Publications and source records attributed to Denton, M Bonner.

Evaluation of a fourth-generation focal plane camera for use in plasma-source mass spectrometry

A fourth-generation focal plane camera containing 1696 Faraday-strip detectors was fitted to a Mattauch-Herzog mass spectrograph and characterized for its performance with inductively coupled plasma ionization. The camera provides limits of detection in the single to tens of ng L-1 range for most elements and has a linear dynamic range of at least nine orders of magnitude. Isotope-ratio precision better than 0.02% has also been achieved with this device, and this fourth-generation system features the broadest simultaneous mass range obtainable to date with this family of focal plane camera detectors.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Method and apparatus for simultaneous detection and measurement of charged particles at one or more levels of particle flux for analysis of same

A charged particle detector and method are disclosed providing for simultaneous detection and measurement of charged particles at one or more levels of particle flux in a measurement cycle. The detector provides multiple and independently selectable levels of integration and/or gain in a fully addressable readout manner.

47 OTHER INSTRUMENTATION↗

Use of an ambient ionization flowing atmospheric-pressure afterglow source for elemental analysis through hydride generation

An ambient mass spectrometry ionization source based on an atmospheric-pressure flowing afterglow has been coupled to a Mattauch-Herzog mass spectrograph capable of simultaneous acquisition of a range of mass-to-charge values by means of a Faraday-strip array detector. The flowing afterglow was used as the ionization pathway for species produced by hydride generation. This ionization strategy circumvents problems, such as discharge instabilities or memory effects, induced by introducing the gaseous sample into the discharge. The generated spectra show both atomic and molecular peaks; calibration curves were calculated for both peak types with limits of detection for arsenic below 10 ppb. This study demonstrates the ability to use an ambient mass spectrometry source, commonly used for molecular analyses, for the detection of gas phase elemental species with the possibilty of performing speciation by coupling with a separation technique.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Continuous Simultaneous Detection in Mass Spectrometry

In mass spectrometry, several advantages can be derived when multiple mass-to-charge values are detected simultaneously. One such advantage is an improved duty cycle, which leads to superior limits of detection, better precision, shorter analysis times, and reduced sample sizes. A second advantage is the ability to reduce correlated noise by taking the ratio of two or more simultaneously collected signals, enabling greatly enhanced isotope ratio data. A final advantage is the elimination of spectral skew, leading to more accurate transient signal analysis. Here, these advantages are demonstrated by means of a novel Faraday-strip array detector coupled to a Mattauch-Herzog mass spectrograph. The same system is used to monitor elemental fractionation phenomena in laser ablation inductively coupled plasma mass spectrometry.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗