Search NASA⌕ Search

Engineering topics

Demko, J. A.

Publications and source records attributed to Demko, J. A..

Conceptual Design and Performance Considerations for Superconducting Magnets in the Material Plasma Exposure eXperiment

An important step toward the advent of nuclear fusion as a future power source is the development of plasmafacing materials that can function as designed for a long period of time. While ITER and other devices including Wendelstein 7-X and the Joint European Torus will provide insight into divertor and first wall performance, a dedicated device to advance the understanding of material performance in the representative plasma environments is needed. The Material Plasma Exposure eXperiment has been proposed as a linear plasma device to generate and to direct fusion reactor-like plasma energy and particle flux at the target materials with electron temperatures of 1-15 eV and electron densities of 10 20 -10 21 m -3 . Given that the requirements for radio frequency (RF) heating on-axis field are no greater than 2.5 T and the warm bore diameters must be between 60 cm and 1.5 m, the conceptual design was developed for the experiments on a set of superconducting magnets carried out using commercially available NbTi superconductors. This conceptual design evaluated the cryogenic heat loads, mechanical loads, and quench protection to ensure that the current design is compatible with current technologies. In addition, an alternative evaluation of this design relative to ReBCO high-temperature superconducting magnets determined the conditions under which these technologies could be advantageous.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Thermal Performance Testing of Order Dependancy of Aerogels Multilayered Insulation

Robust multilayer insulation systems have long been a goal of many research projects. Such insulation systems must provide some degree of structural support and also mechanical integrity during loss of vacuum scenarios while continuing to provide insulative value to the vessel. Aerogel composite blankets can be the best insulation materials in ambient pressure environments; in high vacuum, the thermal performance of aerogel improves by about one order of magnitude. Standard multilayer insulation (MU) is typically 50% worse at ambient pressure and at soft vacuum, but as much as two or three orders of magnitude better at high vacuum. Different combinations of aerogel and multilayer insulation systems have been tested at Cryogenics Test Laboratory of NASA Kennedy Space Center. Analysis performed at Oak Ridge National Laboratory showed an importance to the relative location of the MU and aerogel blankets. Apparent thermal conductivity testing under cryogenic-vacuum conditions was performed to verify the analytical conclusion. Tests results are shown to be in agreement with the analysis which indicated that the best performance is obtained with aerogel layers located in the middle of the blanket insulation system.

Johnson, Wesley L.↗

Thermal Insulation Performance of Flexible Piping for Use in HTS Power Cables

High-temperature superconducting (HTS) cables that typically operate at temperatures below 80 K are being developed for power transmission. The practical application of HTS power cables will require the use of flexible piping to contain the cable and the liquid nitrogen coolant. A study of thermal performance of multilayer insulation (MLI) was conducted in geometries representing both rigid and flexible piping. This experimental study performed at the Cryogenics Test Laboratory of NASA Kennedy Space Center provides a framework for the development of cost-effective, efficient thermal insulation systems that will support these long-distance flexible lines containing HTS power cables. The overall thermal performance of the insulation system for a rigid configuration and for a flexible configuration, simulating a flexible HTS power cable, was determined by the steady-state liquid nitrogen boiloff method under the full range of vacuum levels. Two different cylindrically rolled material systems were tested: a standard MLI and a layered composite insulation (LCI). Comparisons of ideal MLI, MLI on rigid piping, and MLI between flexible piping are presented.

Fesmire, James E.↗

Overall Thermal Performance of Flexible Piping Under Simulated Bending Conditions

Flexible, vacuum-insulated transfer lines for low-temperature applications have higher thermal losses than comparable rigid lines. Typical flexible piping construction uses corrugated tubes, inner and outer, with a multilayer insulation (MLI) system in the annular space. Experiments on vacuum insulation systems in a flexible geometry were conducted at the Cryogenics Test Laboratory of NASA Kennedy Space Center. The effects of bending were simulated by causing the inner tube to be eccentric with the outer tube. The effects of spacers were simulated in a controlled way by inserting spacer tubes for the length of the cylindrical test articles. Two material systems, standard MLI and a layered composite insulation (LCI), were tested under the full range of vacuum levels using a liquid nitrogen boiloff calorimeter to determine the apparent thermal conductivity (k-value). The results indicate that the flexible piping under simulated bending conditions significantly degrades the thermal performance of the insulation system. These data are compared to standard MLI for both straight and flexible piping configurations. The definition of an overall k-value for actual field installations (k(sub oafi)) is described for use in design and analysis of cryogenic piping systems.

Fesmire, James E.↗

Effect of shaft rotation on the incompressible flow in a labyrinth seal

The incompressible flow in a labyrinth seal at low leakage rates was computationally and experimentally investigated over a wide range of seal rotation rates. QUICK differencing was employed in the finite difference code to reduce the effects of false diffusion. The use of measured inlet boundary conditions for the axial and swirl velocity components and for the turbulent kinetic energy resulted in good agreement between velocity predictions and hot-film measurements. It was found that when the rotation rate is increased beyond a certain point, a second recirculation zone forms inside the seal cavity, altering the flow field in the cavity and resulting in a substantial increase in the pressure drop across it.

Demko, J. A.↗