Benchmarking the AirSquared All-Metal Scroll Pump Against the Normetex 15 - Preliminary report

Tritium operations require specialized equipment for material compatibility, safety, and waste considerations. Non-metallic pump materials (polymer, oil, or grease) on a tritium-wetted surface can absorb tritium and/or undergo isotope exchange between tritium and more common protium, creating tritiated compounds that can result in material property modification via beta-radiolysis, inventory loss, reduced performance and special waste considerations, all of which increase the operating cost for a facility. Vacuum pumps move gas via a pressure differential between volumes of an operation. Several types of all-metal vacuum pumps exist for this application including metal bellows, diaphragm and scroll pumps. A metal bellows pump incorporates only metal components at the wetted surfaces. The common metal bellows pump employed in tritium facilities, the MB601 (Senior Metal Bellows, Sharon, PA, USA) creates a gas-motive force with a vacuum pressure between 30-40 torr. These pumps can efficiently move gas from one process step to another, as long as sub-30 torr pressures are not required. However, for higher vacuum demand, an all-metal scroll pump can be used with the bellows pump serving as a “backing” pump. This configuration typically provides an achievable vacuum of less than 20 mTorr. All-metal scroll pumps are a technology uniquely applicable to tritium gas handling. The industry standard all-metal scroll pump for glovebox-scale tritium operations is the Normetex 15 m 3 /hr, typically referred to as the Normetex 15 (Normetex Pompes, Pont Audemer, France). However, the final Normetex pumps were manufactured in 2012, rendering them no longer available. Eumeca SaRL (formerly Normetex) has developed and is marketing a scroll pump based on the design of the Normetex 15. A US company, AirSquared (Broomfield, Colorado), has developed and is marketing a potential alternative to the Normetex 15. The Gas Transfer Systems group (Q-7) of the Los Alamos National Laboratory (LANL) procured serial number 0001 of the AirSquared All Metal Vacuum Scroll pump model number V16H034A-C01 in 2019. The LANL Hydrogen Processing Laboratory (HPL) has been evaluating the performance of the pump compared to a Normetex pump as a potential replacement in tritium and fusion facilities requiring this type of pump.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Production Facility Prototype Blower 1000 Hour Test Results V

Long duration operations tests of the Aerzen GM 12.4 roots style blower in a closed loop configuration provides valuable data and lessons learned for long-term operation at the Mo-99 production facility. The blower was operated in a closed loop configuration with the flow conditions anticipated in plant operation with a Mo-100 target inline. The additional thermal energy generated from beam heating of the Mo-100 disks was not included in these tests. Thirteen long duration 500 to 1000 hour tests have been completed since the first test was performed in January of 2016. All thirteen long duration tests have proven successful in exposing preventable issues related to oil and helium leaks. All blower tests to this date have resulted in stable blower performance and consistency. A summary of the results for the end of the thirteenth test is included in this report. Complete details for the previous tests are shown in the reports, Production Facility Prototype Blower 1000 Hour Test Results, II, III, and IV.

36 MATERIALS SCIENCE↗

Uranium Bed Design Parameters for Tritium Plants Supporting Fusion Reactors

Uranium hydride is commonly used to store hydrogen or its isotopes in a solid state. The Self-Assaying Tritium Accountancy and Containment Unit for ITER (STACI) is a 5.2-kg bed of depleted uranium (dU) capable of holding up to 33 mol of hydrogen or its isotopes. Here we summarize the data analysis of past experimental campaigns with STACI, with the aim of describing the kinetics and thermodynamics of the hydriding process. Computed tomography imaging was performed on STACI both before and after its experimental campaign, and a high degree of swelling was observed in the dU. Literature on studies in regard to the swelling of large (multikilogram) quantities of uranium hydride for storage applications was not identified during this study. Data from the experimental campaign, as well as data on the formation reaction, are presented. The authors hope to create an analytical model of STACI based on these data.