodologies clusters around a 'true value' of PLR. The combination of metrics (PR or power based) and methodologies are benchmarked in terms of deviation from the average value and in terms of standard deviation. The combination of temperature corrected PR with the use of Year on Year (YOY) or Seasonal Trend decomposition using Loess (STL) performs well for all systems; other methodologies seems to be more depending on the filtering applied. Another set of data is represented by the IEA PVPS Task 13 'PV performance database' which includes more than 120 PV plants from different climates. The applied methodologies were STL and the YoY approach. STL results in an averaged PLR over all systems of -0.78%/a while YoY yields -0.63%/a. STL is better suited if the time series data are of higher resolution and high-quality weather data are available. One important outcome of this study is the setting of a framework for the contribution to a clear and structured quality classification for PV time series data and a guideline for PLR calculations in dependency of the data categorization.

14 SOLAR ENERGY↗

Effect of Torque-Tube Parameters on Rear-Irradiance and Rear-Shading Loss for Bifacial PV Performance on 1-Axis Tracking Systems

The emergence of cost-competitive bifacial PV modules has raised the question of the additional value of bifacial modules in 1-axis tracking arrays, in particular when considering rear-irradiance losses from the tracker system itself. In this work, the effect of different geometries and materials of torque tubes is evaluated and found to reduce rear-irradiance averages without any torque-tube shading by 0.1 to 12% for metallic and black absorptive torque tubes respectively for a clear-sky day. This paper will compare modeled to measured rear-irradiance profiles, and propose a recommended range of rear-shading loss factors for different geometry conditions. The effect of rear-irradiance distribution into electrical mismatch loss will also be explored. shading by 0.1 to 12% for metallic and black absorptive torque tubes respectively for a clear-sky day. This paper will compare modeled to measured rear-irradiance profiles, and propose a recommended range of rear-shading loss factors for different geometry conditions. The effect of rear-irradiance distribution into electrical mismatch loss will also be explored.

14 SOLAR ENERGY↗