Search NASA⌕ Search

Engineering topics

Donohue, James M.

Publications and source records attributed to Donohue, James M..

Dual-Mode Scramjet Flameholding Operability Measurements

Flameholding measurements were made in two different direct connect combustor facilities that were designed to simulate a cavity flameholder in the flowfield of a hydrocarbon fueled dual-mode scramjet combustor. The presence of a shocktrain upstream of the flameholder has a significant impact on the inlet flow to the combustor and on the flameholding limits. A throttle was installed in the downstream end of the test rigs to provide the needed back-pressurization and decouple the operation of the flameholder from the backpressure formed by heat release and thermal choking, as in a flight engine. Measurements were made primarily with ethylene fuel but a limited number of tests were also performed with heated gaseous JP-7 fuel injection. The flameholding limits were measured by ramping inlet air temperature down until blowout was observed. The tests performed in the United Technologies Research Center (UTRC) facility used a hydrogen fueled vitiated air heater, Mach 2.2 and 3.3 inlet nozzles, a scramjet combustor rig with a 1.666 by 6 inch inlet and a 0.65 inch deep cavity. Mean blowout temperature measured at the baseline condition with ethylene fuel, the Mach 2.2 inlet and a cavity pressure of 21 psia was 1502 oR. Flameholding sensitivity to a variety of parameters was assessed. Blowout temperature was found to be most sensitive to fuel injection location and fuel flowrates and surprisingly insensitive to operating pressure (by varying both back-pressurization and inlet flowrate) and inlet Mach number. Video imaging through both the bottom and side wall windows was collected simultaneously and showed that the flame structure was quite unsteady with significant lateral movements as well as movement upstream of the flameholder. Experiments in the University of Virginia (UVa) test facility used a Mach 2 inlet nozzle with a 1 inch by 1.5 inch exit cross section, an aspect ratio of 1.5 versus 3.6 in the UTRC facility. The UVa facility tests were designed to measure the sensitivity of flameholding limits to inlet air vitiation by using electrically heated air and adding steam at levels to simulate vitiated air heaters. The measurements showed no significant difference in blowout temperature with inlet air mole fractions of steam from 0 to 6.7%.

airbreathing engines aircraft↗

Experimental and numerical study of swept ramp injection into a supersonic flowfield

Time-averaged measurements of pressure, temperature, velocity, and injectant mole fraction are presented using the planar laser-induced iodine fluorescence technique in the complex three-dimensional compressible flowfield around a swept ramp fuel injector. Within the range of thermodynamic conditions present in the test case studied, the technique's accuracy is estimated to be 4% for pressure, temperature, and velocity and 3% for injectant mole fraction. Comparisons with numerical simulations using the SPARK three-dimensional Navier-Stokes computer code with an algebraic turbulence model are made at the centerplane of the flowfield as well as on three crossflow planes downstream of the injector. Calculations and measurements are in good agreement throughout the flowfield, with deviations on the order of 5%; however, in specific regions, such as in the base of the ramp, deviations are larger. A weak asymmetry in the incoming flowfield appears to be amplified by boundary-layer separation occurring when the ramp-generated shock reflects off the tunnel walls. Ramp-generated vortices are weaker in the calculated results due to the effects of numerical viscosity in the vortex cores. This leads to less turning and mixing of the jet plume than observed in the experiments. The rate of decay of the maximum injectant mole fraction with streamwise distance is greater for the present ramp injection scheme than for previously measured transverse injection schemes. In this recirculation region at the base of the injector, laminar calculations show better agreement with the measurements than turbulent calculations.

Donohue, James M.↗

Experimental and numerical study of swept ramp injection into a supersonic flowfield

Time-averaged measurements of pressure, temperature, velocity, and injectant mole fraction are presented using the planar laser-induced iodine fluorescence (PLIIF) techniques in the complex 3D compressible flowfield around a swept ramp fuel injector. Within the range of thermodynamic conditions present in the test case studied, the technique's accuracy is estimated to be 4 percent for pressure, 4 percent for temperature, 4 percent for velocity, and 3 percent for injectant mole fraction. Comparisons to numerical simulations using the SPARK 3D Navier-Stokes computer code with an algebraic turbulence model are made at the centerplane of the flowfield as well as on three crossflow planes downstream of the injector, and good agreement is found. A weak asymmetry in the incoming flowfield appears to be amplified by boundary layer separation occuring when the the ramp generated shock reflects off the tunnel walls. In the near field of the injector, laminar calculations show better agreement to the measurements than turbulent calculations.

Donohue, James M.↗

Computer-controlled multi-parameter mapping of 3D compressible flowfields using planar laser-induced iodine fluorescence

A computer-controlled technique, using planar laser-induced iodine fluorescence, for measuring complex compressible flowfields is presented. A new laser permits the use of a planar two-line temperature technique so that all parameters can be measured with the laser operated narrowband. Pressure and temperature measurements in a step flowfield show agreement within 10 percent of a CFD model except in regions close to walls. Deviation of near wall temperature measurements from the model was decreased from 21 percent to 12 percent compared to broadband planar temperature measurements. Computer-control of the experiment has been implemented, except for the frequency tuning of the laser. Image data storage and processing has been improved by integrating a workstation into the experimental setup reducing the data reduction time by a factor of 50.

Donohue, James M.↗

Vorticity generation mechanisms in parallel injection schemes for supersonic mixing

A numerical study is reported of the three-dimensional nonreacting supersonic flow field produced by three parallel fuel injection schemes. Such injections are being considered as a means of enhancing fuel mixing in future Scramjet engine designs. The strength of vortex structures produced by ramp injectors and by rocket/jet interactions are quantified and their relative effectiveness in enhancing the fuel mixing process is addressed. An experimental setup for validation of the above numerical results has been constructed and preliminary results are presented. For the flow field parameters chosen, the ramp generated vorticity is found to be considerably larger than that generated by the shock. The unsteady recirculating flow field in the wake of the injector appears also to give rise to important additional vorticity and mixing.

Donohue, James M.↗