Search NASA⌕ Search

Engineering topics

Didla, Shimi Praveena

Publications and source records attributed to Didla, Shimi Praveena.

Comparison of Projections for a Short-Term Release, CAP88 vs NARAC

The purpose of this study was to compare the projected dose using different plume models, evaluating a short duration release of tritium to the 16 compliance sectors and 4 additional points of interest using local meteorology. This report is written as guidance to the decision makers when reviewing this specific Gaussian plume model intended for radiological dose assessment and regulatory compliance, called CAP88 1 , as compared to a more-complex model designed for emergency response. The emergency response model, NARAC 2 , can be used to supplement the CAP88 compliance model evaluations, since NARAC is intended for use in situations where releases are shorter in duration and have increased complexity in terrain and meteorology.

54 ENVIRONMENTAL SCIENCES↗

Annual Performance Testing of Tracer Gas Detectors for use in Radionuclide NESHAP Compliance Testing

Los Alamos National Laboratory’s (LANL’s) compliance with Radionuclide NESHAP0F 1 regulations is managed by the Radioactive Air Emissions Management (RAEM) team, part of LANL’s Compliance Programs group (EPC-CP). One area of the Radionuclide NESHAP addresses requirements for siting a stack sample system. Prior to commissioning a new stack sampling system, the ANSI Standard for stack sampling requires that the stack sample location must meet several criteria, including uniform mixing of tracer gas (sulfur hexafluoride, SF 6 ) and tracer aerosol (liquid oil droplets) in the air stream. This memorandum will specifically focus on the tracer gas portion of the ANSI Standard. For these mix tests, tracer gas is injected into the stack air stream and the resulting air concentrations are measured across the plane of the stack at the proposed sampling location. The coefficient of variation of the media concentration must be under 20% when evaluated over the central 2/3 area of the stack or duct.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Evaluation of Naturally Occurring Be-7 Activity on LANL Stack Filter Clumps

Los Alamos National Laboratory (LANL) is responsible for providing solutions to challenging issues through multidisciplinary science, engineering, and technology that impact national security. As part of the Radioactive Air Emissions Management (RAEM) Team, it is our responsibility to ensure LANL operates within the requirements of the Code of Federal Regulations 40 CFR 61, Subpart H, National Emission Standards for Emissions of Radionuclides Other Than Radon From Department of Energy Facilities (Rad-NESHAP). The standard states, “Emissions of radionuclides to the ambient air from Department of Energy facilities shall not exceed those amounts that would cause any member of the public to receive in any year an effective dose equivalent of 10 mrem/yr” (EPA, 2002) During a routine assessment of LANL’s Rad-NESHAP compliance program, an opportunity for improvement was identified that addresses the evaluation of routine stack samples which potentially have naturally occurring radioactive materials (NORM) on the filter media. In the past and based on professional judgment, detections of NORM such as K-40 and Be-7 typically were rejected from the analytical results. The assessment finding suggested developing a technical criterion to ensure that such rejections were justified, comparing actual measured values with anticipated NORM concentrations for various stacks located at LANL. The significance of accepting or rejecting samples as “true” or “NORM” and its impact on the RAEM’s mission and compliance to the regulations is explained later in the document. Additionally, this document will describe the process and calculations for how such results are to be accepted as actual samples “true positive” or rejected as NORM.

98 NUCLEAR DISARMAMENT, SAFEGUARDS, AND PHYSICAL P↗