Search NASA⌕ Search

Engineering topics

Ding, Leibo

Publications and source records attributed to Ding, Leibo.

Characterizations of a KHz Pulsed Laser Detection System

A KHz Pulsed Laser Detection System was developed employing the concept of charge integration with an electrometer, in the NASA Goddard Space Flight Center, Code 618 Calibration Lab for the purpose of using the pulsed lasers for radiometric calibration. Comparing with traditional trans-impedance (current-voltage conversion) detection systems, the prototype of this system consists of a UV-Enhanced Si detector head, a computer controlled shutter system and a synchronized electrometer. The preliminary characterization work employs light sources running in either CW or pulsed mode. We believe this system is able to overcome the saturation issue when a traditional trans-impedance detection system is used with the pulsed laser light source, especially with high peak-power pulsed lasers operating at kilohertz repetition rates (e.g. Ekspla laser or KHz OPO). The charge integration mechanism is also expected to improve the stability of measurements for a pulsed laser light source overcoming the issue of peak-to-peak stability. We will present the system characterizations including signal-to-noise ratio and uncertainty analysis and compare results against traditional trans-impedance detection systems.

Ding, Leibo↗

Characterizations of a KHz Pulsed Laser Detection System

A KHz Pulsed Laser Detection System was developed employing the concept of charge integration with an electrometer, in the NASA Goddard Space Flight Center, Code 618 Calibration Lab for the purpose of using the pulsed lasers for radiometric calibration. Comparing with traditional trans-impedance (current-voltage conversion) detection systems, the prototype of this system consists of a UV-Enhanced Si detector head, a computer controlled shutter system and a synchronized electrometer. The preliminary characterization work employs light sources running in either CW or pulsed mode. We believe this system is able to overcome the saturation issue when a traditional trans-impedance detection system is used with the pulsed laser light source, especially with high peak-power pulsed lasers operating at kilohertz repetition rates (e.g. Ekspla laser or KHz OPO). The charge integration mechanism is also expected to improve the stability of measurements for a pulsed laser light source overcoming the issue of peak-to-peak stability. We will present the system characterizations including signal-to-noise ratio and uncertainty analysis and compare results against traditional trans-impedance detection systems.

Ding, Leibo↗

Spectralon BRDF and DHR Measurements in Support of Satellite Instruments Operating Through Shortwave Infrared

Satellite instruments operating in the reflective solar wavelength region require accurate and precise determination of the Bidirectional Reflectance Distribution Functions (BRDFs) of the laboratory and flight diffusers used in their pre-flight and on-orbit calibrations. This paper advances that initial work and presents a comparison of spectral Bidirectional Reflectance Distribution Function (BRDF) and Directional Hemispherical Reflectance (DHR) of Spectralon*, a common material for laboratory and onorbit flight diffusers. A new measurement setup for BRDF measurements from 900 nm to 2500 nm located at NASA Goddard Space Flight Center (GSFC) is described. The GSFC setup employs an extended indium gallium arsenide detector, bandpass filters, and a supercontinuum light source. Comparisons of the GSFC BRDF measurements in the ShortWave InfraRed (SWIR) with those made by the NIST Spectral Trifunction Automated Reference Reflectometer (STARR) are presented. The Spectralon sample used in this study was 2 inch diameter, 99% white pressed and sintered Polytetrafluoroethylene (PTFE) target. The NASA/NIST BRDF comparison measurements were made at an incident angle of 0 deg and viewing angle of 45 deg. Additional BRDF data not compared to NIST were measured at additional incident and viewing angle geometries and are not presented here The total combined uncertainty for the measurement of BRDF in the SWIR range made by the GSFC scatterometer is less than 1% (k=1). This study is in support of the calibration of the Joint Polar Satellite System (JPSS) Radiation Budget Instrument (RBI) and Visible Infrared Imaging Radiometer Suite (VIIRS) of and other current and future NASA remote sensing missions operating across the reflected solar wavelength region.

Georgiev, Georgi T.↗

jasonSWIR Calibration of Spectralon Reflectance Factor

Satellite instruments operating in the reflective solar wavelength region require accurate and precise determination of the Bidirectional Reflectance Factor (BRF) of laboratory-based diffusers used in their pre-flight and on-orbit radiometric calibrations. BRF measurements are required throughout the reflected-solar spectrum from the ultraviolet through the shortwave infrared. Spectralon diffusers are commonly used as a reflectance standard for bidirectional and hemispherical geometries. The Diffuser Calibration Laboratory (DCaL) at NASA's Goddard Space Flight Center is a secondary calibration facility with reflectance measurements traceable to those made by the Spectral Tri-function Automated Reference Reflectometer (STARR) facility at the National Institute of Standards and Technology (NIST). For more than two decades, the DCaL has provided numerous NASA projects with BRF data in the ultraviolet (UV), visible (VIS) and the Near infraRed (NIR) spectral regions. Presented in this paper are measurements of BRF from 1475nm to 1625nm obtained using an indium gallium arsenide detector and a tunable coherent light source. The sample was a 2 inch diameter, 99% white Spectralon target. The BRF results are discussed and compared to empirically generated data from a model based on NIST certified values of 6deg directional/hemispherical spectral reflectance factors from 900nm to 2500nm. Employing a new NIST capability for measuring bidirectional reflectance using a cooled, extended InGaAs detector, BRF calibration measurements of the same sample were also made using NIST's STARR from 1475nm to 1625nm at an incident angle of 0deg and at viewing angles of 40deg, 45deg, and 50deg. The total combined uncertainty for BRF in this ShortWave Infrared (SWIR) range is less than 1%. This measurement capability will evolve into a BRF calibration service in SWIR region in support of NASA remote sensing missions. Keywords: BRF, BRDF, Calibration, Spectralon, Reflectance, Remote Sensing.

Georgiev, Georgi T.↗

Development and Performance of a Filter Radiometer Monitor System for Integrating Sphere Sources

The NASA Goddard Space Flight Center (GSFC) Radiometric Calibration Laboratory (RCL) maintains several large integrating sphere sources covering the visible to the shortwave infrared wavelength range. Two critical, functional requirements of an integrating sphere source are short and long-term operational stability and repeatability. Monitoring the source is essential in determining the origin of systemic errors, thus increasing confidence in source performance and quantifying repeatability. If monitor data falls outside the established parameters, this could be an indication that the source requires maintenance or re-calibration against the National Institute of Science and Technology (NIST) irradiance standard. The GSFC RCL has developed a Filter Radiometer Monitoring System (FRMS) to continuously monitor the performance of its integrating sphere calibration sources in the 400 to 2400nm region. Sphere output change mechanisms include lamp aging, coating (e.g. BaSO4) deterioration, and ambient water vapor level. The Filter Radiometer Monitor System (FRMS) wavelength bands are selected to quantify changes caused by these mechanisms. The FRMS design and operation are presented, as well as data from monitoring four of the RCL s integrating sphere sources.

Ding, Leibo↗