Search NASA⌕ Search

Engineering topics

Desjarlais, André Omer

Publications and source records attributed to Desjarlais, André Omer.

Natural fibers as promising core materials of vacuum insulation panels

To reduce energy consumption in buildings, this paper investigates the feasibility of using natural fibers as cost-effective, environmentally sustainable core materials for vacuum insulation panels (VIPs). First, a comprehensive experimental study was conducted for 10 potential natural fiber candidates. The thermal conductivities of the 10 natural fiber mats at various vacuum pressures were measured; their compression and morphology properties were quantified. In addition, an analytical model was used to explore the major factors that influence the thermal conductivity of natural fibers as a function of internal air pressure. Results show that recycled cotton, kapok, and bamboo fibers are ideal candidates for VIP core materials; at <0.05 Pa, their thermal conductivities varied between 2 and 4 mW/(m∙K). Furthermore, for some fibers, thermal conductivity was inversely proportional to fiber density. For the selection of fiber materials for VIP cores, the ideal fiber candidate has a small fiber diameter and a low fiber mat density. Based on thermal measurements, even though the internal air pressure of 5 Pa was enough to attain the minimum thermal conductivity, obtaining internal air pressure below 5 Pa is recommended for prolonged service life, considering small leaks of VIP package barrier films and potential off-gassing from fibers. The simulation results predicting the effective thermal conductivities matched the experimental results well. These findings indicate that natural fiber–based VIPs have the potential to be a sustainable, inexpensive alternative to the current technologies in building insulation materials.

36 MATERIALS SCIENCE↗

Impact of Insulation Strategies of Cross-Laminated Timber Assemblies on Energy Use, Peak Demand, and Carbon Emissions

Cross-Laminated Timber (CLT) panels have many structural benefits but do not have much thermal resistance. We have developed a solution to insulate CLT structures that uses high-performance insulation panels that provide R-values up to R40/inch. The CLT panels are made of layers of wood laminates (three, five, seven or more). The solution replaces some of the wood laminates in the CLT production with the insulation panels in a staggered fashion so that the wood laminates maintain contact throughout the panel, ensuring the CLT panel’s structural integrity. The insulated CLT panels have factory-installed water-resistive barriers reducing the installation time by eliminating installing insulation and water-resistive barriers on site. Per simulations, the CLT/insulation panel achieved code-required insulation levels with commonly available insulation materials. The significance of the thermal mass of CLT/insulation hybrid building envelopes was quantified by comparing the whole building energy performance and peak demand of traditional low mass and CLT wall assemblies resulting in up to 7% reduction in peak demand for cooling in Knoxville, TN, in a multifamily building. Buildings contribute over 40 percent of carbon emissions. The proposed CLT/insulation hybrid building envelope addresses both operational and embodied carbon by having high thermal resistances due to the embedded insulation sections and eliminating the use of high embodied carbon materials such as steel and concrete. The carbon benefit is estimated.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Assessing Methodologies for Detecting Water Intrusion in Wall Systems: Phase 2

Studies by the University of Florida, the Environmental Protection Agency (EPA) and the U.S. Department of Housing (HUD) have revealed that there is a substantial fraction of commercial and residential buildings that have been exposed to moisture resulting in damage or durability problems. Water intrusion into building envelope components leads to a variety of undesirable conditions such as mold, wood rot, corrosion, and aesthetic damage. Tests methods that are presently used to evaluate the amount of water intrusion into a building envelope component are usually qualitative in nature. For example, ASTM E 331, Standard Test Method for Water Penetration of Exterior Windows, Curtain Walls, and Doors by Uniform Static Air Pressure Difference requires that you “observe and record points of water leakage, if any.” This test was originally developed to assess the performance of fenestration products but is commonly adapted to evaluate other enclosure assemblies. However, when it is typically used for walls, this procedure is limited to recognizing if the moisture is visually observable from the backside side of the sheathing. It does not address moisture that is absorbed in the layers of the building envelope component, which could impact the durability of the assembly. Clearly a quantitative means of determining water penetration would improve the quality of this type of test and assist with better understanding the resultant impact on enclosure assemblies. In 2018-20, Oak Ridge National Laboratory, in conjunction with the Air Barrier Association of America, initiated a research project to address this issue. The purpose of that study was to evaluate nine different methods of detecting moisture intrusion through a wall assembly. air and water barrier. The wall assemblies included metal frame construction faced with gypsum sheathing and both self-adhered and fluid applied air and water barriers (AWB) were evaluated for this exercise. This project did not test the efficacy of the different AWBs, rather, fasteners were purposely installed in various ways to foster water penetration and activate the different methods of detection. Each detection method was evaluated for five features that included simplicity of use, cost of implementation, whether the method was quantitative or subjective, accuracy, and applicability. A scale of green/yellow/red was used to assess each feature where green was acceptable, yellow was borderline, and red was not to be pursued at this time. This report covers additional research that has been undertaken to extend the activities initiated in this earlier project with refinements for specific detection methods and considerations for expansion related to field versus laboratory testing standards.

42 ENGINEERING↗

An All-Ceramic, Anisotropic, and Flexible Aerogel Insulation Material

To exploit the high-temperature superinsulation potential of anisotropic thermal management materials, the incorporation of ceramic aerogel into the aligned structural networks is indispensable. Yet, the long-standing obstacle to exploring ultralight superinsulation ceramic aerogels is the inaccessibility of its mechanical elasticity, stability, and anisotropic thermal insulation. Here, we report a recoverable, flexible ceramic fiber-aerogel composite with anisotropic lamellar structure, where the interfacial cross-linking between ceramic fiber and aerogel is important in its superinsulation performance. The resulting ultralight aerogel composite exhibits a density of 0.05 g/cm 3 , large strain recovery (over 50%), and low thermal conductivity (0.0224 W m –1 K –1 ), while its hydrophobicity is achieved by in situ trichlorosilane coating with the water contact angle of 135°. The hygroscopic tests of such aerogel composites demonstrate a reversible thermal insulation. The mechanical elasticity and stability of the anisotropic composites, with its soundproof performance, shed light on the low-cost superelastic aerogel manufacturing with scalability for energy saving building applications.

36 MATERIALS SCIENCE↗