Search NASA⌕ Search

Engineering topics

Dong, Qihuan

Publications and source records attributed to Dong, Qihuan.

Mitigating commutation failures in HVDC systems with SFCL deployment

Commutation failures represent a prevalent issue encountered in line-commutated-converter high voltage direct current (LCC-HVDC) systems. As the widespread deployment of HVDC systems continues, the risk associated with commutation failures increases, posing a growing threat to power grids due to their potential to trigger severe consequences, including cascading failures and widespread blackouts. This research paper aims to address the significant issue of commutation failure within direct current (DC) systems through advocating for the use of resistive-type Superconducting Fault Current Limiters (R-SFCLs). To substantiate the efficacy of this proposed strategy, an array of simulations are executed using the PSCAD/EMTDC software. This comprehensive study investigates the performance characteristics of R-SFCLs configured with varying resistance values, scrutinizing their response under diverse fault resistance scenarios and distinct fault initiation times within the LCC-HVDC system. The outcomes of these simulations are that SFCLs confer significant advantages for mitigating commutation failures, surpassing traditional mitigation methods in terms of effectiveness. Consequently, SFCLs emerge as an optimal solution to prevent commutation failures in the HVDC systems.

Commutation failure↗

Quasi-Static Time Series Fatigue Simulation for PV Inverter Semiconductors with Long-Term Solar Profile

Power system simulations with long-term data tend to have large time steps varying from one second to a few minutes. However, for PV inverter semiconductors, the minimum thermal stresses cycle is with line frequency. This requires the time step of the fatigue simulation to be much smaller than the line period. This small time step results in poor simulation speed, especially for long-term simulations. This paper proposes a fast fatigue simulation for inverter semiconductors using the quasi-static time series (QSTS) simulation concept. The fatigue analysis typically focuses on the peak and valley values of a strain and neglect the transients from peaks to valleys. The proposed simulation utilizes this property of fatigue analysis and calculates the steady state of the semiconductor junction temperature only. The resulting time step of the fatigue simulation is 15 minutes, which is consistent with the solar dataset without losing accuracy.

fast simulation↗

GMLC 1.5.03: Increasing Distribution System Resiliency using Flexible DER and Microgrid Assets Enabled by OpenFMB (Duke-RDS Final Report)

This is the final project report for the Grid Modernization Laboratory Consortium (GMLC) Resilient Distribution System (RDS) project titled “Increasing Distribution System Resiliency using Flexible DER and Microgrid Assets Enabled by OpenFMB”. The primary goal of this project was to increase the resiliency of distribution systems at utilities around the nation by deploying flexible operating strategies that engage end-use assets as a resource.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Integrating Transactive Energy into Reliability Evaluation for a Self-healing Distribution System with Microgrid

Non-utility owned distributed energy resources (DERs) are mostly untapped currently, but they can provide many grid services such as voltage regulation and service restoration, if properly controlled, and can improve the distribution systems reliability when coordinated with utility-owned assets such as self-healing control and microgrids. This paper integrates transactive energy control into the distribution system reliability evaluation to quantitatively assess the impact of non-utility owned DERs on reliability improvement. Here, a transactive reactive power control strategy is designed to incentivize the DERs to provide reactive power support for improving voltage profiles thus enabling additional customer load restoration during an outage. Also, an operational sequence to coordinate the non-utility owned DERs with the utility owned self-healing control and utility owned microgrids is designed and integrated into the service restoration process with the operational constraints guaranteed by checking the three-phase unbalanced power flow for post-fault network reconfiguration. The reliability indices are then calculated through a Monte Carlo simulation. The transactive reactive power control strategy is tested on a four-feeder distribution system operated by Duke Energy in the U.S. Results demonstrate that the non-utility owned DERs with the transactive control improve the reliability of both the system and critical loads by more than 30%.

24 POWER TRANSMISSION AND DISTRIBUTION↗