Search NASA⌕ Search

Engineering topics

Deo, N

Publications and source records attributed to Deo, N.

Gamma discrimination in pillar structured thermal neutron detectors

Solid-state thermal neutron detectors are desired to replace {sup 3}He tube based technology for the detection of special nuclear materials. {sup 3}He tubes have some issues with stability, sensitivity to microphonics and very recently, a shortage of {sup 3}He. There are numerous solid-state approaches being investigated that utilize various architectures and material combinations. By using the combination of high-aspect-ratio silicon PIN pillars, which are 2 {micro}m wide with a 2 {micro}m separation, arranged in a square matrix, and surrounded by {sup 10}B, the neutron converter material, a high efficiency thermal neutron detector is possible. Besides intrinsic neutron detection efficiency, neutron to gamma discrimination is an important figure of merit for unambiguous signal identification. In this work, theoretical calculations and experimental measurements are conducted to determine the effect of structure design of pillar structured thermal neutron detectors including: intrinsic layer thickness, pillar height, substrate doping and incident gamma energy on neutron to gamma discrimination.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

RNA matrix models with external interactions and their asymptotic behavior

We study a matrix model of RNA in which an external perturbation on n nucleotides is introduced in the action of the partition function of the polymer chain. The effect of the perturbation appears in the exponential generating function of the partition function as a factor exp(1-n{alpha}/L) (where {alpha} is the ratio of strengths of the original to the perturbed term and L is the length of the chain). The asymptotic behavior of the genus distribution functions as a function of length for the matrix model with interaction is analyzed numerically for all n{<=}L. It is found that as n{alpha}/L is increased from 0 to 1, the term 3{sup L} in the number of diagrams a{sub L,g,{alpha}}{sup '} at a fixed length L, genus g and {alpha}, goes to 2{sup L}[(3-(n{alpha}/L)){sup L} for any n{alpha}/L] and the total number of diagrams N{sub {alpha}}{sup '} at a fixed length L and {alpha} but independent of genus g, undergoes a change in the factor exp({radical}(L)) to 1 (exp[(1-n{alpha}/L){radical}(L)] for any n{alpha}/L). However the exponent L of the dominant length dependent term in a{sub L,g,{alpha}}{sup '} stays unchanged. Hence the universality is robust to changes in the interaction ({alpha}). The distribution functions also exhibit unusual behavior at small lengths.

60 APPLIED LIFE SCIENCES↗

Planarization of High Aspect Ratio P-I-N Diode Pillar Arrays for Blanket Electrical Contacts

Two planarization techniques for high aspect ratio three dimensional pillar structured P-I-N diodes have been developed in order to enable a continuous coating of metal on the top of the structures. The first technique allows for coating of structures with topography through the use of a planarizing photoresist followed by RIE etch back to expose the tops of the pillar structure. The second technique also utilizes photoresist, but instead allows for planarization of a structure in which the pillars are filled and coated with a conformal coating by matching the etch rate of the photoresist to the underlying layers. These techniques enable deposition using either sputtering or electron beam evaporation of metal films to allow for electrical contact to the tops of the underlying pillar structure. These processes have potential applications for many devices comprised of 3-D high aspect ratio structures. Two separate processes have been developed in order to ensure a uniform surface for deposition of an electrode on the {sup 10}Boron filled P-I-N pillar structured diodes. Each uses S1518 photoresist in order to achieve a relatively uniform surface despite the non-uniformity of the underlying detector. Both processes allow for metallization of the final structure and provide good electrical continuity over a 3D pillar structure.

42 ENGINEERING↗

Comparison of CF4 and SF6 based plasmas for ECR etching of isotopically enriched 10Boron films

Isotopically enriched {sup 10}boron films have been successfully etched in an ECR etching tool using CF{sub 4} and SF{sub 6} based plasmas. Comparisons between the two are made with regards to etch rate, selectivity to the underlying Si device structure, and morphology of the {sup 10}boron post-etching. The present film etching development is expected to be critical for the fabrication of next generation thermal neutron solid state detectors based on {sup 10}boron.

42 ENGINEERING↗

6:1 aspect ratio silicon pillar based thermal neutron detector filled with {sup 10}B

Current helium-3 tube based thermal neutron detectors have shortcomings in achieving simultaneously high efficiency and low voltage while maintaining adequate fieldability performance. By using a three-dimensional silicon p-i-n diode pillar array filled with boron-10 these constraints can be overcome. The fabricated pillar structured detector reported here is composed of 2 {mu}m diameter silicon pillars with a 4 {mu}m pitch and height of 12 {mu}m. A thermal neutron detection efficiency of 7.3+/-0.6% and a neutron-to-gamma discrimination of 10{sup 5} at 2 V reverse bias were measured for this detector. When scaled to larger aspect ratio, a high efficiency device is possible.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Numerical Simulations of Pillar Structured Solid State Thermal Neutron Detector Efficiency and Gamma Discrimination

This work reports numerical simulations of a novel three-dimensionally integrated, {sup 10}boron ({sup 10}B) and silicon p+, intrinsic, n+ (PIN) diode micropillar array for thermal neutron detection. The inter-digitated device structure has a high probability of interaction between the Si PIN pillars and the charged particles (alpha and {sup 7}Li) created from the neutron - {sup 10}B reaction. In this work, the effect of both the 3-D geometry (including pillar diameter, separation and height) and energy loss mechanisms are investigated via simulations to predict the neutron detection efficiency and gamma discrimination of this structure. The simulation results are demonstrated to compare well with the measurement results. This indicates that upon scaling the pillar height, a high efficiency thermal neutron detector is possible.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Pillar Structured Thermal Neutron Detector

This work describes an innovative solid state device structure that leverages advanced semiconductor fabrication technology to produce an efficient device for thermal neutron detection which we have coined the 'Pillar Detector'. State-of-the-art thermal neutron detectors have shortcomings in simultaneously achieving high efficiency, low operating voltage while maintaining adequate fieldability performance. By using a three dimensional silicon PIN diode pillar array filled with isotopic {sup 10}boron ({sup 10}B), a high efficiency device is theoretically possible. Here we review the design considerations for going from a 2-D to 3-D device and discuss the materials trade-offs. The relationship between the geometrical features and efficiency within our 3-D device is investigated by Monte Carlo radiation transport method coupled with finite element drift-diffusion carrier transport simulations. To benchmark our simulations and validate the predicted efficiency scaling, experimental results of a prototype device are illustrated. The fabricated pillar structures reported in this work are composed of 2 {micro}m diameter silicon pillars with a 2 {micro}m spacing and pillar height of 12 {micro}m. The pillar detector with a 12 {micro}m height achieved a thermal neutron detection efficiency of 7.3% at a reverse bias of -2 V.

36 MATERIALS SCIENCE↗

Fabrication of Pillar-Structured Thermal Neutron Detectors

Pillar detector is an innovative solid state device structure that leverages advanced semiconductor fabrication technology to produce a device for thermal neutron detection. State-of-the-art thermal neutron detectors have shortcomings in achieving simultaneously high efficiency, low operating voltage while maintaining adequate fieldability performance. By using a 3-dimensional silicon PIN diode pillar array filled with isotopic boron 10, ({sup 10}B) a high efficiency device is theoretically possible. The fabricated pillar structures reported in this work are composed of 2 {micro}m diameter silicon pillars with a 4 {micro}m pitch and pillar heights of 6 and 12 {micro}m. The pillar detector with a 12 {micro}m height achieved a thermal neutron detection efficiency of 7.3% at 2V.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗