Field Measurement Results of the 15 T Nb 3 Sn Dipole Demonstrator MDPCT1b

A 15 T Nb 3 Sn dipole with cos-theta-type coils was developed to demonstrate a possible magnet design for a post-LHC proton-proton Collider. The magnet has 4-layer coils with 60-mm aperture, and has graded current density between the inner and outer layers to maximize performance. The coils are constrained by vertically-split, thick iron laminations, connected by aluminum Iclamps, and a thick stainless-steel skin. The magnet was previously tested at the Vertical Magnet Test Facility (VMTF) at Fermilab with reduced pre-load, and achieved record 14.1 T fields at maximum current. Now the magnet has been reassembled with full pre-load and has been cryogenically retested at VMTF. We report here on the magnetic measurements results of these tests, including field strength, geometrical harmonics, coil magnetization, and iron saturation characteristics of the demonstrator.

43 PARTICLE ACCELERATORS↗

Development and First Test of the 15 T Nb 3 Sn Dipole Demonstrator MDFCT1

Fermilab in the framework of the U.S. Magnet Development Pro-gram (US-MDP) has developed and fabricated a 15 T Nb 3 Sn dipole demonstrator for a post-LHC hadron collider. In June 2019 the magnet was tested and reached a world record field in the aperture of 14.1T at 4.5 K.

43 PARTICLE ACCELERATORS↗

First Field Quality Measurements of a 15 T Nb3Sn Dipole Demonstrator

Outline: Data collection; Magnetic Measurement System; Measurement sensitivity; Centering Corrections; Measurement discussion; Transfer Function (magnitude of the field); Loop (Dynamic effects, eddy current); Z-scan (behavior along magnet length); Harmonics from Stair Step (geometric harmonics); Comparison with Simulation; Decay and Snapback; Summary

43 PARTICLE ACCELERATORS↗

Vertical Magnetic Measurement System Commis-sioning and First Measurements of the First Full-Length Prototype Quadrupole Magnet for the LHC Hi-Lumi Upgrade

This paper will report the commissioning of the vertical magnetic measurement system and the warm (room temperature) and cold (cryogenic) magnetic field measurements of the first full-length (4.2 m) quadrupole built by the US Accelerator Upgrade Project (AUP) project (formerly the LARP collaboration) for the high luminosity upgrade of the Large Hadron Collider at CERN. The magnet, designated MQXFAP2, is a prototype preceding production for the AUP Accelerator Upgrade Project (AUP). AUP will provide ten 8.4 m superconducting insertion region (IR) quadrupoles for the Hi-Lumi Upgrade. The 8.4 m quadrupoles will be built by assembling two 4.2 m magnets in a single cryostat. Agreement between BNL’s and LBNL’s warm measurement data has indicated that the upgraded vertical magnetic measurement system at BNL is ready for MQXFA magnet production testing. The cold magnetic measurement has been performed and preliminary data analysis has been conducted. The measured data indicates that the MQXFAP2 magnet has good magnetic field which meets the preliminary MQXFA magnet acceptance criteria.

43 PARTICLE ACCELERATORS↗

Progress on HL-LHC Nb 3 Sn Magnets

The high-luminosity Large Hadron Collider (HL-LHC) project aims at allowing to increase the collisions in the LHC by a factor of ten in the decade 2025-2035. One essential element is the superconducting magnet around the interaction region points, where the large aperture magnets will be installed to allow to further reduce the beam size in the interaction point. The core of this upgrade is the Nb 3 Sn triplet, made up of 150-mm aperture quadrupoles in the range of 7-8 m. The project is being shared between the European Organization for Nuclear Research and the US Accelerator Upgrade Program, based on the same design, and on the two strand technologies. The project is ending the short model phase, and entering the prototype construction. We will report on the main results of the short model program, including the quench performance and field quality. A second important element is the 11 T dipole that replaces a standard dipole making space for additional collimators. The magnet is also ending the model development and entering the prototype phase. A critical point in the design of this magnet is the large current density, allowing increase of the field from 8 to 11 T with the same coil cross section as in the LHC dipoles. This is also the first two-in-one Nb 3 Sn magnet developed so far. We will report the main results on the test and the critical aspects.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Superconducting Magnet Performance in LCLS-II Cryomodules

New LCLS-II Linear Superconducting Accelerator Cry-omodules are under construction at Fermilab. Installed in-side each SCRF Cryomodule is a superconducting magnet package to focus and steer an electron beam. The magnet package is an iron dominated configuration with conduc-tively cooled racetrack-type quadrupole and dipole coils. For easier installation the magnet can be split in the vertical plane. Initially the magnet was tested in a liquid helium bath, and high precision magnetic field measurements were performed. The first (prototype) Cryomodule with the magnet inside was built and successfully tested at Fermilab test facility. In this paper the magnet package is discussed, the Cryomodule magnet test results and current leads con-duction cooling performance are presented. So far magnets in nine Cryomodules were successfully tested at Fermilab.

Kashikhin, V.↗

A high-precision miniaturized rotating coil transducer for magnetic measurements

A miniaturized Printed Circuit Board (PCB) sensing coil, jointly developed by CERN and Fermilab for measuring the field of small-gap (less than 10 mm) accelerator magnets, is illustrated. A sensing coil array, with a scheme for compensating the main field when measuring the harmonic error components, hosted on a synthetic sapphire-based transducer, is presented. Key innovating features are (i) very-small size, both for the sensing coil array (thickness of 1.380 mm) and for the transducer (overall diameter of 7.350 mm), (ii) metrological performance, namely accuracy (more than five times better than state of the art), and 1-sigma repeatability (ten times better on harmonics with amplitude less than 100 ppm), and (iii) manufacturing technology of both the coil array (13 double layers aligned within 10 μm), and the sapphire support (concentricity, the most important uncertainty source for rotating coils, 3 μm of uncertainty, namely one order of magnitude better than fiberglass support). After stating the measurement problem, the design of the transducer and a case study of a two-layer PCB sensor array are also illustrated. Then, the prototyping and quality control of both the sensor and the transducer are discussed. Furthermore, the calibration and the results obtained with a prototype setup at Fermilab are presented. Finally, in the appendix, the theory of the rotating coil, the sensor geometry, and the harmonic compensation are briefly reviewed for the reader easiness.

06.20.fb/calibration↗

Magnetic Measurements of Storage Ring Magnets for the APS Upgrade Project

Extensive prototyping of storage ring magnets is ongoing at the Advanced Photon Source (APS) in support of the APS Multi-Bend Achromat (MBA) upgrade project (APS-U) [1]. As part of the R&D activities four quadrupole magnets with slightly different geometries and pole tip materials, and one sextupole magnet with vanadium permendur (VP) pole tips were designed, built and tested. Magnets were measured individually using a rotating coil and a Hall probe for detailed mapping of the magnetic field. Magnets were then assembled and aligned relative to each other on a steel support plate and concrete plinth using precision machined surfaces to gain experience with the alignment method chosen for the APS-U storage ring magnets. The required alignment of magnets on a common support structure is 30 μm rms. Measurements of magnetic field quality, strength and magnet alignment after subjecting the magnets and assemblies to different tests are presented.

Doose, C.↗

Magnetic Measurements of the First Nb 3 Sn Model Quadrupole (MQXFS) for the High-Luminosity LHC

The US LHC Accelerator Research Program (LARP) and CERN are developing high-gradient Nb 3 Sn magnets for the High Luminosity LHC interaction regions. Magnetic measurements of the first 1.5 m long, 150 mm aperture model quadrupole, MQXFS1, were performed during magnet assembly at LBNL, as well as during cryogenic testing at Fermilab’s Vertical Magnet Test Facility. This paper reports on the results of these magnetic characterization measurements, as well as on the performance of new probes developed for the tests.

43 PARTICLE ACCELERATORS↗

Superconducting focusing lenses for the SSR-1 cryomodule of PXIE test stand at Fermilab

Five solenoid-based focusing lenses designed for use inside the SSR1 cryomodule of the PXIE test stand at Fermilab have been fabricated and tested. In addition to a focusing solenoid, each lens is equipped with a set of windings that generate magnetic field in the transverse plane and can be used in the steering dipole mode or as a skew quadrupole corrector. The lenses will be installed between superconducting cavities in the cryomodule, so getting sufficiently low fringe magnetic field was one of the main design requirements. Beam dynamics simulations indicated a need for high accuracy positioning of the lenses in the cryomodule, which triggered a study towards understanding uncertainties of the magnetic axis position relative to the geometric features of the lens. Furthermore, this report summarizes the efforts towards certification of the lenses, including results of performance tests, fringe field data, and uncertainty of the magnetic axis position.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Performance of the First Short Model 150-mm-Aperture Nb3Sn Quadrupole MQXFS for the High-Luminosity LHC Upgrade

LHC Accelerator Research Program (LARP) and CERN combined their efforts in developing Nb3Sn magnets for the high-luminosity LHC upgrade. The ultimate goal of this collaboration is to fabricate large aperture Nb 3Sn quadrupoles for the LHC interaction regions. These magnets will replace the present 70-mm-Aperture NbTi quadrupole triplets for expected increase of the LHC peak luminosity up to 5 × 10 34 cm -2 s -1 or more. Over the past decade, LARP successfully fabricated and tested short and long models of 90 and 120-mm-Aperture Nb3Sn quadrupoles. Recently, the first short model of 150-mm-diameter quadrupole MQXFS was built with coils fabricated both by LARP and CERN. The magnet performance was tested at Fermilab's vertical magnet test facility. Here, this paper reports the test results, including the quench training at 1.9 K, ramp rate and temperature dependence, as well as protection heater studies.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Test results of the LARP Nb$_3$Sn quadrupole HQ03a

The US LHC Accelerator Research Program (LARP) has been developing $Nb_3Sn$ quadrupoles of progressively increasing performance for the high luminosity upgrade of the Large Hadron Collider. The 120 mm aperture High-field Quadrupole (HQ) models are the last step in the R&D phase supporting the development of the new IR Quadrupoles (MQXF). Three series of HQ coils were fabricated and assembled in a shell-based support structure, progressively optimizing the design and fabrication process. The final set of coils consistently applied the optimized design solutions, and was assembled in the HQ03a model. Furthermore, this paper reports a summary of the HQ03a test results, including training, mechanical performance, field quality and quench studies.

43 PARTICLE ACCELERATORS↗

Performance of conduction cooled splittable superconducting magnet package for linear accelerators

New Linear Superconducting Accelerators need a superconducting magnet package installed inside SCRF Cryomodules to focus and steer electron or proton beams. A superconducting magnet package was designed and built as a collaborative effort of FNAL and KEK. The magnet package includes one quadrupole, and two dipole windings. It has a splittable in the vertical plane configuration, and features for conduction cooling. The magnet was successfully tested at room temperature, in a liquid He bath, and in a conduction cooling experiment. The paper describes the design and test results including: magnet cooling, training, and magnetic measurements by rotational coils. Furthermore, the effects of superconductor and iron yoke magnetization, hysteresis, and fringe fields are discussed.

43 PARTICLE ACCELERATORS↗

Mu2e transport solenoid prototype tests results

The Fermilab Mu2e experiment has been developed to search for evidence of charged lepton flavor violation through the direct conversion of muons into electrons. The transport solenoid is an s-shaped magnet which guides the muons from the source to the stopping target. It consists of fifty-two superconducting coils arranged in twenty-seven coil modules. A full-size prototype coil module, with all the features of a typical module of the full assembly, was successfully manufactured by a collaboration between INFN-Genoa and Fermilab. The prototype contains two coils that can be powered independently. In order to validate the design, the magnet went through an extensive test campaign. Warm tests included magnetic measurements with a vibrating stretched wire, electrical and dimensional checks. As a result, the cold performance was evaluated by a series of power tests as well as temperature dependence and minimum quench energy studies.

43 PARTICLE ACCELERATORS↗

Longitudinal Gradient Dipole Magnet Prototype for APS at ANL

We planned an upgrade of the Advanced Photon Source at Argonne National Laboratory (ANL). The main goal of the upgrade is to improve the storage ring performance based on more advanced optics. One of the key magnet system elements is bending dipole magnets having a field strength change along the electron beam path. Moreover, a prototype of one such longitudinal gradient dipole magnet has been designed, built, and measured in a collaborative effort of ANL and Fermilab. Our paper discusses various magnetic design options, the selected magnet design, and the fabrication technology. The prototype magnet has been measured by rotational coils, a stretched wire, and a Hall probe. Measurement results are discussed and compared with simulations.

43 PARTICLE ACCELERATORS↗

Summary of the Persistent Current Effect Measurements in Nb 3 Sn and NbTi Accelerator Magnets at Fermilab

In the past 10 years, Fermilab has been executing an intensive R&D program on accelerator magnets based on Nb 3 Sn superconductor technology. This R&D effort includes dipole and quadrupole models for different programs, such as LARP and 11 T dipoles for the LHC high-luminosity upgrade. Before the Nb 3 Sn R&D program, Fermilab was involved in the production of the low-beta quadrupole magnets for LHC based on the NbTi superconductor. Additionally, during the 2003-2005 campaign to optimize the operation of the Tevatron, a large number of Tevatron magnets were re-measured. As a result of this field analysis, a systematic study of the persistent current decay and snapback effect in these magnets was performed. This paper summarizes the result of this study and presents a comparison between Nb 3 Sn and NbTi dipoles and quadrupoles.

43 PARTICLE ACCELERATORS↗

Validation of Finite-Element Models of Persistent-Current Effects in Nb 3 Sn Accelerator Magnets

Persistent magnetization currents are induced in superconducting filaments during the current ramping in magnets. The resulting perturbation to the design magnetic field leads to field quality degradation, in particular at low field where the effect is stronger relative to the main field. The effects observed in NbTi accelerator magnets were reproduced well with the critical-state model. However, this approach becomes less accurate for the calculation of the persistent-current effects observed in Nb 3 Sn accelerator magnets. Here a finite-element method based on the measured strand magnetization is validated against three state-of-art Nb3Sn accelerator magnets featuring different subelement diameters, critical currents, magnet designs and measurement temperatures. The temperature dependence of the persistent-current effects is reproduced. Based on the validated model, the impact of conductor design on the persistent current effects is discussed. The performance, limitations and possible improvements of the approach are also discussed.

36 MATERIALS SCIENCE↗