Search NASA⌕ Search

Engineering topics

Desteese, J. G.

Publications and source records attributed to Desteese, J. G..

Electrodes for the thermionic converters, phase 2 - 3

The characteristics of electrodes for thermionic converters are discussed. A metal/ceramic Marchuk tube was constructed and operated with a quiescent cesium vapor plasma corresponding to cesium liquid reservoir temperatures from 376 to 427 K. The work function characteristics of tantalum test emitters coated with anodic films were measured to evaluate the applicability of the materials as the collector surface in a plasma mode thermionic converter. Work function minimum values between 1.4 and 1.5 electron volts were observed. The effect of the electronegative surface layers was partially obscured by additive vapor impurities detected by the clean tantalum reference emitter.

Desteese, J. G.↗

Feasibility study of oxygen-dispensing emitters for thermionic converters, phase 1

A metal/ceramic Marchuk tube was used to measure work functions of oxygen-doped tantalum, to determine applicability of the material to plasma-mode thermionic converters. Oxygen-doped tantalum was shown to increase in work function monotonically with oxygen doping in the range 0.1 to 0.3 atomic percent. Oxygenated test emitters were run at an average temperature of 2165 K and a T/T sub Cs ratio -5.8 to observe the influence of oxygen depletion. Bare work function decreased with outgassing of oxygen. Projections were made based on outgassing kinetics and area/volume ratios to calculate the longevity of oxygen doping in a practical converter. Calculations indicated that the program goal of 10,000 hr could be achieved at 1800 K with an initial oxygen doping of 1 atomic percent and a practical emitter area/volume ratio.

Desteese, J. G.↗

Detailed design of a 100-We multicell thermionic power supply.

Confirmation of the general trends of a previously reported parametric study of plutonia-fueled thermionic generators in a detailed 100-We generator design. The detailed design takes into account the additional weight of system-integration components and shows that design refinements of all aeroshell components are possible when a specific generator configuration is considered. An optimized 100-We thermionic power supply design is presented, reflecting a 0.98 reliability goal after five years of operation. The optimum multicell array consists of 28 isomite converters, each producing approximately 3.6 We at end-of-life. The optimum arrangement of converters in the aeroshell is a four-column, seven-row stacking configuration connected electrically as a two-column, 14-row array.

Rouklove, P.↗