Search NASA⌕ Search

Engineering topics

Dixon, Derek R.

Publications and source records attributed to Dixon, Derek R..

Vitrification of Hanford Tank 241-AN-107 Waste and Equivalent Simulant

Hanford Site nuclear waste is to be vitrified at the Waste Treatment and Immobilization Plant (WTP), which is a part of the safe and efficient retrieval, treatment, and disposal mission of the U.S. Department of Energy Office of River Protection. Hanford tank 241-AN-107 (referred to herein as AN-107) is one of the initial Hanford radioactive tank wastes planned to be processed and vitrified. A portion of AN-107 waste was retrieved by Washington River Protection Solutions, LLC (WRPS) and transferred to Pacific Northwest National Laboratory (PNNL). Compared to previously received and vitrified wastes (AP-107, AP-105, and AP-105), the concentration of organics in AN-107 was greater by an order of magnitude, while the activity of radionuclides was multiple orders of magnitude greater.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Glass formulation and lab-scale testing of glasses designed for in-can Melter and in-container Vitrification of high-assay low-enriched uranium aqueous polishing Raffinate waste

Glasses were designed for processing a nuclear waste from aqueous polishing of high-assay low-enriched uranium using either In-Can Melter (ICM) or GeoMelt® In-Container Vitrification™ (ICV) technologies, which operate at temperatures of T p ≤ 1100 °C and T p ≤ 1450 °C, respectively. Due to the different operating conditions, the melt and glass properties were optimized differently for each technology. Each glass was designed to optimize for maximum waste loading while simultaneously satisfying processing (e.g., crystallization, viscosity, and conductivity) and product quality (e.g., durability, hazard characteristic, and crystal content) constraints. Here, the raffinate waste contains high nitric acid (4 M) and low total solids (9 g·L -1 ) concentrations. Feed preparation processes were tested to facilitate concentration and nitrate destruction/removal while controlling redox of the melter feed. A successful feed process including sugar addition and spray-drying was performed to generate an adequate melter feed for ICV processing.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Nitrate and Nitrite at Hanford – From Tanks to Natural Attenuation

Washington River Protection Solutions, LLC (WRPS) contracted Pacific Northwest National Laboratory (PNNL) in support of their maturation testing and analysis to develop and deploy an ambient temperature solidification/stabilization process for low-activity waste (LAW) (referred to as “grout” in this report). The intent of this effort is to support a sample-and-send regulatory and processing strategy in the Hanford 200 West Area, specifically considering grout waste forms disposal at Hanford in the Integrated Disposal Facility (IDF). Currently the disposal of grouted LAW is not an option because the IDF is not permitted to receive this waste form. The material presented in this report is intended to help inform the U.S. Department of Energy (DOE), the site operating contractors, regulatory agencies, and stakeholders of the future implications of IDF disposal of a grouted LAW waste form, specifically for the behavior of nitrate (NO 3 - ) and nitrite (NO 2 - ) at the Hanford. The only calculation of nitrate release from a hypothetical grouted LAW inventory in the IDF showed that the overall release was slightly above the compliance limit of 45 mg/L nitrate and 3.32 mg/L nitrate after 1000 years (Asmussen et al. 2019). As such, uncertainty around the impact of nitrate and nitrite release from the IDF was identified in the recent National Academies of Sciences study of Hanford supplemental LAW by both the national laboratory team and Hanford stakeholders (Bates et al. 2023). However, these calculations (and others for the IDF involving secondary waste grout) may be conservative as no nitrate and nitrite retention in the grout waste form was assumed, nor any attenuation in the subsurface. There is evidence from the literature of processes that can attenuate nitrate migration both in the waste form and in the Hanford subsurface. If found to be technically defensible and likely to occur in the IDF and associated subsurface, then these processes should be included in modeling of the IDF to represent the behavior of nitrate and nitrite more accurately. Doing so would remove unnecessary conservatism in the modeling projections and reduce the uncertainty in assessments of facility compliance of a grouted LAW waste form in the IDF.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Vitrification of Hanford Tank 241-AP-105 Waste at 7 M Na and Equivalent Simulant

Hanford Site nuclear waste is to be vitrified at the Waste Treatment and Immobilization Plant (WTP), which is a part of the safe and efficient retrieval, treatment, and disposal mission of the U.S. Department of Energy Office of River Protection. Hanford tank 241-AP-105 (referred to herein as AP-105) is one of the initial Hanford radioactive tank wastes planned to be processed and vitrified. A portion of AP-105 waste was retrieved by Washington River Protection Solutions, LLC (WRPS) and transferred to Pacific Northwest National Laboratory (PNNL). The waste went through dilution by Columbia River water to reach a target sodium (Na) concentration of 7 M, solids filtration, and cesium removal by ion exchange. A glass composition was calculated from the Kim et al. glass models to satisfy the WTP baseline requirements based on the as-received sample and the target dilution to 7 M, from which a simulant was calculated and glass forming chemical (GFC) additions were determined to form a liquid/solids mixture called melter feed. To prepare for the processing of the 7 M Na AP-105 waste melter feed and learn about the production expectations, the melter feed simulant of 7 M Na AP-105 waste was processed in a non-radioactive, continuous laboratory-scale melter (CLSM) system.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Alternative reductants for foam control during vitrification of high-iron High Level Waste (HLW) feeds

Foaming during vitrification of radioactive waste in Joule-Heated Ceramic Melters (JHCM) is exacerbated by trapping of evolving gases, such as CO 2 , NO x and O 2 , beneath a viscous reaction layer. Foaming restricts heat transfer during melting. Sucrose is employed as the baseline additive at the Hanford site in Washington State, USA to reduce foaming. Alternative carbon-based reductant additives were explored in simulated, inactive Hanford high-iron HLW-NG-Fe2 feeds, for both their effect on foaming and to give insight to the behaviour of multivalent species in glass melts under different redox conditions. Graphite, coke (93% C), formic acid and HEDTA additives were compared with sucrose, and a feed with no additive. Graphite and coke additions proved most effective in reducing the maximum foam volume by 51 ± 3% and 54 ± 2%, respectively, compared with 24 ± 5% for sucrose. Lower foaming could result in more efficient vitrification in JHCMs. Reductants also affected redox ratios in the multivalent species present in the feed. The order of reduction, Mn 3+ /Mn 2+ > Cr 6+ /Cr 3+ > Ce 3+ /Ce 4+ > Fe 3+ /Fe 2+ was as predicted on the basis of their redox potentials. There is less reduction overall, particularly in the Fe 3+ → Fe 2+ , than predicted by the calculations, attributed to the oxygenated atmosphere of the experiments.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Vitrification of Hanford Tank 241-AP-101 Waste and Simulant

Hanford tank 241-AP-101 (referred to herein as AP-101) is the second Hanford radioactive tank waste planned to be processed and vitrified. A simulant version of AP 101 waste was formulated from the best-basis inventory (BBI) for the Hanford Tank 241-AP-101 liquid with an assumed target dilution of the waste from the BBI sodium molarity of 8.61 M to the desired 5.5 M Na. After the addition of glass-forming chemicals (GFCs), the simulant melter feed was processed in a non-radioactive, continuous laboratory-scale melter (CLSM) system. The AP-101 simulant melter feed was charged into the CLSM for 6.11 h of processing, which produced 6.55 kg of glass, for an average glass production rate of 2275 kg m 2 d -1 . Since there were no processing issues with the AP-101 simulant melter feed, AP-101 melter feed made with actual waste was then processed in a CLSM system built into a contamination area in a radioactive environment. The melting behavior characteristics appeared similar for both the simulant and waste melter feeds. The AP-101 waste melter feed was charged into the CLSM for 12.14 h of processing, which produced 8.75 kg of glass, for an average glass production rate of 1530 kg m 2 d -1 . During the AP-101 waste melter feed charging, the pump used to move the feed reached a maximum and it is believed that if the pump had a greater capacity, a greater average glass production rate could have been achieved. A constituent of interest present in low quantities in the AP-101 waste is 99 Tc or its non-radioactive surrogate, Re, added to the AP-101 simulant. Analysis for the quantities of 99 Tc and Re in the AP-101 glass product resulted in an average single-pass retention from the melter feed during relative chemical steady state of 55 ± 2 % for 99 Tc and 45 ± 2 % for Re. Compared to the processing of other melter feeds, the retention of 99 Tc in the AP-101 glass was greater than in both AP-107 and AP-105 glass, while the retention of Re in the AP-101 was less than in the AP-107 glass, but greater than in the AP-105 glass. A spike of I was added into the AP-101 melter feed that could be detected above the analysis detection limits. However, the iodine was only detectable above the ~6 ppm limit in one glass pour: the pour immediately following the burn off of the cold cap, where the I level reached ~30 ppm. This event was significant because the glass was poured immediately after burn off and thus it is presumed that the iodine had yet to volatilize from the glass melt while idling. It is recommended to perform future tests with I spikes at greater levels so that it can be detected in additional glass pours to determine if the expected 50 % retention of I used in the Kim et al. glass models can be confirmed. Offgas liquid samples were analyzed for acetonitrile, which was present at greater concentrations in CLSM liquids than in other scaled melter systems. This result was expected based on unique conditions with the CLSM system including a small plenum space leading to low residence time for offgas and the rapidity of offgas cooling upon exiting the CLSM vessel due to the location and environment. About 90 % of the total acetonitrile captured during both the AP-101 simulant and waste CLSM runs was found in the offgas condensate and demister liquids, thus it is recommended that only those liquids be sent for analysis if future testing to study the presence of acetonitrile in offgas products is desired.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Effect of sucrose on technetium and rhenium retention during vitrification of low-activity wastes

Sucrose (C 12 H 22 O 11 ) has been used in low-activity waste (LAW) melter feeds containing large fractions of nitrates, nitrites, or both because it facilitates foam suppression and denitration. This study focused on the effect of sucrose in LAW feeds on technetium (Tc) and rhenium (Re) retention. The amount of sucrose added in feeds was varied to differentiate the carbon-to-nitrogen mole ratio (C/N ratio). The results show that larger sucrose addition (higher C/N ratio) enhances Tc and Re retention. Reducing conditions induced by sucrose decomposition and early chemical reactions between sucrose and NaNO 3 /NaNO 2 are expected to increase Tc and Re retention. However, high sucrose addition decreased sulfur (S) retention slightly because sodium sulfate decomposes in reducing conditions at lower temperature. This early sulfate decomposition can affect Tc and Re retention partly because these species can be soluble in sulfate phases. This correlation indicates that the decrease of sulfate phases in the glass by early decomposition can reduce the solubility of Tc and Re in the sulfate phases, which may increase Tc and Re retention in the glass. In addition, continuous gas evolution and vigorous foaming at the foaming temperature range of 700–900°C may influence Tc and Re retention process interrupting retention or facilitating volatilization.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Vitrification of Hanford Tank Wastes for Condensate Recycle and Feed Composition Changeover Testing (Rev. 1)

During the vitrification of Hanford Site nuclear waste at the Waste Treatment and Immobilization Plant (WTP), which is a part of the safe and efficient retrieval, treatment, and disposal mission of the U.S. Department of Energy Office of River Protection, the offgas condensate generated from the waste-to-glass conversion is currently planned to be concentrated by evaporation in the Effluent Management Facility (EMF). This concentrated condensate can then be recycled back to the incoming waste and vitrified. To test the recycle process, an apparatus was designed and built to mimic the EMF evaporator and was then used to concentrate a volume of condensate produced during the vitrification of a sample of Hanford tank 241-AP-107 (referred to herein as AP-107) waste in a continuous laboratory-scale melter (CLSM). The concentrated condensate was added to an additional sample of AP-107 waste, to mimic one round of the recycle process, and the combined solution was vitrified, producing a second round of recycle condensate. In the current study, the EMF test apparatus was used to concentrate the second-round recycle condensate under evaporation conditions (at 45 °C and 1.4 psia) designed to emulate EMF operation. The condensate was successfully concentrated by a factor of ~10 while retaining over 95 % of the technetium-99 (99Tc), Cs, and I inventories in the concentrate. Another portion of AP-107 waste was retrieved by Washington River Protection Solutions, LLC (WRPS) and transferred to Pacific Northwest National Laboratory (PNNL), where it was pretreated and then combined with the second-round recycle AP-107 condensate concentrate and glass-forming chemicals (GFCs) to form the two-time recycle AP-107 melter feed, approximating a second round to the recycling action to be performed at the WTP. A portion of AP-105 waste was also retrieved by WRPS and provided to PNNL for pretreatment and combining with GFCs to form AP-105 melter feed. The two-time recycle AP-107 and AP-105 melter feeds were processed consecutively in the CLSM. The CLSM run proceeded for 13.63 hours, producing 9.70 kg of glass for an average glass production rate of 1464 kg m 2 d -1 during the two-time recycle AP-107 feed charging and 1568 kg m 2 d -1 during the AP-105 feed charging. The rate during AP-107 charging was essentially equivalent to the rate when processing no-recycle AP-107 feed and lower than that achieved when processing one-time recycle AP-107 feed. However, all rates were within the potential range of variability when processing melter feeds with similar composition in the CLSM. Likewise, the rate during AP-105 charging was higher than the previous rate processing AP-105, but within the potential CLSM range. The cold-cap characteristics changed from the typically thin AP-107 cold cap to a foamy-edged cold cap as previously seen with AP-105 shortly after transitioning to the AP-105 melter feed. The glass produced during the CLSM run was within 10 % of its target composition for the primary glass components. The CaO and Li 2 O targets varied by more than 1 wt% between the two-time recycle AP-107 and AP-105 glass targets and it took about 2 turnovers of the CLSM glass inventory to reach a relative chemical steady state in the glass for CaO and Li 2 O after the melter feed inputs were switched.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Vitrification of Hanford Tank Wastes for Condensate Recycle and Feed Composition Changeover Testing

During the vitrification of Hanford Site nuclear waste at the Waste Treatment and Immobilization Plant (WTP), which is a part of the safe and efficient retrieval, treatment, and disposal mission of the U.S. Department of Energy Office of River Protection, the offgas condensate generated from the waste-to-glass conversion is currently planned to be concentrated by evaporation in the Effluent Management Facility (EMF). This concentrated condensate can then be recycled back to the incoming waste and vitrified. To test the recycle process, an apparatus was designed and built to mimic the EMF evaporator and was then used to concentrate a volume of condensate produced during the vitrification of a sample of Hanford tank 241-AP-107 (referred to herein as AP-107) waste in a continuous laboratory-scale melter (CLSM). The concentrated condensate was added to an additional sample of AP-107 waste, to mimic one round of the recycle process, and the combined solution was vitrified, producing a second round of recycle condensate. In the current study, the EMF test apparatus was used to concentrate the second-round recycle condensate under evaporation conditions (at 45 °C and 1.4 psia) designed to emulate EMF operation. The condensate was successfully concentrated by a factor of ~10 while retaining over 95 % of the technetium-99 ( 99 Tc), Cs, and I inventories in the concentrate. Another portion of AP-107 waste was retrieved by Washington River Protection Solutions, LLC (WRPS) and transferred to Pacific Northwest National Laboratory (PNNL), where it was pretreated and then combined with the second-round recycle AP-107 condensate concentrate and glass-forming chemicals (GFCs) to form the two-time recycle AP-107 melter feed, approximating a second round to the recycling action to be performed at the WTP. A portion of AP-105 waste was also retrieved by WRPS and provided to PNNL for pretreatment and combining with GFCs to form AP-105 melter feed. The two-time recycle AP-107 and AP-105 melter feeds were processed consecutively in the CLSM. The CLSM run proceeded for 13.63 hours, producing 9.70 kg of glass for an average glass production rate of 1464 kg m 2 d -1 during the two-time recycle AP-107 feed charging and 1568 kg m 2 d -1 during the AP-105 feed charging. The rate during AP-107 charging was essentially equivalent to the rate when processing no-recycle AP-107 feed and lower than that achieved when processing one-time recycle AP-107 feed. However, all rates were within the potential range of variability when processing melter feeds with similar composition in the CLSM. Likewise, the rate during AP-105 charging was higher than the previous rate processing AP-105, but within the potential CLSM range. The cold-cap characteristics changed from the typically thin AP-107 cold cap to a foamy-edged cold cap as previously seen with AP-105 shortly after transitioning to the AP-105 melter feed. The glass produced during the CLSM run was within 10 % of its target composition for the primary glass components. The CaO and Li 2 O targets varied by more than 1 wt% between the two-time recycle AP-107 and AP-105 glass targets and it took about 2 turnovers of the CLSM glass inventory to reach a relative chemical steady state in the glass for CaO and Li 2 O after the melter feed inputs were switched. The 99 Tc and total cesium content in the melter feeds were maintained at concentrations expected to be experienced at the WTP. During the CLSM run, while processing the two-time recycle AP-107 melter feed at a relative chemical steady state, the 99 Tc/Cs ratio was 10, and 34% of 99 Tc and 74% of Cs were retained in the glass. These values were higher than those measured in the CLSM run with one-time recycle AP-107 melter feed. After the transition to processing the AP-105 melter feed, when the production reached a relative chemical steady state, the 99 Tc/Cs ratio was 77 while 44% of 99 Tc was retained in the glass. The C's retention during this time frame reached 200% due to the excess C's in the glass after the target content decreased to 15% of its initial level in the two-time recycle AP-107 melter feed to the lower target in the Ap-105 melter feed. While iodine was below inductively coupled plasma mass spectrometry analytical reporting limits in the melter feed and glass samples, it was detected in quantities above the analytical reporting limits in the liquid and filter samples collected from the CLSM offgas treatment system. The behavior of iodine in the CLSM offgas treatment system followed a similar pattern to those of 99 Tc and Cs.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Melting rate correlation with batch properties and melter operating conditions during conversion of nuclear waste melter feeds to glasses

The rate of conversion of nuclear waste melter feed to glass is affected by the selection of melter feed materials and by melter design and operation. The melting rate correlation (MRC) is an equation that relates the glass production rate with two types of variables: (1) feed and melt properties: conversion heat, cold-cap bottom temperature, and glass melt viscosity; and (2) melter design and operation parameters: melter geometry, melter operating temperature, and gas bubbling rate. The MRC shows good agreement for an extended melting-rate data set of high-level waste (HLW) melter feeds and a data set generated for low-activity waste (LAW) melter feeds. Laboratory observation of heated melter feed samples is often used to assess the cold-cap bottom temperature of HLW melter feeds (moderately foaming feeds), but this technique appears inadequate for LAW melter feeds (vigorously foaming feeds). For LAW feeds, an adequate assessment of the cold-cap bottom temperature was achieved using evolved gas analysis, which allows identification of the collapse of primary foam for oxidized feeds. This assessment shows that the cold-cap bottom temperature for vigorously foaming LAW feeds is higher than that for moderately foaming HLW feeds. When the results of MRC are compared, LAW feeds are generally less sensitive to the bubbling rate and melt viscosity, and more sensitive to the cold-cap bottom temperature than HLW feeds. The MRC qualifies as a promising tool to support the selection of melter feed materials and melter operating conditions, which is determined from expensive independent scaled melter experiments, and sophisticated mathematical models.

Lee, Seung Min↗

Vitrification of Hanford Tank 241-AP-107 with Recycled Condensate

During the vitrification of nuclear waste at the Hanford Waste Treatment and Immobilization Plant (WTP) – the primary mission of the U.S. Department of Energy Office of River Protection – the offgas condensate generated from the waste-to-glass conversion is currently planned to be concentrated by evaporation in the Effluent Management Facility (EMF). This concentrated condensate can then be recycled back to the incoming waste and vitrified. To test the recycle process, a test apparatus was designed to mimic the EMF evaporator and used to concentrate a volume of condensate that had been previously produced during the vitrification of Hanford tank 241-AP-107 (referred to herein as AP-107) waste in a continuous laboratory-scale melter (CLSM). The test apparatus successfully concentrated the AP-107 condensate by a factor of 10 while retaining over 90 % of the technetium-99 ( 99 Tc), Cs, and I inventory. A second portion of AP-107 waste was retrieved by Washington River Protection Solutions, LLC, given to Pacific Northwest National Laboratory, and combined with the AP-107 condensate concentrate after undergoing solids filtration and cesium removal by ion exchange. This combination served to approximate the recycling action to be performed at the WTP. After the addition of glass-forming chemicals (GFCs), the combined AP-107 waste and AP-107 condensate concentrate were processed in the CLSM to produce a glass, called AP-107-1R, that was designed to satisfy the WTP baseline requirements (Kim et al. 2012). During the 8.87 hours of processing, 7.27 kg of AP-107-1R glass were produced for an average glass production rate of 1739 kg m 2 d -1 . Compared to the previous run in the CLSM without recycled condensate, the run with the recycle had a greater average glass production rate, but the rate was within the potential range of variability when processing melter feeds with similar composition in the CLSM. The glass produced from the AP-107 recycle run in the CLSM was within 10 % of the target AP-107-1R glass composition with respect to the primary glass components. Analysis of the minor component impurities revealed that their content in the glass product had approached their nominal target after 2 turnovers of the glass inventory in the CLSM while the activity of the minor radionuclides was retained in the glass product. The 99 Tc and total cesium content in the combined AP-107 waste and recycled condensate were maintained at concentrations expected to be experienced at the WTP. During processing in the CLSM, at discrete sampling time periods, the target 99 Tc/Cs mass ratio in the glass formulation varied from 0.9 to 62.9. Across this range, the Cs retention in the glass ranged from 53 to 60 %, while the retention from the entire runtime totaled 68 %, values which align with Cs retention in other scaled melter systems while processing LAW melter feeds at 99 Tc/Cs mass ratios ranging from 1 to 100. The 99 Tc retention in the glass ranged from 22 to 32 %, primarily due to the cold-cap coverage on the glass melt surface, the area covered by reacting melter feed, varying from ~80 % to ~95 % during processing, demonstrating greater volatility of 99 Tc from the glass while more surface was exposed, as expected based on previous 99 Tc volatility studies.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Vitrification of High-Cr Glass in Research-Scale Melter

This test report describes the experimental results from a small-scale test using the research-scale melter (RSM) at Pacific Northwest National Laboratory to demonstrate processing of a high-Cr simulated feed stream, designated HLW-HCr-16. The RSM is a small, joule-heated melter capable of processing melter feed continuously. The melter is equipped with Inconel ® 693 electrodes, Monofrax ® K-3 refractory, and an Inconel 690 pour spout. An electric kiln surrounds the melter body and minimizes heat loss from the melter body during operation. The RSM is equipped with an offgas treatment system that employs quenching, wet scrubbing, and high-efficiency mist elimination. The glass-discharge section is heated to facilitate pouring of the glass. The melter is fitted with a melt cavity that is ~25 cm (10 in.) in diameter with a nominal glass depth of 8.9 cm (3.5 in.). The melter was operated with a target glass temperature of 1150°C and target plenum temperature between 550°C and 700°C for this test. The air bubbling rate was 4.2 L/min. Overall, during the continuous operation of the melter for ~ 103 hours, ~ 141 kg of glass was produced. At the conclusion of the test, the melter and exhaust lines were visually inspected for particulate deposition and corrosion. Entrained material had adhered to the underside of the melter lid and to the exhaust piping. Enrichments in elements such as Cl, F, B, K, Li, P, Na, and S were measured in these deposits through inductively coupled plasma–optical emission spectroscopy and X-ray fluorescence analysis. When the melter electrodes and air bubbler tube were removed from the glass in the RSM, the electrodes appeared discolored, but no significant loss of metal was observed. The processing of a high-Cr simulant, HLW-HCr-16, in the RSM produced glass at an average rate of 1.36 kg/h, equaling a melter-surface-area normalized glass generation rate of 654 kg/day/m 2 . The resulting glass met the toxicity characteristic leaching procedure requirement. Test results of crystallinity, electrical conductivity, and viscosity showed good processing properties of this high-Cr high-level waste glass. RSM offgas was also sampled and analyzed at periodic intervals during steady-state operating conditions. The total decontamination factor averaged by four sampling periods was 134. The concentrations of CO and NO x in emissions were 237 to 422 and 69 to 94 parts per million by volume, respectively.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Laboratory-Scale Melter Systems for Simulated and Real AP-107 Tank Waste - 20483

The Hanford Waste Treatment and Immobilization Plant (WTP) will process and stabilize waste that is stored in underground tanks on the Hanford Site. At the WTP, the tank waste will be combined with glass-forming and modifying additives to form an aqueous and solid mixture called melter feed, which will then be vitrified in joule-heated melters. A small-scale melter system, the continuous laboratory-scale melter (CLSM), is designed to operate with a continuous feeding process while periodically pouring glass product and collecting off-gas. Two CLSMs were constructed: one in a non-radioactive environment for processing waste simulants and another in a fume hood capable of handling radioactive material for processing actual Hanford tank waste. The waste sample received for vitrification in the CLSM was from Hanford tank 241-AP-107. Approximately 12 liters of melter-feed slurry was vitrified into 7 kilograms of glass product over the course of 10 hours of charging to the CLSM. The partitioning of technetium-99 in the product streams was used to calculate the technetium-99 recovery and help determine when the vitrification process had reached a steady state. The average single-pass retention of technetium-99 in the glass product was then calculated for the processing of AP-107 waste in the CLSM system. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Continuous Laboratory-Scale Melter Runs for System Evaluation

The Waste Treatment and Immobilization Plant (WTP) will process and stabilize waste that is stored in underground tanks on the Hanford Site. Currently, the first phase of the planned WTP startup and operation, called Direct Feed Low-Activity Waste (DFLAW), involves directly feeding only the liquid portion of the waste to electric melters in the WTP Low-Activity Waste (LAW) Vitrification Facility without full pretreatment. A second portion of the tank waste, called high-level waste (HLW), is set to contain most of the radioactivity inventory.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗