Event-by-event Neutron-Gamma Multiplicity Correlations in 242Pu(sf)
Explore the source record for details and available documents.
Engineering topics
Publications and source records attributed to Devlin, Matthew James.
Explore the source record for details and available documents.
γ-ray production is the common item of interest. Inelastic n scattering cross sections are frequently the strongest contributors to γ-production cross sections.
Abstract not provided.
Measurements of physical quantities are often made relative to a reference quantity, simplifying the interpretation of the measurement and its uncertainties. However, if applied without careful considerations, this technique can carry with it a significant and complex systematic error that is usually ignored. For example, measurements of continuous neutron spectra relative to a reference spectrum yield a result that does not properly include the important effects of neutron scattering in the experimental environment. These effects act to distort the measured spectrum shape and create notable errors in spectrum-integrated quantities. While this effect is one of a series of known potential sources of systematic error including, but not limited to target impurities, angular distributions, incident beam flux, and others, the error introduced from differences in environmental scattering effects between the reference and desired spectra are frequently overlooked. In this work, we demonstrate the origin of this error using simulated data corresponding to measurements of the neutron-induced prompt fission neutron spectra of 233 U, 235 U, 238 U, and 239 Pu as well as the spontaneous fission neutron spectrum of 252 Cf. Errors in the spectrum shape can be as high as 10%–15% depending on the combination of incident and outgoing neutron energy. The spectrum integral and average spectrum energy also contain errors that change with incident neutron energy and can be as high as ~2%. Although this study is based on simulated data, we also show a method for proving that this error exists in an experimental data set and we show a correction that can be applied to results of this type to obtain a more accurate result, thereby largely removing systematic errors from environmental scattering effects. The potential for these kinds of errors should be considered in measurements producing continuous neutron spectra.
The National Nuclear Security Administration (NNSA)/DP French Alternative Energies and Atomic Energy Commission (CEA)/DAM agreement on cooperation on fundamental science is a U.S.-French collaborative effort to combine intellectual and experimental resources and further the relevant nuclear science. Recently, both the NNSA and CEA experimental teams performed high-statistics measurements of the 239 Pu(n, f) prompt fission neutron spectrum (PFNS) at the Los Alamos Neutron Science Center, both of which were recently published in the journal Physical Review C. These separate measurements used the same experimental area and a common neutron detector array, but differ in many aspects, including background assessments, data acquisition systems and philosophies, fission detectors, and PFNS extraction techniques. Hence, some aspects of the experimental methods and associated uncertainties are highly correlated while others are independent. The results from both measurements broke new ground for PFNS measurements given their higher accuracy and more detailed study of corrections necessary for the measured quantity compared to existing literature measurements, and both will significantly impact PFNS nuclear data evaluations for the foreseeable future. Here, the focus of this work is to document a comparison of the results from these distinct measurements in terms of the acquired data, the PFNS results, and the measured average PFNS energies. While systematic differences between the PFNS results are present on the 1–3% level, the acquired data relative to each respective measurement at low incident neutron energies are in remarkable agreement, as are the conclusions regarding the magnitude and position of features in the PFNS relating to second-chance fission, third-chance fission, and pre-equilibrium neutron emission.
Explore the source record for details and available documents.
A neutron induced neutron emission experiment was conducted as the Los Alamos Neutron Science Center (LANSCE) facility at Los Alamos National Laboratory (LANL). In this experiment, a sample was placed in a well collimated neutron beam and was surrounded by an array of 28 fast neutron detectors (EJ-309). The experiment was performed with a neutron flight path of 21.5 m from the source to the sample, and 1 m from the sample to the detectors. The neutron emission from the sample was measured as a function of neutron time of flight covering an incident energy range from 0.7- 20 MeV. The samples included U-235, Pu-239, carbon (graphite), and blanks that matched the encapsulation of the sample. The measured samples were constantly cycled in and out of the neutron beam. This type of experiment measures neutron emission from all reactions occurring in the sample such as fission and elastic and inelastic scattering. Similar to the methodology previously developed at RPI, the measurements were compared with detailed simulations of the experiment using different cross section evaluations for the sample. The observed differences can be attributed to the evaluated neutron cross section and angular distributions. The carbon sample was used as a reference to validate both the experiment and simulation methodology and showed good agreement between experiments and simulations. A review of the experimental setup, analysis methods, and some of the results will be presented.
The neutron total cross sections σ tot of 16,18 O, 58 64 Ni, 103 Rh, and 112,124 Sn have been measured at the Los Alamos Neutron Science Center from low to intermediate energies (3 ≤ E lab ≤ 450 MeV) by leveraging wave-form-digitizer technology. The σ tot relative differences between isotopes are presented, revealing additional information about the isovector components needed for an accurate optical-model description away from stability. Digitizer-enabled σ tot -measurement techniques are discussed and a series of uncertainty-quantified dispersive optical model (DOM) analyses using these new data is presented, validating the use of the DOM for modeling light systems ( 16,18 O) and systems with open neutron shells ( 58,64 Ni and 112,124 Sn). Here, the valence-nucleon spectroscopic factors extracted for each isotope reaffirm the usefulness of high-energy proton reaction cross sections for characterizing depletion from the mean-field expectation.
Explore the source record for details and available documents.
While measurements of physical quantities contain an intrinsic absolute scale based on details of the experiment, sometimes only the value of each measured data point relative to the others, i.e., the shape, is of interest. Additionally, in contrast to absolute measurements of quantities like nuclear cross sections, shape measurements are unique in that the result is contained entirely in the relative value of each measured point with respect to all others. This fundamental attribute of shape data is sometimes discussed by data evaluators, but it is common that shape data are reported by experimenters with covariances directly from the raw data as though an absolute measurement has been performed, thereby misrepresenting the true knowledge of the measured shape. A normalization procedure must be carried out including careful covariance propagation in order to accurately represent the uncertainty in a measured shape. Known consequences of this procedure, such as the exclusion of constant fully-correlated uncertainties, are sometimes applied ad hoc to shape data. However, normalization also produces features of shape data that are otherwise difficult to apply, such as partial exclusion of strongly-correlated uncertainty sources, a redistribution of uncertainties across data points, and consistency of the covariance matrix obtained when combining separate shape measurements. In this study all of the above features are shown in a generalized fashion and exhibited using prompt fission neutron spectrum data from the Chi-Nu experiment with recommendations for analysis of future shape measurements.
Explore the source record for details and available documents.
For more than four decades, the United States has relied on the Los Alamos Neutron Science Center (LANSCE) accelerator to deliver high-energy, high-power proton beams in support of national security science. Today the LANSCE facility is a center for materials and nuclear research supporting National Nuclear Security Administration (NNSA) and Department of Energy (DOE) missions.
Explore the source record for details and available documents.
Explore the source record for details and available documents.
Background: Significant yield discrepancies (500-600%) were reported recently between experi- mental results and predictions (from the GEF model) and evaluations (from the JEFF-3.1.1 and ENDF/B-VII.1 libraries) for Mo and Sn fission-fragment yields in fast-neutron induced reactions on 238 U using γ-γ-γ coincidence spectroscopy. The model/evaluations also predict Mo and Sn fragments that are on average ~1 to 2 neutrons richer than the experimental results. Purpose: γ-γ-γ coincidence spectroscopy favors detection of higher-multiplicity γ-ray cascades. An alternative approach is determining the fragment yields using single-γ-ray spectroscopy, as it was attempted here for selected cases where it was feasible. Advantages/drawbacks in both approaches need to be understood and potential systematic errors in the experimental results should be addressed using theoretical models. Methods: Fast neutrons from the LANSCE WNR facility were used to induce fission on 238 U. The emitted γ rays were measured with the GEANIE spectrometer. Results: The yield of selected even-even fission fragments was determined. The selection was based on the ability to reliably determine excitation functions for the detected γ rays. Conclusions: Our single-γ-ray results provide better agreement between experiment and predictions/evaluations.
The goal of the Chi-Nu experiment at the Los Alamos Neutron Science Center is to measure the prompt fission neutron spectra from major actinides using a double time-of-flight method with a pulsed, white incoming neutron source. Fission events are detected with a parallel-plate avalanche counter and outgoing neutrons are detected with either a 6 Li-glass or liquid scintillator detector array for low- or high-energy neutrons, respectively. A detector response matrix for the interaction of neutrons with the experimental environment for neutrons measured with the Chi-Nu 6 Li-glass detector array has been calculated to obtain a full understanding of the measured Chi-Nu data and also to allow for nearly instantaneous production of simulated Chi-Nu data spectra. Prompt fission neutron spectra corresponding to 19 incoming neutron energy ranges from 0.7-20 MeV have been extracted using the ratio-of-ratios method with Chi-Nu 6 Li-glass data on the neutron-induced fission of 235 U.
In this study, the high statistical precision that can be achieved using modern data collection techniques implies that systematic uncertainties that were ignored or not considered for past experiments must now be explored. The folding of Monte Carlo simulations into experimental data analysis, which is becoming common practice, requires an estimate of the systematic uncertainty present in the experimental result from uncertainties in the library of cross sections used during the simulation, but this source of uncertainty is typically not quantified. Here we describe a method to estimate this systematic uncertainty by varying the cross sections used during simulation runtime. As opposed carrying out hundreds of sequential analog Monte Carlo simulations, this task was accomplished through a post-processing calculation of output from a single simulation that was run using the implicit-capture formalism available with MCNP ® 6.2 and the PTRAC output format.
Explore the source record for details and available documents.