Search NASA⌕ Search

Engineering topics

Doering, Dionisio

Publications and source records attributed to Doering, Dionisio.

GAMPix: a novel fine-grained, low-noise and ultra-low power pixelated charge readout for TPCs

Here, we report on the development of a novel pixel charge readout system, Grid Activated Multi-scale pixel readout (GAMPix), which is under development for use in the GammaTPC gamma ray instrument concept. GammaTPC is being developed to optimize the use of liquid argon time projection chamber technology for gamma ray astrophysics, for which a fine grained low power charge readout is essential. GAMPix uses a new architecture with coarse and fine scale instrumented electrodes to solve the twin problems of loss of measured charge after diffusion, and high readout power. Fundamentally, it enables low noise and ultra low power charge readout at the spatial scale limited by diffusion in a time projection chamber, and has other possibly applications, including future DUNE modules.

Shutt, Tom↗

slaclab/cryo-on-epix-hr-dev

This is the repository for "cryo-on-epix-hr-dev" developed by SLAC National Accelerator Laboratory.

Doering, Dionisio↗

Smart sensors using artificial intelligence for on-detector electronics and ASICs

Cutting edge detectors push sensing technology by further improving spatial and temporal resolution, increasing detector area and volume, and generally reducing backgrounds and noise. This has led to a explosion of more and more data being generated in next-generation experiments. Therefore, the need for near-sensor, at the data source, processing with more powerful algorithms is becoming increasingly important to more efficiently capture the right experimental data, reduce downstream system complexity, and enable faster and lower-power feedback loops. In this paper, we discuss the motivations and potential applications for on-detector AI. Furthermore, the unique requirements of particle physics can uniquely drive the development of novel AI hardware and design tools. We describe existing modern work for particle physics in this area. Finally, we outline a number of areas of opportunity where we can advance machine learning techniques, codesign workflows, and future microelectronics technologies which will accelerate design, performance, and implementations for next generation experiments.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

slaclab/epix-quad

This is the repository for "slaclab/epix-quad" developed by SLAC National Accelerator Laboratory.

Kwiatkowski, Maciej↗

slaclab/epix-hr-single-10k

This is the repository for "epix-hr-single-10k" developed by SLAC National Accelerator Laboratory.

Doering, Dionisio↗

slaclab/lcls2-epix-hr-pcie

This is the repository for "slaclab/lcls2-epix-hr-pcie" developed by SLAC National Accelerator Laboratory.

Ruckman, Larry↗

slaclab/cryo-wib-firmware

This is the repository for "cryo-wib-firmware" developed by SLAC National Accelerator Laboratory.

Doering, Dionisio↗

slaclab/epix-hr-core

This is the repository for "slaclab/epix-hr-core" developed by SLAC National Accelerator Laboratory.

Ruckman, Larry↗

slaclab/epix

This is the repository for "slaclab/epix" developed by SLAC National Accelerator Laboratory.

Kwiatkowski, Maciej↗

The ePix10k 2-megapixel hard X-ray detector at LCLS

The ePix10ka2M (ePix10k) is a new large area detector specifically developed for X-ray free-electron laser (XFEL) applications. The hybrid pixel detector was developed at SLAC to provide a hard X-ray area detector with a high dynamic range, running at the 120 Hz repetition rate of the Linac Coherent Light Source (LCLS). The ePix10k consists of 16 modules, each with 352 × 384 pixels of 100 µm × 100 µm distributed on four ASICs, resulting in a 2.16 megapixel detector, with a 16.5 cm × 16.5 cm active area and ∼80% coverage. The high dynamic range is achieved with three distinct gain settings (low, medium, high) as well as two auto-ranging modes (high-to-low and medium-to-low). Here the three fixed gain modes are evaluated. The resulting dynamic range (from single photon counting to 10000 photons pixel −1 pulse −1 at 8 keV) makes it suitable for a large number of different XFEL experiments. The ePix10k replaces the large CSPAD in operation since 2011. The dimensions of the two detectors are similar, making the upgrade from CSPAD to ePix10k straightforward for most setups, with the ePix10k improving on experimental performance. The SLAC-developed ePix cameras all utilize a similar platform, are tailored to target different experimental conditions and are designed to provide an upgrade path for future high-repetition-rate XFELs. Here the first measurements on this new ePix10k detector are presented and the performance under typical XFEL conditions evaluated during an LCLS X-ray diffuse scattering experiment measuring the 9.5 keV X-ray photons scattered from a thin liquid jet.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗