Search NASA⌕ Search

Engineering topics

Den Hartog, D. J.

Publications and source records attributed to Den Hartog, D. J..

At least 19 records

Overview of Large Helical Device experiments of basic plasma physics for solving crucial issues in reaching burning plasma conditions

Recently, experiments on basic plasma physics issues for solving future problems in fusion energy have been performed on a Large Helical Device. There are several problems to be solved in future devices for fusion energy. Emerging issues in burning plasma are: alpha-channeling (ion heating by alpha particles), turbulence and transport in electron dominant heating helium ash exhaust, reduction of the divertor heat load. To solve these problems, understanding the basic plasma physics of (1) wave–particle interaction through (inverse) Landau damping, (2) characteristics of electron-scale (high-k) turbulence, (3) ion mixing and the isotope effect, and (4) turbulence spreading and detachment, is necessary. This overview discusses the experimental studies on these issues and turbulent transport in multi-ion plasma and other issues in the appendix.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Tokamak Plasmas with Density up to 10 Times the Greenwald Limit

Current-carrying, toroidal laboratory plasmas typically cannot be sustained with an electron density above the empirical Greenwald limit. Presented here are tokamak experiments in the Madison Symmetric Torus with a density up to an unprecedented level about ten times this limit. This is thought to be made possible in part by a thick, stabilizing, conductive wall, and a high-voltage, feedback-controlled power supply driving the plasma current. The radial profile of the toroidal current flattens around twice the limit, without the edge collapse routinely observed in other experiments.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

The Compelling Need for a Mid-Scale Stellarator Facility

In the pursuit of the goal of commercial fusion as an abundant and safe source of energy, the stellarator is a leading concept with compelling attractiveness and demonstrated performance. In this white paper we, as a community of US researchers from Universities, National Laboratories, and Private Industry, involved in studying the stellarator concept, lay out the programmatic and technical motivation for a new mid-size stellarator research facility in the US. This contribution is complementary to several other whitepapers authored by members of our community which address different mid-scale stellarator aspects. A community based technical facility proposal has been prepared by F. Parra, et al: Flexible Stellarator Physics Facility. Two private stellarator companies have submitted proposals supporting the development of a mid-scale stellarator: Thea Energy (C.P.S. Swanson, et al.), Type One Energy (W. Guttenfelder, et al.).

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

The Compelling Need for a Mid-Scale Stellarator Facility

In the pursuit of the goal of commercial fusion as an abundant and safe source of energy, the stellarator is a leading concept with compelling attractiveness and demonstrated performance. A new mid-size stellarator is needed to retire risks and innovate towards a high performance, economically attractive, stellarator Fusion Pilot Plant. In this presentation we, as a community of US researchers from Universities, National Laboratories, and Private Industry, involved in studying the stellarator concept, lay out the programmatic and technical motivation for a new and modern mid-size stellarator research facility. A new mid-scale stellarator is needed to realize the potential predicted by a solid body of theory and simulation along with advances in computational tools for optimization and non-linear turbulence modeling. Notably, it is possible to combine the advantages of the stellarator (steady state, no current drive, no disruptions) with the good confinement regularly achieved in tokamaks. The top priorities for experimental work, and the motivation for a mid-scale stellarator experiment are: turbulence control, non-resonant divertor, MHD stability at large beta, confinement of fast particles, and coil simplification. A new mid-size quasi-symmetric stellarator, built as a user facility, would complement existing research at Wendelstein 7-X and LHD and strongly augment private industry. It would provide a program of innovative research, concept validation, theoretical advancement, and workforce development. Growing support and interest for stellarators by the fusion community and private industry affirms this rationale.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Self-organized magnetic equilibria in tokamak plasmas with very low edge safety factor

Tokamak plasmas often exhibit self-organizing behavior in which internal modes shape the toroidal current density profile, a common example being the sawtooth instability. However, such behavior has not been studied in detail for edge safety factor below 2 due to disruptive kink instabilities that typically prevent operation in this regime. Now, steady tokamak plasmas with an edge safety factor down to 0.8 have been created in the Madison Symmetric Torus, where disruptions are prevented due to a thick, conductive wall and a feedback power supply that sustains the plasma current. Internal measurements and nonlinear magnetohydrodynamic modeling reveal a family of safety factor profiles with a central value clamped near unity as the edge safety factor decreases, indicating current profile broadening through a relaxation process. Furthermore, as the safety factor decreases, the magnetic fluctuations become irregular, and the electron energy confinement time decreases.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Multi-energy reconstructions, central electron temperature measurements, and early detection of the birth and growth of runaway electrons using a versatile soft x-ray pinhole camera at MST

A multi-energy soft x-ray pinhole camera has been designed, built, and deployed at the Madison Symmetric Torus to aid the study of particle and thermal transport, as well as MHD stability physics. This novel imaging diagnostic technique employs a pixelated x-ray detector in which the lower energy threshold for photon detection can be adjusted independently on each pixel. The detector of choice is a PILATUS3 100 K with a 450 μm thick silicon sensor and nearly 100 000 pixels sensitive to photon energies between 1.6 and 30 keV. An ensemble of cubic spline smoothing functions has been applied to the line-integrated data for each time-frame and energy-range, obtaining a reduced standard-deviation when compared to that dominated by photon-noise. The multi-energy local emissivity profiles are obtained from a 1D matrix-based Abel-inversion procedure. Central values of Te can be obtained by modeling the slope of the continuum radiation from ratios of the inverted radial emissivity profiles over multiple energy ranges with no a priori assumptions of plasma profiles, magnetic field reconstruction constraints, high-density limitations, or need of shot-to-shot reproducibility. In tokamak plasmas, a novel application has recently been tested for early detection, 1D imaging, and study of the birth, exponential growth, and saturation of runaway electrons at energies comparable to 100 × Te,0; thus, early results are also presented.

Delgado-Aparicio, L. F. (ORCID:0000000167394380)↗

Microcalorimeter measurement of x-ray spectra from a high-temperature magnetically confined plasma

A NASA-built x-ray microcalorimeter spectrometer has been installed on the MST facility at the Wisconsin Plasma Physics Laboratory and has recorded x-ray photons emitted by impurity ions of aluminum in a majority deuterium plasma. Much of the x-ray microcalorimeter development has been driven by the needs of astrophysics missions, where imaging arrays with few-eV spectral resolution are required. The goal of our project is to adapt these single-photon-counting microcalorimeters for magnetic fusion energy research and demonstrate the value of such measurements for fusion science. Microcalorimeter spectrometers combine the best characteristics of the x-ray instrumentation currently available on fusion devices: high spectral resolution similar to an x-ray crystal spectrometer and the broadband coverage of an x-ray pulse height analysis system. Fusion experiments are increasingly employing high-Z plasma-facing components and require measurement of the concentration of all impurity ion species in the plasma. This diagnostic has the capability to satisfy this need for multi-species impurity ion data and will also contribute to measurements of impurity ion temperature and flow velocity, Zeff, and electron density. Here, we introduce x-ray microcalorimeter detectors and discuss the diagnostic capability for magnetic fusion energy experiments. We describe our experimental setup and spectrometer operation approach at MST, and we present the results from an initial measurement campaign.

Eckart, M. E. (ORCID:0000000338945889)↗

Robust analysis of space-, time-, and energy-resolved soft x-ray measurements of magnetically confined fusion plasmas (invited)

A novel compact multi-energy soft x-ray (ME-SXR) diagnostic based on the PILATUS3 100K x-ray detector has been developed in collaboration between the Princeton Plasma Physics Laboratory and the University of Wisconsin-Madison and tested on the Madison Symmetric Torus (MST) reversed-field pinch. This solid-state photon-counting detector consists of a two-dimensional array of ~100 000 pixels for which the lower photon absorption cutoff energy can be independently set, allowing it to be configured for a unique combination of simultaneous spatial, spectral, and temporal resolution of ~1 cm, 100 eV, and 500 Hz, respectively. The diagnostic is highly versatile and can be readily adapted to diverse plasma operating conditions and scientific needs without any required downtime. New results from improved-confinement and quasi-single helicity plasmas in the MST demonstrate how the detector can be applied to study multiple aspects of the evolution of magnetically confined fusion-grade plasmas. These include observing the evolution of thermal emissivity, characterizing the energy of mid-Z excitation lines, extracting the T e profile, and observing the evolution of non-thermal populations. A technique for integrating the ME-SXR diagnostic into an integrated data analysis framework based on Bayesian inference is also presented. As a result, this allows ME-SXR measurements to be combined with data for complementary diagnostics in order to simultaneously infer Te and nZ from all available information.

47 OTHER INSTRUMENTATION↗

Intrinsic flow and tearing mode rotation in the RFP during improved confinement

We use charge exchange recombination spectroscopy to make the first localized measurements of impurity ion flow velocity profiles in the reversed field pinch. Measurements in improved confinement plasmas reveal an intrinsic flow profile that is peaked on axis and mostly parallel to the equilibrium magnetic field. The toroidal flow decreases in time at off-axis locations where tearing modes are resonant, giving rise to a highly sheared flow profile near the axis. The tearing mode phase velocity correlates strongly with toroidal flow near the resonant surface and weakly with flow in other locations, providing an opportunity to verify the commonly held assumption that the plasma and mode move together at the resonant surface. Mechanisms for the observed momentum loss during the improved confinement period are evaluated and it is found that eddy currents in the conducting shell caused by the rotation of the dominant tearing mode dominate over other losses.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Measurements of Impurity Transport Due to Drift-Wave Turbulence in a Toroidal Plasma

The first direct measurements of an impurity particle flux driven by drift-wave turbulence in a toroidal magnetized plasma are reported. The correlation between the impurity density and radial velocity fluctuations is measured using ion Doppler spectroscopy. The small, very fast radial velocity fluctuation is resolved with the aid of a new linearized spectrum correlation analysis method that rejects uncorrelated noise as the sample size increases. The measured C 2+ turbulent impurity flux in the edge of the plasma is directed inward and is consistent with impurity density measurements. This is also the first direct evidence for fluctuation-induced transport due to trapped-electron-mode turbulence in reversed field pinch plasmas.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Using integrated data analysis to extend measurement capability (invited)

The analysis approach called integrated data analysis (IDA) provides a means to exploit all information present in multiple streams of raw data to produce the best inference of a plasma parameter. This contrasts with the typical approach in which information (data) from a single diagnostic is used to measure a given parameter, e.g., visible bremsstrahlung → Z eff . Data from a given diagnostic usually contain information on many parameters. For example, a Thomson scattering diagnostic is sensitive to bremsstrahlung and line emission in addition to electron temperature. This background light is typically subtracted off and discarded but could be used to improve knowledge of Z eff . IDA encourages explicit awareness of such information and provides the quantitative framework to exploit it. This gives IDA the ability to increase spatial and temporal resolution, increase precision and accuracy of inferences, and measure plasma parameters that are difficult or impossible to measure using single diagnostic techniques. One example is the measurement of Z eff on Madison symmetric torus using IDA since no single diagnostic can provide a robust measurement. Thus, as we enter the burning plasma era, application of IDA will be critical to the measurement of certain parameters, as diagnostic access in the harsh fusion environment will be extremely limited.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Electron thermal confinement in a partially stochastic magnetic structure

Using a high-repetition-rate Thomson scattering diagnostic, we observe a peak in electron temperature $T_e$ coinciding with the location of a large magnetic island in the Madison Symmetric Torus. Magnetohydrodynamic modeling of this quasi-single helicity plasma indicates that smaller adjacent islands overlap with and destroy the large island flux surfaces. The estimated stochastic electron thermal conductivity (≈30 m 2 /s) is consistent with the conductivity inferred from the observed $T_e$ gradient and ohmic heating power. Island-shaped $T_e$ peaks can result from partially stochastic magnetic islands.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Incorporating Beam Attenuation Calculations into an Integrated Data Analysis Model for Ion Effective Charge

Here, we have created a forward model for charge-exchange impurity density measurements that incorporates neutral beam attenuation measurements self-consistently for the purpose of determining the ion-effective charge Z eff . The model is constructed within an integrated data analysis framework to include a self-consistent calculation of neutral beam attenuation due to multiple impurity species into the measurement of a single impurity density. The model includes measurements of the beam Doppler-shift spectrum and shine-through particle flux to determine the neutral beam particle density which is attenuated by ion collisions. Synthetic data are generated from the diagnostic forward model using statistical and calibration uncertainties. These “noisy” data are used in the analysis to evaluate how accurately Z eff is determined. Methods of experimental design are employed to calculate the information gained from different diagnostic combinations. The analysis shows that while attenuation measurements alone do not provide a unique impurity density measurement in the case of a multispecies inhomogeneous plasma, they do provide an effective measurement of the Z eff profile and place constraints on the impurity density profiles.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Linearized spectrum correlation analysis for line emission measurements

A new spectral analysis method, Linearized Spectrum Correlation Analysis (LSCA), for charge exchange and passive ion Doppler spectroscopy is introduced to provide a means of measuring fast spectral line shape changes associated with ion-scale micro-instabilities. This analysis method is designed to resolve the fluctuations in the emission line shape from a stationary ion-scale wave. The method linearizes the fluctuations around a time-averaged line shape (e.g., Gaussian) and subdivides the spectral output channels into two sets to reduce contributions from uncorrelated fluctuations without averaging over the fast time dynamics. In principle, small fluctuations in the parameters used for a line shape model can be measured by evaluating the cross spectrum between different channel groupings to isolate a particular fluctuating quantity. High-frequency ion velocity measurements (100–200 kHz) were made by using this method. We also conducted simulations to compare LSCA with a moment analysis technique under a low photon count condition. Both experimental and synthetic measurements demonstrate the effectiveness of LSCA.

47 OTHER INSTRUMENTATION↗

Magnetic and velocity fluctuations from nonlinearly coupled tearing modes in the reversed field pinch with and without the reversal surface

Here, we investigate the role of poloidal mode number m = 0 fluctuations on m = 1 velocity and magnetic field fluctuations in the Reversed Field Pinch (RFP). Removing the m = 0 resonant surface in the Madison Symmetric Torus (MST), results in suppressed m = 0 activity without a reduction in m = 1 magnetic activity. However, the m = 1 velocity fluctuations and fluctuation-induced mean emf are reduced as m = 0 modes are suppressed. Velocity fluctuations are measured directly using fast Doppler spectroscopy. Similar results are seen in visco-resistive MHD simulation with the DEBS code. An artificial line-averaged velocity diagnostic is developed for DEBS simulations to facilitate direct comparisons with experimental measurements. The sensitivity of the m = 1 velocity fluctuations and corresponding emf to changes in m = 0 mode activity is a feature of tearing modes in the nonlinear regime with a spectrum of interacting modes. These results have implications for RFP sustainment strategies and inform our understanding of the role of magnetic turbulence in astrophysical contexts

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Identification and mitigation of stray laser light in the Thomson scattering system on the Madison Symmetric Torus (MST)

The Thomson scattering diagnostic on the Madison Symmetric Torus (MST) records excessive levels of stray Nd:YAG laser light. Stray light saturates the 1064 nm spectral channel in all polychromators, which prevents absolute electron density measurements via Rayleigh scattering calibration. Furthermore, stray light contaminates adjacent spectral channels for r/a ≥ 0.75, which renders the diagnostic unable to make electron temperature measurements at these radii. In situ measurements of stray light levels during a vacuum vessel vent are used to identify stray light sources and strategies for reduction of stray light levels. Numerical modeling using Zemax OpticStudio supports these measurements. The model of the vacuum vessel and diagnostic includes synthetic collection optics to enable direct comparison of measured and simulated stray light levels. Modeling produces qualitatively similar stray light distributions to MST measurements, and quantifies the mitigation effects of stray light mitigation strategies prior to implementation.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗