Search NASA⌕ Search

Engineering topics

Ding, K.

Publications and source records attributed to Ding, K..

Accessing new physics with an undoped, cryogenic CsI CEvNS detector for COHERENT at the SNS

We consider the potential for a 10 kg undoped cryogenic CsI detector operating at the Spallation Neutron Source to measure coherent elastic neutrino-nucleus scattering and its sensitivity to discover new physics beyond the standard model (BSM). Through a combination of increased event rate, lower threshold, and good timing resolution, such a detector would significantly improve on past measurements. We considered tests of several BSM scenarios such as neutrino nonstandard interactions and accelerator-produced dark matter. This detector’s performance was also studied for relevant questions in nuclear physics and neutrino astronomy, namely the weak charge distribution of Cs and I nuclei and detection of neutrinos from a core-collapse supernova. Published by the American Physical Society 2024

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Measurement of Electron-Neutrino Charged-Current Cross Sections on 127 I with the COHERENT NaI$ν$E Detector

Using an 185-kg NaI[Tl] array, COHERENT has measured the inclusive electron-neutrino chargedcurrent cross section on 127 I with pion decay-at-rest neutrinos produced by the Spallation Neutron Source at Oak Ridge National Laboratory. Iodine is one the heaviest targets for which low-energy (≤ 50 MeV) inelastic neutrino-nucleus processes have been measured, and this is the first measurement of its inclusive cross section. After a five-year detector exposure, COHERENT reports a flux-averaged cross section for electron neutrinos of ${9.2}_{–1.8}^{+2.1}$ × 10 –40 cm 2 . This corresponds to a value that is ~41% lower than predicted using the MARLEY event generator with a measured Gamow-Teller strength distribution. In addition, the observed visible spectrum from charged-current scattering on 127 I has been measured between 10 and 55 MeV, and the exclusive zero-neutron and one-or-more-neutron emission cross sections are measured to be ${5.2}_{–3.1}^{+3.4}$ × 10 –40 and ${2.2}_{—2.2}^{+3.5}$ × 10 –40 cm 2 , respectively.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Measurement of scintillation response of CsI[Na] to low-energy nuclear recoils by COHERENT

Here, we present results of several measurements of CsI[Na] scintillation response to 3–60 keV energy nuclear recoils performed by the COHERENT collaboration using tagged neutron elastic scattering experiments and an endpoint technique. Earlier results, used to estimate the coherent elastic neutrino-nucleus scattering (CEvNS) event rate for the first observation of this process achieved by COHERENT at the Spallation Neutron Source (SNS), have been reassessed. We discuss corrections for the identified systematic effects and update the respective uncertainty values. The impact of updated results on future precision tests of CEvNS is estimated. We scrutinize potential systematic effects that could affect each measurement. In particular we confirm the response of the H11934-200 Hamamatsu photomultiplier tube (PMT) used for the measurements presented in this study to be linear in the relevant signal scale region.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Monitoring the SNS basement neutron background with the MARS detector

Here, we present the analysis and results of the first dataset collected with the MARS neutron detector deployed at the Oak Ridge National Laboratory Spallation Neutron Source (SNS) for the purpose of monitoring and characterizing the beam-related neutron (BRN) background for the COHERENT collaboration. MARS was positioned next to the COH-CsI coherent elastic neutrino-nucleus scattering detector in the SNS basement corridor. This is the basement location of closest proximity to the SNS target and thus, of highest neutrino flux, but it is also well shielded from the BRN flux by infill concrete and gravel. Furthermore, these data show the detector registered roughly one BRN per day. Using MARS' measured detection efficiency, the incoming BRN flux is estimated to be 1.20 ± 0.56 neutrons/m 2 /MWh for neutron energies above ~3.5 MeV and up to a few tens of MeV. We compare our results with previous BRN measurements in the SNS basement corridor reported by other neutron detectors.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Deterministic modeling of hybrid nonlinear effects in epsilon-near-zero thin films

In nonlinear optics, significant effort is concentrated on improving the strength and efficiency of interactions; however, experimentally investigating nonlinear materials is a complex, time-consuming, and costly investment. Moreover, it is often challenging to isolate, study, and optimize material parameters in an experiment due to complexities in the growth process. Recently, epsilon-near-zero materials have received a great deal of attention as promising nonlinear optical materials, but like many up-and-coming materials, the ability to explore and optimize their properties has been challenging. Here, we establish a framework to rapidly evaluate the performance of nonlinear epsilon-near-zero materials for both inter- and intraband effects in silico, requiring only an energy-momentum (E-k) diagram, linear optical properties, and experimental conditions. Measured nonlinear reflection and transmission in gallium-doped zinc oxide films are compared to the numerical framework for both intra- and interband excitation to verify accuracy across wavelength and irradiance while two figures of merit (FoMs) are introduced to quickly evaluate the performance of films without a full numerical framework. This capability is used to predict the performance of highly doped gallium nitride, cadmium oxide, zinc oxide, and indium tin oxide films, and efficient intra- and interband operation conditions are identified. Through this numerical framework and the FoMs, the exploration of unstudied epsilon-near-zero materials is enabled without the need for a nonlinear experiment, thereby accelerating the search for more efficient nonlinear materials and excitation conditions.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

A D$_2$O detector for flux normalization of a pion decay-at-rest neutrino source

We report on the technical design and expected performance of a 592 kg heavy-water-Cherenkov detector to measure the absolute neutrino flux from the pion-decay-at-rest neutrino source at the Spallation Neutron Source (SNS) at Oak Ridge National Laboratory (ORNL). The detector will be located roughly 20 m from the SNS target and will measure the neutrino flux with better than 5% statistical uncertainty in 2 years. This heavy-water detector will serve as the first module of a two-module detector system to ultimately measure the neutrino flux to 2–3% at both the First Target Station and the planned Second Target Station of the SNS. This detector will significantly reduce a dominant systematic uncertainty for neutrino cross-section measurements at the SNS, increasing the sensitivity of searches for new physics.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

MO-DE-210-03: Ultrasound imaging is an attractive method for image guided radiation treatment (IGRT), by itself or to complement other imaging modalities

Ultrasound imaging is an attractive method for image guided radiation treatment (IGRT), by itself or to complement other imaging modalities. It is inexpensive, portable and provides good soft tissue contrast. For challenging soft tissue targets such as pancreatic cancer, ultrasound imaging can be used in combination with pre-treatment MRI and/or CT to transfer important anatomical features for target localization at time of treatment. The non-invasive and non-ionizing nature of ultrasound imaging is particularly powerful for intra-fraction localization and monitoring. Recognizing these advantages, efforts are being made to incorporate novel robotic approaches to position and manipulate the ultrasound probe during irradiation. These recent enabling developments hold potential to bring ultrasound imaging to a new level of IGRT applications. However, many challenges, not limited to image registration, robotic deployment, probe interference and image acquisition rate, need to be addressed to realize the full potential of IGRT with ultrasound imaging. Learning Objectives: Understand the benefits and limitations in using ultrasound to augment MRI and/or CT for motion monitoring during radiation therapy delivery. Understanding passive and active robotic approaches to implement ultrasound imaging for intra-fraction monitoring. Understand issues of probe interference with radiotherapy treatment. Understand the critical clinical workflow for effective and reproducible IGRT using ultrasound guidance. The work of X.L. is supported in part by Elekta; J.W. and K.D. is supported in part by a NIH grant R01 CA161613 and by Elekta; D.H. is support in part by a NIH grant R41 CA174089.

60 APPLIED LIFE SCIENCES↗

Coupling and single-photon purity of a quantum dot-cavity system studied using hydrostatic pressure

We propose an approach to tune the emission of a single semiconductor quantum dot (QD) to couple with a planar cavity using hydrostatic pressure without inducing temperature variation during the process of measurement. Based on this approach, we studied the influence of cavity mode on the single-photon purity of an InAs/GaAs QD. Our measurement demonstrates that the single-photon purity degrades when the QD emission resonates with the cavity mode. This negative influence of the planar cavity is mainly caused by the cavity feeding effect.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Effect of graphene on photoluminescence properties of graphene/GeSi quantum dot hybrid structures

Graphene has been discovered to have two effects on the photoluminescence (PL) properties of graphene/GeSi quantum dot (QD) hybrid structures, which were formed by covering monolayer graphene sheet on the multilayer ordered GeSi QDs sample surfaces. At the excitation of 488 nm laser line, the hybrid structure had a reduced PL intensity, while at the excitation of 325 nm, it had an enhanced PL intensity. The attenuation in PL intensity can be attributed to the transferring of electrons from the conducting band of GeSi QDs to the graphene sheet. The electron transfer mechanism was confirmed by the time resolved PL measurements. For the PL enhancement, a mechanism called surface-plasmon-polariton (SPP) enhanced absorption mechanism is proposed, in which the excitation of SPP in the graphene is suggested. Due to the resonant excitation of SPP by incident light, the absorption of incident light is much enhanced at the surface region, thus leading to more exciton generation and a PL enhancement in the region. The results may be helpful to provide us a way to improve optical properties of low dimensional surface structures.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Photoluminescence studies on self-organized 1.55-μm InAs/InGaAsP/InP quantum dots under hydrostatic pressure

We report an experimental study on the optical properties of the self-organized 1.55-μm InAs/InGaAsP/InP quantum dots (QDs) under hydrostatic pressure up to 9.5 GPa at 10 K. The obtained pressure coefficients of emissions from InGaAsP to InAs QDs are 92 meV/GPa and 76 meV/GPa, respectively. Their photoluminescence intensities are found to decrease significantly with increasing pressure due to the pressure-induced Γ-X mixing of InGaAsP at about 8.5 GPa. The lifetime of excitonic emission from QDs decreases from about 1.15 at zero pressure to about 1.05 ns at 7.41 GPa. The wavelength of QD emission was tuned from 1.55 to 0.9 μm by applying a pressure of 8 GPa, displaying the feasibility for indirectly characterizing the individual InAs/InGaAsP/InP QDs of 1.55-μm emission (at zero pressure) under high-pressure using silicon avalanche photodiode.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗