Search NASA⌕ Search

Engineering topics

Demick, J.

Publications and source records attributed to Demick, J..

Measurement Protocols for In situ Analysis of Organic Compounds at Mars and Comets

The determination of the abundance and chemical and isotopic composition of organic molecules in comets and those that might be found in protected environments at Mars is a first step toward understanding prebiotic chemistries on these solar system bodies. While future sample return missions from Mars and comets will enable detailed chemical and isotopic analysis with a wide range of analytical techniques, precursor insitu investigations can complement these missions and facilitate the identification of optimal sites for sample return. Robust automated experiments that make efficient use of limited spacecraft power, mass, and data volume resources are required for use by insitu missions. Within these constraints we continue to explore a range of instrument techniques and measurement protocols that can maximize the return from such insitu investigations.

Mahaffy, P. R.↗

Cassini-Huygens Probe Gas Chromatograph Mass Spectrometer (GCMS) Experiment: First Results

The Huygens Probe of the Cassini Huygens Mission entered the atmosphere of the moon Titan on January 14, 2005. The GCMS was part of the instrument complement on the probe to measure in situ the chemical composition of the atmosphere during the probe descent and to support the Aerosol Collector Pyrolyzer (ACP) experiment by serving as detector for the pyrolization products. The GCMS collected data from an altitude of 146 km to ground impact for a time interval of 2hours and 37minutes. The Probe and the GCMS survived the ground impact and collected data for 1hour and 9 minutes on the surface in the near surface environment until signal loss by the orbiter. The major constituents of the lower atmosphere were found to be N2 and CH4. The methane-mixing ratio was found to increase below the turbopause, about 35 km altitude, monotonically toward the surface to levels near saturation. After surface impact a steep increase of the mixing ratio was observed suggesting evaporation of surface condensed methane due to heating by the GCMS sample inlet heater. Other constituents were found to be in very low concentrations, below ppm levels. The presence of Argon 40 was confirmed. The results for the other noble gases are still being evaluated. Other hydrocarbons and nitriles were also observed and quantitative evaluation is in progress. Preliminary ratios for the major carbon and nitrogen isotopes were computed from methane and molecular nitrogen measurements. The instrument collected 5634 mass spectra during descent and 2692 spectra on the ground over a range of m/z from 2 to 141. Eight gas chromatograph samples were taken during the descent and two on the ground.

Niemann, H.↗

Measurement Protocols for In Situ Analysis of Organic Compounds at Mars and Comets

The determination of the abundance and chemical and isotopic composition of organic molecules in comets and those that might be found in protected environments at Mars is a first step toward understanding prebiotic chemistries on these solar system bodies. While future sample return missions from Mars and comets will enable detailed chemical and isotopic analysis with a wide range of analytical techniques, precursor insitu investigations can complement these missions and facilitate the identification of optimal sites for sample return. Robust automated experiments that make efficient use of limited spacecraft power, mass, and data volume resources are required for use by insitu missions. Within these constraints we continue to explore a range of instrument techniques and measurement protocols that can maximize the return from such insitu investigations.

Mahaffy, P. R.↗

The Gas Chromatograph Mass Spectrometer (GCMS) Experiment on the Cassini-Huygens Probe: First Results

The Huygens Probe of the Cassini Huygens Mission entered the atmosphere of the moon Titan on January 14, 2005. The GCMS was part of the instrument complement on the Probe to measure in situ the chemical composition of the atmosphere during the probe descent and to support the Aerosol Collector Pyrolyzer (ACP) experiment by serving as detector for the pyrolization products. The GCMS collected data from an altitude of 146 km to ground impact for a time interval of 2 hours and 37 minutes. The Probe and the GCMS survived the ground impact and collected data for 1 hour and 9 minutes on the surface in the near surface environment until signal loss by the orbiter. The instrument collected 5634 mass spectra during descent and 2692 spectra on the ground over a range of m/z from 2 to 141. Eight gas chromatograph samples were taken during the descent and two on the ground. This is a report on work in progress. The major constituents of the lower atmosphere were found to be N2 and CH4. The methane-mixing ratio was found to increase below the turbopause, about 35 km altitude, monotonically toward the surface to levels near saturation. After surface impact a steep increase of the mixing ratio was observed suggesting evaporation of surface condensed methane due to heating by the GCMS sample inlet heater. Other constituents were found to be in very low concentrations, below ppm levels. The presence of Argon 40 was confirmed. The results for the other noble gases are still being evaluated. Other hydrocarbons and nitriles were also observed and quantitative evaluation is in progress. Preliminary ratios for the major carbon and nitrogen isotopes were computed from methane and molecular nitrogen measurements.

Niemann, H.↗

First Results From the Gas Chromatograph Mass Spectrometer (GCMS) Experiment on the Cassini-Huygens Probe

The Huygens Probe of the Cassini Huygens Mission entered the atmosphere of the moon Titan on January 14,2005. The GCMS was part of the instrument complement on the Probe to measure in situ the chemical composition of the atmosphere during the probe descent and to support the Aerosol Collector Pyrolyser (ACP) experiment by serving as detector for the pyrolization products. The GCMS employed a quadrupole mass filter with a secondary electron multiplier detection system and a gas sampling system providing continuous direct atmospheric composition measurements and batch sampling through three gas chromatographic (GC) columns. The mass spectrometer employed five electron impact ion sources with available electron energies of either 70 or 25 eV. Three ion sources served as detectors for the GC columns and two were dedicated to direct atmosphere sampling and ACP gas sampling, respectively. The GCMS gas inlet was heated to prevent condensation, and served to evaporate surface constituents after impact.

Niemann, Hasso B.↗

Analysis of Organic Compounds in Mars Analog Samples

The detailed characterization of organic compounds that might be preserved in rocks, ices, or sedimentary layers on Mars would be a significant step toward resolving the question of the habitability and potential for life on that planet. The fact that the Viking gas chromatograph mass spectrometer (GCMS) did not detect organic compounds should not discourage further investigations since (a) an oxidizing environment in the near surface fines analyzed by Viking is likely to have destroyed many reduced carbon species; (b) there are classes of refractory or partially oxidized species such as carboxylic acids that would not have been detected by the Viking GCMS; and (c) the Viking landing sites are not representative of Mars overall. These factors motivate the development of advanced in situ analytical protocols to carry out a comprehensive survey of organic compounds in martian regolith, ices, and rocks. We combine pyrolysis GCMS for analysis of volatile species, chemical derivatization for transformation of less volatile organics, and laser desorption mass spectrometry (LDMS) for analysis of elements and more refractory, higher-mass organics. To evaluate this approach and enable a comparison with other measurement techniques we analyze organics in Mars simulant samples.

Mahaffy, P. R.↗

Analytical Protocols for Analysis of Organic Molecules in Mars Analog Materials

A range of analytical techniques and protocols that might be applied b in situ investigations of martian fines, ices, and rock samples are evaluated by analysis of organic molecules m Mars analogues. These simulants 6om terrestrial (i.e. tephra from Hawaii) or extraterrestrial (meteoritic) samples are examined by pyrolysis gas chromatograph mass spectrometry (GCMS), organic extraction followed by chemical derivatization GCMS, and laser desorption mass spectrometry (LDMS). The combination of techniques imparts analysis breadth since each technique provides a unique analysis capability for Certain classes of organic molecules.

Mahaffy, Paul R.↗