Search NASA⌕ Search

Engineering topics

Delogu, Pasquale

Publications and source records attributed to Delogu, Pasquale.

Measurement of an inverse Compton scattering source local spectrum using k-edge filters

X-ray sources based on the inverse Compton scattering process are attracting a growing interest among scientists, due to their extremely fast pulse, quasi-monochromatic spectrum, and relatively high intensity. The energy spectrum of the x-ray beam produced by inverse Compton scattering sources in a fixed observation direction is a quasi-monochromatic approximately Gaussian distribution. The mean value of this distribution varies with the scattering polar angle between the electron beam direction and the x-ray beam observation direction. Previous works reported experimental measurements of the mean energy as a function of the polar angle. This work introduces a method for the measurement of the whole local energy spectrum (i.e., the spectrum in a fixed observation direction) of the x-ray beam yielded by inverse Compton scattering sources, based on a k-edge filtering technique.

07 ISOTOPE AND RADIATION SOURCES↗

Phase contrast imaging simulation and measurements using polychromatic sources with small source-object distances

Phase contrast imaging is a technique widely used in synchrotron facilities for nondestructive analysis. Such technique can also be implemented through microfocus x-ray tube systems. Recently, a relatively new type of compact, quasimonochromatic x-ray sources based on Compton backscattering has been proposed for phase contrast imaging applications. In order to plan a phase contrast imaging system setup, to evaluate the system performance and to choose the experimental parameters that optimize the image quality, it is important to have reliable software for phase contrast imaging simulation. Several software tools have been developed and tested against experimental measurements at synchrotron facilities devoted to phase contrast imaging. However, many approximations that are valid in such conditions (e.g., large source-object distance, small transverse size of the object, plane wave approximation, monochromatic beam, and Gaussian-shaped source focal spot) are not generally suitable for x-ray tubes and other compact systems. In this work we describe a general method for the simulation of phase contrast imaging using polychromatic sources based on a spherical wave description of the beam and on a double-Gaussian model of the source focal spot, we discuss the validity of some possible approximations, and we test the simulations against experimental measurements using a microfocus x-ray tube on three types of polymers (nylon, poly-ethylene-terephthalate, and poly-methyl-methacrylate) at varying source-object distance. It will be shown that, as long as all experimental conditions are described accurately in the simulations, the described method yields results that are in good agreement with experimental measurements.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗