Search NASA⌕ Search

Engineering topics

Devlin, Matthew

Publications and source records attributed to Devlin, Matthew.

Templates of expected measurement uncertainties

The covariance committee of CSEWG (Cross Section Evaluation Working Group) established templates of expected measurement uncertainties for neutron-induced total, (n,γ), neutron-induced charged-particle, and (n,xn) reaction cross sections as well as prompt fission neutron spectra, average prompt and total fission neutron multiplicities, and fission yields. Templates provide a list of what uncertainty sources are expected for each measurement type and observable, and suggest typical ranges of these uncertainties and correlations based on a survey of experimental data, associated literature, and feedback from experimenters. Information needed to faithfully include the experimental data in the nuclear-data evaluation process is also provided. These templates could assist (a) experimenters and EXFOR compilers in delivering more complete uncertainties and measurement information relevant for evaluations of new experimental data, and (b) evaluators in achieving a more comprehensive uncertainty quantification for evaluation purposes. This effort might ultimately lead to more realistic evaluated covariances for nuclear-data applications. In this topical issue, we cover the templates coming out of this CSEWG effort–typically, one observable per paper. This paper here prefaces this topical issue by introducing the concept and mathematical framework of templates, discussing potential use cases, and giving an example of how they can be applied (estimating missing experimental uncertainties of 235 U(n,f) average prompt fission neutron multiplicities), and their impact on nuclear-data evaluations.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Templates of expected measurement uncertainties for prompt fission neutron spectra

In this paper, we provide templates of uncertainty sources expected to appear for three measurement types of prompt fission neutron spectra (PFNS): (1) shape measurements, (2) clean-ratio shape, that is the monitor PFNS are measured in nearly exactly the same surrounding as the PFNS of interest, and (3) indirect ratios, where the detector efficiency is backed out from PFNS monitor measurements. Information is also listed that is needed to faithfully include PFNS in nuclear data evaluations to guide experimenters on how to best report data and metadata for their measurements. These templates also suggest a typical range of pertinent uncertainty values and their correlations in case realistic uncertainties cannot be estimated from information on the measurement itself. The templates were based on a literature review, information found in EXFOR for 252 Cf, 235, 238 U, and 239 Pu PFNS, and enhanced by expertise from experimenters contributing to these PFNS templates.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Templates of expected measurement uncertainties for average prompt and total fission neutron multiplicities

In this paper, we provide templates of measurement uncertainty sources expected to appear for average prompt- and total-fission neutron multiplicities, $ \overline\nu_p $ and $ \overline\nu_t $, for the following measurement types: absolute manganese-bath experiments for $ \overline\nu_t $, absolute and ratio liquid-scintillator measurements for $ \overline\nu_p $. These templates also suggest a typical range of these uncertainties and their correlations based on a survey of available experimental data, associated literature, and feedback from experimentalists. In addition, the information needed to faithfully include the associated experimental data into the nuclear-data evaluation process is provided.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

The Covariance of PFNS Results from the Chi-Nu Experiment

The prompt fission neutron spectrum (PFNS) from neutron-induced fission is a fundamental quantity for the behavior of nuclear reactors, and has been measured many times on a wide variety of nuclei and covering different ranges of incident and emitted neutron energies. However, results from past measurements are frequently called into question in modern nuclear data evaluations because of a lack of thorough experimental documentation and incomplete uncertainty analyses. The Chi-Nu experiment at Los Alamos National Laboratory was designed to produce high-precision measurements of the PFNS of major actinides over a wide range of incident and emitted neutron energies, and with the documentation and covariance analysis required to ensure that the results of this experiment maintain their impact long into the future, thereby avoiding this pitfall of past measurements. In this work we describe the Chi-Nu experiment along with summaries of the treatment of and methods developed to address two important components of the analysis of Chi-Nu data: random-coincidence backgrounds and MCNP simulations. Furthermore, we describe the first results for correlations not just between all data points collected on a single target nucleus, but also between all data points from separate Chi-Nu measurements on 235 U and 239 Pu. These correlations are important for accurately calculating ratios of the PFNS from one actinide to another, which are rare and can be informative for nuclear data evaluation efforts.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Quasi-differential neutron induced neutron emissions from 235 U, and 239 Pu

Uncertainty in nuclear reaction cross sections, angular distributions, and other nuclear data directly impact how well simulations of nuclear systems represent physical observations. Here, to determine how well the nuclear data in ENDF/B-VIII.0, JEFF-3.3, and JENDL-4.0 evaluations describe the physical behaviour of 235 U, and 239 Pu when subjected to a neutron flux, the neutron emission spectrum was measured for carbon, 93.0% 235 U, and 93.9% 239 Pu samples, and compared against detailed MCNP6 simulations. The measurements were performed at the Los Alamos Neutron Science Center using a quasi-differential method previously developed at Rensselaer Polytechnic Institute. The measurement spanned 0.82–20 MeV and 30–150 degrees. The measurements show there are a significant number of discrepancies between library predictions of the neutron yield and physical observation. A few of the main discrepancies found are described in this paper. Based on these results a new evaluation utilizing these results for carbon, 235 U, and 239 Pu is recommended.

235U↗

Proceedings of the Workshop for Applied Nuclear Data: WANDA2020

On March 3–5, 2020, in Washington, DC, the Nuclear Data Interagency Working Group (NDIAWG) supported the 3-day Workshop for Applied Nuclear Data (WANDA2020) to facilitate interagency collaboration on nuclear data for applications and to communicate mission-driven nuclear data needs. The goal was to assemble users and producers of nuclear data to provide input to identify nuclear data needs, suggest solutions to address those needs, and prioritize potential solutions. The workshop consisted of talks by agency program managers, a nuclear data pipeline panel, six topic-focused roadmapping discussion sessions and a review of NDIAWG-funded projects. More than 160 attendees represented national laboratories, universities, and headquarters, as well as international organizations and industry. The proceedings presented herein summarize the workshop’s content, highlight important outcomes, and document attendees’ recommendations.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗