Search NASA⌕ Search

Engineering topics

Demers, D. R.

Publications and source records attributed to Demers, D. R..

The Compelling Need for a Mid-Scale Stellarator Facility

In the pursuit of the goal of commercial fusion as an abundant and safe source of energy, the stellarator is a leading concept with compelling attractiveness and demonstrated performance. In this white paper we, as a community of US researchers from Universities, National Laboratories, and Private Industry, involved in studying the stellarator concept, lay out the programmatic and technical motivation for a new mid-size stellarator research facility in the US. This contribution is complementary to several other whitepapers authored by members of our community which address different mid-scale stellarator aspects. A community based technical facility proposal has been prepared by F. Parra, et al: Flexible Stellarator Physics Facility. Two private stellarator companies have submitted proposals supporting the development of a mid-scale stellarator: Thea Energy (C.P.S. Swanson, et al.), Type One Energy (W. Guttenfelder, et al.).

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

The Compelling Need for a Mid-Scale Stellarator Facility

In the pursuit of the goal of commercial fusion as an abundant and safe source of energy, the stellarator is a leading concept with compelling attractiveness and demonstrated performance. A new mid-size stellarator is needed to retire risks and innovate towards a high performance, economically attractive, stellarator Fusion Pilot Plant. In this presentation we, as a community of US researchers from Universities, National Laboratories, and Private Industry, involved in studying the stellarator concept, lay out the programmatic and technical motivation for a new and modern mid-size stellarator research facility. A new mid-scale stellarator is needed to realize the potential predicted by a solid body of theory and simulation along with advances in computational tools for optimization and non-linear turbulence modeling. Notably, it is possible to combine the advantages of the stellarator (steady state, no current drive, no disruptions) with the good confinement regularly achieved in tokamaks. The top priorities for experimental work, and the motivation for a mid-scale stellarator experiment are: turbulence control, non-resonant divertor, MHD stability at large beta, confinement of fast particles, and coil simplification. A new mid-size quasi-symmetric stellarator, built as a user facility, would complement existing research at Wendelstein 7-X and LHD and strongly augment private industry. It would provide a program of innovative research, concept validation, theoretical advancement, and workforce development. Growing support and interest for stellarators by the fusion community and private industry affirms this rationale.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Conceptual design of a heavy ion beam probe diagnostic for the Wendelstein 7-X Stellarator

This article describes the current state of the design of the heavy ion beam probe (HIBP) for Wendelstein 7-X (W7-X). It will be the first HIBP diagnostic on an optimized stellarator and is designed to study electric fields and ion scale turbulence in all W7-X reference magnetic configurations. The use of an existing 2 MV accelerator, located outside of the torus hall, results in the need for a circuitous primary beamline. This increases the complexity of the ion optics design to deliver a focused beam to the plasma. To access most of the magnetic configuration space of W7-X, the secondary beamline and an energy analyzer are designed to pivot, thereby redirecting a wider range of secondary beam trajectories. Signal level estimates indicate that the equilibrium potential can be measured at all radii and that the radial coverage for potential and density fluctuations measurements depends on the plasma density.

47 OTHER INSTRUMENTATION↗

Improvement in the spatial resolution of heavy ion beam probe measurements through application of ion optics

A technique for more accurately modeling and improving the spatial resolution of heavy ion beam probe measurements is described. We use a set of particle trajectories to numerically determine the focusing properties of a complicated three-dimensional magnetic field and characterize those properties with a transfer matrix. We then modify the transfer matrix approach of traditional ion optics to include a parameter that describes the ionization location of the detected ions. The ion optics model calculated using this technique enables a more accurate description of the particle trajectories than previously feasible. The model also allows one to easily determine an initial beam focus that could be used during experimental operation to optimize the spatial resolution of measurements. The technique has been applied to the design of a heavy ion beam probe diagnostic for the Wendelstein 7-X stellarator and improvements in the modeled spatial resolution by a factor of about 2 over previous estimates are possible. As a result, the improved spatial resolution will enable measurements of plasma fluctuations with smaller wavelengths than would otherwise be possible.

43 PARTICLE ACCELERATORS↗

Noise mitigation methods for ion detectors operating with a direct view of high temperature plasmas

In this work, we have developed an ion current measurement instrument with a direct view of a plasma that reduces the particle and radiation-induced noise current it detects by over three orders of magnitude, from tens of microamps to tens of nanoamps. This is accomplished using electric fields, magnetic fields, and physical shielding that limit the flux of particles and radiation into the instrument and suppress the secondary electrons produced within it by particle and radiation impact. Operation of this detector in various configurations, without an ion beam, has allowed identification of the sources of noise current. In our experimental setup, the largest noise contributors were found to be plasma ions and photoelectric emission due to UV radiation.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Development of a beam ion velocity detector for the heavy ion beam probe

In an axisymmetric plasma, the conservation of canonical angular momentum constrains heavy ion beam probe (HIBP) trajectories such that measurement of the toroidal velocity component of secondary ions provides a localized determination of the poloidal flux at the volume where they originated. We have developed a prototype detector which is designed to determine the beam angle in one dimension through the detection of ion current landing on two parallel planes of detecting elements. A set of apertures creates a pattern of ion current on wires in the first plane and solid metal plates behind them; the relative amounts detected by the wires and plates determine the angle which beam ions enter the detector, which is used to infer the toroidal velocity component. The design evolved from a series of simulations within which we modeled ion beam velocity changes due to equilibrium and fluctuating magnetic fields, along with the ion beam profile and velocity dispersion, and studied how these and characteristics such as the size, cross section, and spacing of the detector elements affect performance.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Control of secondary electrons from ion beam impact using a positive potential electrode

Secondary electrons emitted when an ion beam impacts a detector can amplify the ion beam signal, but also introduce errors if electrons from one detector propagate to another. A potassium ion beam and a detector comprised of ten impact wires, four split-plates, and a pair of biased electrodes were used to demonstrate that a low-voltage, positive electrode can be used to maintain the beneficial amplification effect while greatly reducing the error introduced from the electrons traveling between detector elements.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Overview of results from the MST reversed field pinch experiment

An overview of recent results from the MST reversed field pinch programme is presented here. With neutral beam injection, bursty energetic particle (EP) modes are observed. The profiles of the magnetic and density fluctuations associated with these EP modes are measured using a far infrared interferometer–polarimeter. Equilibrium reconstructions of the quasi-single-helicity 3D helical state are provided by the V3FIT code that now incorporates several of MST's advanced diagnostics. The orientation of the helical structure is controlled using a new resonant magnetic perturbation technique. Gyrokinetic simulations based on experimental equilibria predict unstable trapped-electron modes (TEMs), and small-scale density fluctuations are detected in improved-confinement plasmas with TEM-like features. Upgraded pellet injection permits study of density and beta limits over MST's full range of operation, and an MST-record line-average density of 0.9 × 1020 m3 (n/nG = 1.4) has been obtained. Impurity ion temperature measurements reveal a charge-to-mass-ratio dependence in the rapid heating that occurs during a sawtooth crash. Runaway of NBI-born fast ions during the impulsive sawtooth event agrees with test-particle theory. Magnetic self-organization studies include measurements of the dynamo emf with an applied ac inductive electric field using oscillating field current drive.

beta limit↗

Resolving small signal measurements in experimental plasma environments using calibrated subtraction of noise signals

The performance of many diagnostic and control systems within fusion and other fields of research are often detrimentally affected by spurious noise signals. This is particularly true for those (such as radiation or particle detectors) working with very small signals. Common sources of radiated and conducted noise in experimental fusion environments include the plasma itself and instrumentation. The noise complicates data analysis, as illustrated by noise on signals measured with the heavy ion beam probe (HIBP) installed on the Madison Symmetric Torus. The noise is time-varying and often exceeds the secondary ion beam current (in contrast with previous applications). Analysis of the noise identifies the dominant source as photoelectric emission from the detectors induced by ultraviolet light from the plasma. This has led to the development of a calibrated subtraction technique, which largely removes the undesired temporal noise signals from data. The advantages of the technique for small signal measurement applications are demonstrated through improvements realized on HIBP fluctuation measurements.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Heavy ion beam probe advances from the first installation of the diagnostic on an RFP (invited)

Heavy ion beam probes have been installed on a variety of toroidal devices, but the first and only application on a reversed field pinch is the diagnostic on the Madison Symmetric Torus. Simultaneous measurements of spatially localized equilibrium potential and fluctuations of density and potential, previously inaccessible in the core of the reversed field pinch (RFP), are now attainable. These measurements reflect the unique strength of the heavy ion beam probe (HIBP) diagnostic. They will help determine the characteristics and evolution of electrostatic fluctuations and their role in transport, and determine the relation of the interior electric field and flows. Many aspects of the RFP present original challenges to HIBP operation and inference of plasma quantities. The magnetic field contributes to a number of the issues: the comparable magnitudes of the toroidal and poloidal fields and edge reversal result in highly three-dimensional beam trajectories; partial generation of the magnetic field by plasma current cause it and hence the beam trajectories to vary with time; and temporal topology and amplitude changes are common. Associated complications include strong ultraviolet radiation and elevated particle losses that can alter functionality of the electrostatic systems and generate noise on the detectors. These complexities have necessitated the development of new operation and data analysis techniques: the implementation of primary and secondary beamlines, adoption of alternative beam steering methods, development of higher precision electrostatic system models, refinement of trajectory calculations and sample volume modeling, establishment of stray particle and noise reduction methods, and formulation of alternative data analysis techniques. These innovative methods and the knowledge gained with this system are likely to translate to future HIBP operation on large scale stellarators and tokamaks.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Modular control of fusion power heating applications

This work is motivated by the growing demand for auxiliary heating on small and large machines worldwide. Numerous present and planned RF experiments (EBW, Lower Hybrid, ICRF, and ECH) are increasingly complex systems. The operational challenges are indicative of a need for components of real-time control that can be implemented with a moderate amount of effort in a time- and cost-effective fashion. Such a system will improve experimental efficiency, enhance experimental quality, and expedite technological advancements. The modular architecture of this control-suite serves multiple purposes. It facilitates construction on various scales from single to multiple controller systems. It enables expandability of control from basic to complex via the addition of modules with varying functionalities. It simplifies the control implementation process by reducing layers of software and electronic development. While conceived with fusion applications in mind, this suite has the potential to serve a broad range of scientific and industrial applications. During the Phase-I research effort we established the overall feasibility of this modular control-suite concept. We developed the fundamental modules needed to implement open-loop active-control and demonstrated their use on a microwave power deposition experiment.

42 ENGINEERING↗