Search NASA⌕ Search

Engineering topics

Devin, Michael Carl

Publications and source records attributed to Devin, Michael Carl.

Reduced-Order Modeling of Hydrogen Releases from Vent Stacks and with Wind

This report describes computational modeling in the HyRAM+ software for study of hydrogen behavior in two common scenarios. First, models of unignited plumes exiting a vent stack were considered. It was shown that entrainment and vent backpressure were major factors in plume physics. Second, HyRAM+ was extended to include wind effects on plumes by modifying the plume momentum balance and entrainment modeling. Use of the model showed that plume shape and length changed with wind speed and direction; in all cases, wind causes a shortening of the plume along the streamline. While the no-wind case in HyRAM+ has been validated and the newly developed wind model was fitted to very limited experimental data, more controlled experimental configurations would help validate the models and ensure accurate simulation of hydrogen plume behavior for vent stack releases or in wind.

08 HYDROGEN↗

Validation of HyRAM+ Version 5.1 Physics Models

The Hydrogen Plus Other Alternative Fuels Risk Assessment Models (HyRAM+) software has seen various improvements and additional physics capabilities since validation against experimental data was last published for HyRAM v3.1. Notably, HyRAM+ now includes four models allowing for the calculation of overpressure resulting from vapor cloud explosions from unconfined jet releases. As with the previous HyRAM validation report, validation data was gathered from available published literature and tested against HyRAM+ capabilities. The validation comparisons include tank blowdown, unignited dispersion jet plume, ignited jet flame, and enclosed accumulation and overpressure. The unconfined overpressure calculations in HyRAM+ v5.1.1 generally show good agreement with many of the experimental data sets for all four unconfined overpressure models, though HyRAM+ overpredicts the experimental data for small and cryogenic hydrogen releases. The comparisons for the other HyRAM+ physics models are largely unchanged from the previously published validation report.

08 HYDROGEN↗

High-dimensional control co-design of a wave energy converter with a novel pitch resonator power takeoff system

Researchers are exploring adding wave energy converters to existing oceanographic buoys to provide a predictable source of renewable power. A ”pitch resonator” power take-off system has been developed that generates power using a geared flywheel system designed to match resonance with the pitching motion of the buoy. However, the novelty of the concept leaves researchers uncertain about various design aspects of the system. This work presents a novel design study of a pitch resonator to inform design decisions for an upcoming deployment of the system. The assessment uses control co-design via WecOptTool to optimize control trajectories for maximal electrical power production while varying five design parameters of the pitch resonator. Given the large search space of the problem, the control trajectories are optimized within a Monte Carlo analysis to identify optimal designs, followed by parameter sweeps around the optimum to identify trends between the design parameters. The gear ratio between the pitch resonator spring and flywheel are found to be the most sensitive design variables to power performance. Finally, the assessment also finds similar power generation for various sizes of resonator components, suggesting that correctly designing for optimal control trajectories at resonance is more critical to the design than component sizing.

16 TIDAL AND WAVE POWER↗

Co-design of a wave energy converter for autonomous power

A "bolt-on" wave energy converter is designed to provide power for sensors on an existing oceanographic buoy. The narrow-banded pitch/roll response of the target oceanographic buoy lends itself to a tuned-resonator design, for which we suggest a novel "pitch resonator" wave energy converter concept. Using a pseudo-spectral method, the performance of the proposed wave energy converter is modeled in the range of sea states expected to be present at the target deployment location to study the e

Coe, Ryan Geoffrey↗

Anchoring Strategies for Marine Renewable Energy at the Sandia Water Impact Facility

This report documents the formulation and preliminary analysis of potential anchoring strategies for use in future WEC testing at the Sandia Water Impact Facility given the existing 5-ton and 10-ton concrete blocks at the facility. Three anchoring strategies are created that are applicable to different mooring configurations for existing WECs of interest for testing. The three anchoring strategies have a maximum allowable load of between 24.57 kN and 281.17 kN, depending on whether the 5-ton or 10-ton blocks are used, with Strategy 3 with 10-ton blocks having the highest allowable load. The AquaHarmonics and CalWave xWave WECs can be tested up to a 1:1.5 and 1:1.15 scale, respectively, while maintaining a mooring configuration very close to the one used in ocean deployment. The requirements for the mooring lines, shackles, and triplates needed to support the three strategies are also calculated, with commercially available products specified. Finally, the padeyes connected to the existing concrete blocks are assessed and determined to be satisfactory for the loading expected with these anchoring strategies.

16 TIDAL AND WAVE POWER↗

ARCUS Vertical-Axis Wind Turbine (Final Scientific/Technical Report)

While land-based wind energy has become economically competitive with traditional energy generation sources in the U.S., offshore wind is not. For floating offshore wind this difference is even more substantial where the levelized cost of energy (LCOE) is projected to be around 3-5 times more expensive than land-based wind. The turbine capital costs represent around 50% of the LCOE for land-based wind sites, but the increased system costs for floating offshore wind reduce this to 20%. The platform and mooring costs are the single largest contributor to the LCOE for floating offshore wind where their mass must counteract the overturning moment caused by the turbine’s thrust force. Despite the high costs of the platform and relatively low cost of the turbine, current offshore wind turbines are designed essentially the same as for land-based sites. Reducing the LCOE is the greatest challenge to realize the benefits of sustained development of floating offshore wind in the U.S. Reducing the complicated system costs of floating offshore wind will enable the industry to continue to grow and outpace current projections if reduced cost curves can be reached. The ideal wind energy system would remove all mass and cost that is not directly capturing energy from the wind. For floating offshore wind energy systems, this objective is even more significant as increased mass above the water level must be supported by larger and more expensive floating platforms. For this reason, vertical-axis wind turbines (VAWTs) are ideal for floating offshore sites and have several advantages over horizontal-axis wind turbines (HAWTs) at this scale. Large VAWTs offer opportunities for improved energy capture over HAWTs as single units and with reduced wind plant aerodynamic losses through enhanced wake recovery. Additionally, the platform-level placement of the VAWT drivetrain greatly reduces the demands placed on the floating platform and its mass and cost. The ARCUS vertical-axis wind turbine concept (U.S. 11,421,650 B2) is an iteration beyond traditional Darrieus-type VAWTs that replaces the rigid tower with blades that are bent into shape and held in place with tensioned center supports, like a bow. The ARCUS design has been shown to further decrease the VAWT rotor mass properties, with a 50% reduction over traditional Darrieus VAWTs quantified in the ATLANTIS program. The ARCUS VAWT’s efficient use of material for the rotor and turbine support structures combined with its lowered center of gravity enables a tension-leg platform (TLP) with simplified installation procedures. TLPs have been an emerging platform architecture in the Oil and Gas industry and demonstrated to have the lowest hull mass requirements while maintaining stability with minimal roll and pitch deflections in operation. A 22 MW ARCUS turbine has been designed with a three-column TLP that enables quayside integration of the turbine while maintaining system stability during tow-out and installation and having optimal mass and cost properties. A comprehensive analysis shows the optimal ARCUS TLP system design minimizes LCOE through efficient material usage and increased energy capture to yield a competitive LCOE estimate of $\$$55/MWh. A comparison with a reference HAWT, having the same swept area, quantifies the advantages that helped to produce this improved LCOE for the ARCUS concept: (1) 30% reduction in total turbine mass, (2) 70% reduction in turbine center of gravity, and (3) 45% increase in energy production over what is optimal for a HAWT. Intellectual property has been generated through the ATLANTIS program providing opportunities to further reduce the LCOE and improve the performance of the ARCUS turbine and TLP system, expanding the list of innovations to support commercial development of the ARCUS concept.

17 WIND ENERGY↗

Enabling Floating Offshore VAWT Design by Coupling OWENS and OpenFAST

Vertical-axis wind turbines (VAWTs) have a long history, with a wide variety of turbine archetypes that have been designed and tested since the 1970s. While few utility-scale VAWTs currently exist, the placement of the generator near the turbine base could make VAWTs advantageous over tradition horizontal-axis wind turbines for floating offshore wind applications via reduced platform costs and improved scaling potential. However, there are currently few numerical design and analysis tools available for VAWTs. One existing engineering toolset for aero-hydro-servo-elastic simulation of VAWTs is the Offshore Wind ENergy Simulator (OWENS), but its current modeling capability for floating systems is non-standard and not ideal. This article describes how OWENS has been coupled to several OpenFAST modules to update and improve modeling of floating offshore VAWTs and discusses the verification of these new capabilities and features. The results of the coupled OWENS verification test agree well with a parallel OpenFAST simulation, validating the new modeling and simulation capabilities in OWENS for floating VAWT applications. These developments will enable the design and optimization of floating offshore VAWTs in the future.

17 WIND ENERGY↗