Search NASA⌕ Search

Engineering topics

Dewji, Shaheen A.

Publications and source records attributed to Dewji, Shaheen A..

Computational multiphysics modeling of radioactive aerosol deposition in diverse human respiratory tract geometries

The evaluation of aerosol exposure relies on generic mathematical models that assume uniform particle deposition profiles over the human respiratory tract and do not account for subject-specific characteristics. Here we introduce a hybrid-automated computational workflow that generates personalized particle deposition profiles in 3D reconstructed human airways from computed tomography scans using Computational Fluid and Particle Dynamics simulations. This is the first large-scale study to consider realistic airways variability, where 380 lower and 40 upper human respiratory tract 3D geometries are reconstructed and parameterized. The data is clustered into nine groups using random forest regression. Computational fluid and particle dynamics simulations are conducted on these representative geometries using a realistic heavy-breathing respiratory cycle and radioactive iodine-131 as a source term. Monte Carlo radiation transport simulations are performed to obtain detailed energy deposition maps. Our findings emphasize the importance of personalized studies, as minor respiratory tract variations notably influence deposition patterns rather than global parameters of the lower airways, observing more than 30% variance in the mass deposition fraction.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Evaluation of neutron dosimetry capabilities with the MC-15 portable multiplicity counter

This work proposes a preliminary neutron dose rate estimation method for a neutron multiplicity detector through measurement- and simulation-based analyses. Uncharacterized neutron-emitting sources may be encountered in situations such as nuclear emergency response, safeguards, and treaty verification. These circumstances may present irradiation risk to personnel conducting field assay, search, and characterization measurements. It is therefore of interest to provide a field neutron dosimetry capability with the existing neutron multiplicity counting (NMC) capabilities. To date, no commercially-available neutron detection systems are capable of both accurate NMC and real-time neutron dosimetry. This work will focus on estimating dose rate using input from a single fielded NMC called the MC-15. The energy-dependent neutron detection efficiency response of the MC-15 was quantified in monoenergetic neutron simulations and evaluated in response to two neutron-emitting sources and to a polyethylene-moderated source. The results were compared to existing neutron dosimeters and established the proof of concept for further investigation of the MC-15 for dose estimation. Measurement results were also replicated in simulations; additional simulations were then conducted to expand upon the limited empirical data. The initial empirical results provided a conversion factor appropriate for use when measuring 252 Cf neutrons that is independent of polyethylene shielding presence and thickness. The simulated data sets were then used to evaluate a fit equation allowing estimation of the neutron dose rate for less restricted geometric configurations and dependent only on the distance between the source and the detector. Additionally, the energy dependence of the efficiency response indicates that further empirical evaluations could provide energy-dependent conversion factors for broader neutron dosimetry capabilities with a wider range of neutron-emitting sources.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Specific absorbed fractions for a revised series of the UF/NCI pediatric reference phantoms: internal photon sources

Assessment of radiation absorbed dose to internal organs of the body from the intake of radionuclides, or in the medical setting through the injection of radiopharmaceuticals, is generally performed based upon reference biokinetic models or patient imaging data, respectively. Biokinetic models estimate the time course of activity localized to source organs. The time-integration of these organ activity profiles are then scaled by the radionuclide S-value, which defines the absorbed dose to a target tissue per nuclear transformation in various source tissues. S-values are computed using established nuclear decay information (particle energies and yields), and a parameter termed the specific absorbed fraction (SAF). The SAF is the ratio of the absorbed fraction—fraction of particle energy emitted in the source tissue that is deposited in the target tissue—and the target organ mass. While values of the SAF may be computed using patient-specific or individual-specific anatomic models, they have been more widely available through the use of computational reference phantoms. In this study, we report on an extensive series of photon SAFs computed in a revised series of the University of Florida and the National Cancer Institute pediatric reference phantoms which have been modified to conform to the specifications embodied in the ICRP reference adult phantoms of Publication 110 (e.g. organs modeled, organ ID numbers, blood contribution to elemental compositions). Following phantom anatomical revisions, photon radiation transport simulations were performed using MCNPX v2.7 in each of the ten phantoms of the series—male and female newborn, 1 year old, 5 year old, 10 year old, and 15 year old—for 60 different tissues serving as source and/or target regions. A total of 25 photon energies were considered from 10 keV to 10 MeV along a logarithm energy grid. Detailed analyses were conducted of the relative statistical errors in the Monte Carlo target tissue energy deposition tallies at low photon energies and over all energies for source–target combinations at large intra-organ separation distances. Based on these analyses, various data smoothing algorithms were employed, including multi-point weighted data smoothing, and log–log interpolation at low energies (1 keV and 5 keV) using limiting SAF values based upon target organ mass to bound the interpolation interval. The final dataset is provided in a series of ten electronic supplemental files in MS Excel format. Finally, the results of this study were further used as the basis for assessing the radiative component of internal electron source SAFs as described in our companion paper (Schwarz et al 2021) for this same pediatric phantom series.

61 RADIATION PROTECTION AND DOSIMETRY↗

Specific absorbed fractions for a revised series of the UF/NCI pediatric reference phantoms: internal electron sources

Assessment of radiation absorbed dose to internal organs of the body from the intake of radionuclides, or in the medical setting through the injection of radiopharmaceuticals, is generally performed based upon reference biokinetic models or patient imaging data, respectively. Biokinetic models estimate the time course of activity localized to source organs. The time-integration of these organ activity profiles are then scaled by the radionuclide S-value, which defines the absorbed dose to a target tissue per nuclear transformation in various source tissues. S-values are computed using established nuclear decay information (particle energies and yields), and a parameter termed the specific absorbed fraction (SAF). The SAF is the ratio of the absorbed fraction—fraction of particle energy emitted in the source tissue that is deposited in the target tissue—and the target organ mass. While values of the SAF may be computed using patient-specific or individual-specific anatomic models, they have been more widely available through the use of computational reference phantoms. In this study, we report on an extensive series of photon SAFs computed in a revised series of the University of Florida and the National Cancer Institute pediatric reference phantoms which have been modified to conform to the specifications embodied in the ICRP reference adult phantoms of Publication 110 (e.g. organs modeled, organ ID numbers, blood contribution to elemental compositions). Following phantom anatomical revisions, photon radiation transport simulations were performed using MCNPX v2.7 in each of the ten phantoms of the series—male and female newborn, 1 year old, 5 year old, 10 year old, and 15 year old—for 60 different tissues serving as source and/or target regions. A total of 25 photon energies were considered from 10 keV to 10 MeV along a logarithm energy grid. Detailed analyses were conducted of the relative statistical errors in the Monte Carlo target tissue energy deposition tallies at low photon energies and over all energies for source–target combinations at large intra-organ separation distances. Based on these analyses, various data smoothing algorithms were employed, including multi-point weighted data smoothing, and log–log interpolation at low energies (1 keV and 5 keV) using limiting SAF values based upon target organ mass to bound the interpolation interval. The final dataset is provided in a series of ten electronic supplemental files in MS Excel format. Finally, the results of this study were further used as the basis for assessing the radiative component of internal electron source SAFs as described in our companion paper (Schwarz et al 2021) for this same pediatric phantom series.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Simulated Energy Response in a Multiplicity Detector

Neutron multiplicity analysis is used for many applications, including nonproliferation and criticality safety. Multiplicity detectors have advantages over total neutron counting as they provide the ability to assess both multiplication and mass in fissionable material. In addition, multiplicity detectors can generate real-time information, e.g., dose estimation. The ability to evaluate the detector efficiency in each application is of primary importance in producing meaningful analyses. Multiplicity detectors usually house 3 He tubes within a polyethylene moderator. If the tubes are located behind different thickness of polyethylene, they will have different energy responses. This paper assesses 3 He tube efficiency as a function of neutron energy for a specific multiplicity detector.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗