Search NASA⌕ Search

Engineering topics

Douglas, Matthew

Publications and source records attributed to Douglas, Matthew.

36 records · Page 2

ELECTROCHEMICALLY-MODULATED SEPARATIONS FOR DESTRUCTIVE AND NONDESTRUCTIVE ANALYSIS FOR PROCESS MONITORING AND SAFEGUARDS MEASURMENTS

A timely, accurate, and precise analysis of uranium reprocessing streams is import for process monitoring and nuclear material accountability. For material accountancy, it is critical to detect both acute and chronic diversions of nuclear materials. Therefore, both on-line nondestructive (NDA) and destructive analysis (DA) approaches are desirable. Current methods for DA involve grab sampling and laboratory based column extractions that are costly, hazardous, and time consuming. Direct on-line gamma measurements of Pu, while desirable, are not possible due to contributions from other actinides and fission products. Electrochemically-modulated separation (EMS) is a straightforward, cost effective alternative technology being investigated at Pacific Northwest National Laboratory for highly selective, slip-stream sampling of U or Pu from reprocessing streams. The EMS selectivity results from simultaneous surface and redox chemistry that allows the affinity of the electrode to be turned “on” or “off” under potential control. Once isolated, the accumulated Pu can be measured by gamma spectroscopy or retained in a small quantity (nanogram-milligram) to reduce radiological concerns and to facilitate transport to laboratory based mass spectrometry instrumentation. In this study, we investigate both destructive and nondestructive applications of EMS. First, nondestructive Pu gamma analysis is performed using dissolved BWR spent fuel. Reduction factors for actinide and fission products and initial estimates of measurement uncertainties were measured. The methodology for DA sampling will also be reported for both Pu and U.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

THE MULTI-ISOTOPE PROCESS (MIP) MONITOR: A NEAR-REAL-TIME, NON-DESTRUCTIVE, INDICATOR OF SPENT NUCLEAR FUEL REPROCESSING CONDITIONS

Researchers from Pacific Northwest National Laboratory and The Ohio State University are working to develop a system for monitoring spent nuclear fuel reprocessing facilities on-line, non-destructively, and in near-real-time. This method, known as the Multi-Isotope Process (MIP) Monitor, is based upon the measurement of distribution patterns of a suite of indicator (radioactive) isotopes present within product and waste streams of a nuclear reprocessing facility. Signatures from these indicator isotopes are monitored on-line by gamma spectrometry and compared, in near-real-time, to patterns representing "normal" process conditions using multivariate pattern recognition software. By targeting gamma-emitting indicator isotopes, the MIP Monitor approach is compatible with the use of small, portable, high-resolution gamma detectors that may be easily deployed throughout an existing facility. In addition, utilization of a suite of radio-elements, including ones with multiple oxidation states, increases the likelihood that attempts to divert material via process manipulation would be detected. Proof-of-principle modeling exercises simulating changes in acid strength have been completed and the results are promising. Laboratory validation is currently under way and significant results are available. The latest experimental results, along with an overview of the method will be presented.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Collection of fission and activation product elements from fresh and ocean waters: a comparison of traditional and novel sorbents

Monitoring natural waters for the inadvertent release of radioactive fission products produced as a result of nuclear power generation downstream from these facilities is essential for maintaining water quality. To this end, we evaluated sorbents for simultaneous in-situ large volume extraction of radionuclides with both soft (e.g., Ag) and hard metal (e.g., Co, Zr, Nb, Ba, and Cs) or anionic (e.g., Ru, Te, Sb) character. In this study, we evaluated a number of conventional and novel nanoporous sorbents in both fresh and salt waters. In most cases, the nanoporous sorbents demonstrated enhanced retention of analytes. Salinity had significant effects upon sorbent performance and was most significant for hard cations, specifically Cs and Ba. The presence of natural organic matter had little effect on the ability of chemisorbents to extract target elements.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Verifying the Presence of Low Levels of Neptunium in a Uranium Matrix with Electron Energy-Loss Spectroscopy

This paper examines the problems associated with the analysis of low levels of neptunium (Np) in a uranium (U) matrix with electron energy-loss spectroscopy (EELS) on the transmission electron microscope (TEM). The detection of Np in a matrix of uranium (U) can be impeded by the occurrence of a plural scattering event from U (U-M5 + U-O4,5) that results in severe overlap on the Np-M5 edge at 3665 eV. Low levels (1600 - 6300 ppm) of Np can be detected in U solids by confirming the energy gap between the Np-M5 and Np-M4 edges is at 184 eV and showing that the M4/M5 ratio for the Np is smaller than that for U. The Richardson-Lucy deconvolution method was applied to energy-loss spectral images and was shown to increase the signal to noise. This method also improves the limits of detection for Np in a U matrix.

38 RADIATION CHEMISTRY, RADIOCHEMISTRY, AND NUCLEA↗

Medium-resolution Autonomous in situ Gamma Detection System for Marine and Coastal Waters

We are developing a medium-resolution autonomous in situ gamma detection system for marine and coastal waters. The system is designed to extract and preconcentrate isotopes of interest from natural waters prior to detection in order to eliminate signal attenuation of the gamma rays traveling through water and lower the overall background due to the presence of naturally occurring radioactive isotopes (40K and U/Th series radionuclides). Filtration is used to preconcentrate target isotopes residing on suspended particles, while chemosorption is employed to preferentially extract truly dissolved components from the water column. A variety of commercial and in-house nano-porus chemosorbents have been selected, procured or produced, and tested. Used filter and chemosorbent media are counted autonomously using two LaBr3 detectors in a near 4-pi configuration around the samples. A compact digital pulse processing system developed in-house and capable of running in coincidence mode is used to process the signal from the detectors to a small on-board computer. The entire system is extremely compact (9” dia. x 30” len.) and platform independent, but designed for initial deployment on a research buoy.

Gamma ray spectrometry↗

FY 2009 Progress: Process Monitoring Technology Demonstration at PNNL

Pacific Northwest National Laboratory (PNNL) is developing and demonstrating three technologies designed to assist in the monitoring of reprocessing facilities in near-real time. These technologies include 1) a multi-isotope process monitor (MIP), 2) a spectroscopy-based monitor that uses UV-Vis-NIR (ultraviolet-visible-near infrared) and Raman spectrometers, and 3) an electrochemically modulated separations approach (EMS). The MIP monitor uses gamma spectroscopy and pattern recognition software to identify off-normal conditions in process streams. The UV-Vis-NIR and Raman spectroscopic monitoring continuously measures chemical compositions of the process streams including actinide metal ions (uranium, plutonium, neptunium), selected fission products, and major cold flow sheet chemicals. The EMS approach provides an on-line means for separating and concentrating elements of interest out of complex matrices prior to detection via nondestructive assay by gamma spectroscopy or destructive analysis with mass spectrometry. A general overview of the technologies and ongoing demonstration results are described in this report.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Dissolution of Uranium Oxides Under Alkaline Oxidizing Conditions

Bench scale experiments were conducted to determine the dissolution characteristics of uranium oxide powders (UO2, U3O8, and UO3) in aqueous peroxide-carbonate solutions. Experimental parameters included H2O2 concentration, carbonate counter cation (NH4+, Na+, K+, and Rb+), and pH. Results indicate the dissolution rate of UO2 in 1 M (NH4)2CO3 increases linearly with peroxide concentration ranging from 0.05 – 2 M. The three uranium oxide powders exhibited different dissolution patterns however, UO3 exhibited prompt complete dissolution. Carbonate counter cation affected the dissolution kinetics. There is minimal impact of solution pH, over the range 8.8 to 10.6, on initial dissolution rate.

Smith, Steven C↗

Separation and Quantification of Chemically Diverse Analytes in Neutron Irradiated Fissile Materials

Quantitative measurement of fission and activation products resulting from neutron irradiation of fissile materials is of interest for applications in environmental monitoring, nuclear waste management, and national security. To overcome mass and spectral interferences, and the relative small quantities of some target analytes, an extensive series of chemical separations is necessary. Based on established separations processes involving co-precipitation, solvent extraction, and ion-exchange and extraction chromatography, we have been evaluating and optimizing a proposed sequence of separation steps to allow for the timely quantification of analytes of interest. For simplicity, much of the chemical separation development work has been performed using stable elements as surrogates for the radioactive material. We have recently evaluated the optimized procedures using an irradiated sample to examine the adequacy of separations for measurement of desired analytes by gamma spectrometry. Here we present the results of this evaluation and describe the radiochemical separations utilized.

fission products↗

Dissolution of Uranium(IV) Oxide in Solutions of Ammonium Carbonate and Hydrogen Peroxide

Understanding the dissolution characteristics of uranium oxides is of fundamental scientific interest. Bench scale experiments were conducted to determine the optimal dissolution parameters of uranium(IV) oxide (UO2) powder in solutions of ammonium carbonate [(NH4)2CO3] and hydrogen peroxide (H2O2). Experimental parameters included variable peroxide and carbonate concentrations, and temperature. Results indicate the dissolution rate of UO2 in 1 M (NH4)2CO3 increases linearly with peroxide concentration ranging from 0.05 – 2 M (1:1 to 40:1 mol ratio H2O2:U), with no apparent maximum rate reached under the limited conditions used in our study. Temperature ranging studies show the dissolution rate of UO2 in 1 M (NH4)2CO3 and 0.1 M H2O2 (2:1 mol ratio H2O2:U) increases linearly from 15 °C to 60 °C, again with no apparent maximum rate reached. Dissolution of UO2 in solutions with constant [H2O2] and [(NH4)2CO3] ranging from 0.5 to 2 M showed no difference in rate; however dissolution was significantly reduced in 0.05 M (NH4)2CO3 solution. The results of this study demonstrate the influence of [H2O2], [(NH4)2CO3], and temperature on the dissolution of UO2 in peroxide-containing (NH4)2CO3 solutions. Future studies are planned to elucidate the solution and solid state complexes in these systems.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Ultra-Low Level Plutonium Isotopes in the NIST SRM 4355A (Peruvian Soil-1)

For more than 20 years, countries and their agencies which monitor discharge sites and storage facilities have relied on the National Institute of Standards and Technology (NIST) Standard Reference Material (SRM) 4355 Peruvian Soil reference material. Its low fallout contamination makes it an ideal soil blank for measurements associated with terrestrial pathway to man studies. Presently, SRM 4355 is out of stock, and a new batch of the Peruvian soil is currently under development as future NIST SRM 4355A. Both environmental radioanalytical laboratories and mass spectrometry communities will benefit from this SRM. The former must assess their laboratory contamination and measurement detection limits by measurement of blank sample material. The Peruvian Soil is so low in anthropogenic radionuclides that it is a suitable virtual blank. On the other hand, mass spectrometric laboratories have high sensitivity instruments that are capable of quantitative isotopic measurements at low plutonium levels of the SRM 4355 (first Peruvian Soil SRM) that provided the mass spectrometric community with the calibration, quality control, and testing material needed for methods development, and legal defensibility. The quantification of the ultra-low plutonium content in the SRM 4355A was a considerable challenge for the mass spectrometric laboratories. Careful blank control and correction, isobaric interferences, instrument stability, peak assessment, and detection assessment were necessary. Furthermore, a systematic statistical evaluation of the measurement results and considerable discussions with the mass spectroscopy metrologists were needed to derive the certified values and uncertainties. SRM 4355A will provide the mass spectrometric community with the quality control and testing material needed for higher sensitivity methods development, and legal defensibility.

Inn, Kenneth G↗

Uranium Extraction From Laboratory Synthesized, Uranium-Doped Hydrous Ferric Oxides

The extractability of uranium (U) from synthetic hydrous ferric oxides has been shown to decrease as a function of mineral ripening, consistent with the hypothesis that the ripening process decrease contaminant lability. To evaluate this process, three hydrous ferric oxide (HFO) suspensions were co-precipitated with uranyl (UO22+) and maintained at pH 7.0 ± 0.1. Uranyl was added to the HFO post-precipitation in a fourth suspension. Two suspensions also contained either co-precipitated silicate (Si-U-HFO) or phosphate (P-U-HFO). After precipitation of the HFOs, at time intervals of one week, one month, six months, one year, and 2 years, aliquots of the suspensions were contacted with five solutions for a range of time. The extracts were analyzed for U and iron (Fe). The results are consistent with the hypothesis that U and Fe extractability will decrease as the mineral phase ripens. All extracting solutions exhibited some degree of selectivity for U, as the proportional extraction of U exceeded that for congruent dissolution. Micro X-ray diffraction analysis indicates the transformation from an amorphous phase to a material containing substantial proportions of crystalline goethite and hematite, except the P-U-HFO which remained primarily amorphous. Further analysis of the co-precipitates by the Mössbauer technique and scanning electron microscopy (SEM) provides further evidence of mineralogic ripening

38 RADIATION CHEMISTRY, RADIOCHEMISTRY, AND NUCLEA↗

Nuclear Archeology in a Bottle: Evidence of Pre-Trinity U.S. Weapons Activities from a Waste Burial Site

During World War II, the Hanford Site in Washington was chosen for plutonium production. In 2004, a bottle containing a sample of plutonium was recovered from a Hanford waste trench. Isotopic age dating indicated the sample was separated from the fuel pellet 64 ±2.8 years earlier. Detectable products of secondary nuclear reactions, such as 22Na, proved useful as 1) a detectable analog for alpha emitting actinides, 2) an indicator of sample splitting, and 3) a measure of the time since sample splitting. The sample origin was identified as the X-10 reactor, Oak Ridge, TN. Corroborated by historical documents, we concluded this sample was part of the first batch of Pu separated at T-Plant, Hanford, the world’s first industrial-scale reprocessing facility, on December 9, 1944.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Electrochemically-Modulated Separation and Mass Spectrometric Analysis of Actinides in Difficult Matrices

Electrochemically-modulated separations (EMS) are a straightforward means of isolating and pre-concentrating elements for on-line mass spectrometric analysis. Elements are accumulated at electrochemical working electrodes and subsequently released into a clean carrier solution for spectroscopic analysis. EMS can employ solely aqueous chemistry and uses electrochemical redox adjustment of oxidation state to “trigger” reversible chelation / complexation. Less tractable elements (e.g., uranium and plutonium), based on redox potentials, can therefore be extracted from difficult matrices following redox adjustment and chelation with electrode chelation sites. Simply put, separation is achieved by a small voltage step that is applied to the target electrode to turn “on” or “off” the specific actinide affinity of an electrode. This separation technology employs both redox and chelation chemistry to effect highly selective accumulation of target actinides, and results in element separation, matrix elimination and analyte preconcentration. Prior studies have developed protocols and preliminary insight into EMS processes for U and Pu. U and Pu are released upon oxidation and reduction, respectively, allowing complete separation due to widely divergent redox potentials. T The coupling of EMS on-line with ICP-MS for elemental and isotopic analysis of uranium and plutonium is presented, with a focus on analytical performance metrics and applicability to safeguards and process monitoring via nondestructive analyses.

98 NUCLEAR DISARMAMENT, SAFEGUARDS, AND PHYSICAL P↗

Advanced Safeguards Technology Demonstration at Pacific Northwest National Laboratory

The IAEA has established international safeguards standards for fissionable materials at spent fuel reprocessing plants to ensure that significant quantities of weapons-grade nuclear material are not diverted over a specified time frame. It is, therefore, necessary to confirm proper operational performance to verify facilities operate under adequate safeguard-declared conditions. This verification can be achieved by employing monitoring equipment. Online real time monitoring of the flowsheet radiochemical streams provides a unique capability to rapidly identify deviations from normal operating conditions. Flowsheet monitoring technologies being developed at PNNL include three integrated systems: Multi-Isotope Process (MIP) Monitor, spectroscopy-based monitor (UV-vis-NIR and Raman spectrometers), and Electrochemically Modulated Separations (EMS). The MIP Monitor is designed to identify off-normal conditions in process streams using gamma spectroscopy and pattern recognition software. The spectroscopic monitoring continuously measures chemical compositions of the process streams including actinide metal ions (U, Pu, Np), selected fission products, and major cold flowsheet chemicals. EMS provides an on-line means for pre-separating and pre-concentrating elements of interest out of complex matrices prior to detection. PNNL is preparing to test these multi-parametric technologies using different samples of dissolved spent fuel and aqueous and organic phases of the PUREX and UREX flowsheets. We will report our on-going efforts with specific focus given to quantifying sensitivity of the MIP Monitor and UV-Vis and Raman spectrometers to detect minor changes in major process variables.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Design and Construction of A Cerenkov Counter for In Situ Monitoring of Sr-90 in Groundwater

Migration of groundwater contamination from beneath the U.S. Department of Energy’s Hanford Site into the Columbia River creates a need for in situ 90Sr monitoring. The prototype monitor discussed here is designed for deployment inside a monitoring well and provides near-real-time determination of the 90Sr concentration in a two-liter groundwater sample. The measurement is made by direct detection of Cerenkov light generated in the water by beta decay of the 90Y daughter. This manuscript presents results from a prototype monitor that was designed by a parametric Monte Carlo simulation study. Calibration and testing results of the as-built system show near perfect agreement between simulated predictions and experimental results. Downwell and laboratory tests demonstrate that the prototype monitor is sensitive to 90Sr at concentrations below drinking water standards of 8 pCi/l (0.3 Bq/l) at the 90% confidence level in measurement times of less than four hours.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Modeling of Gamma-ray Spectra to Direct Efficient Chemical Separations

In an age of heightened national security regarding nuclear terrorist threats, reliable and rapid analytical methods for the quantification of radionuclides in fission product samples are needed to provide forensic information and sample characterization. Measurement of characteristic gamma-ray emissions by high-purity germanium spectrometers offers one means of analysis. Due to the high-activity and complex nature of samples, chemical separations are necessary to reduce background continuum levels and instances of spectral interference. A project has been initiated at Pacific Northwest National Laboratory (PNNL) to model singles and coincident gamma-ray spectra that would result from various chemical separation strategies. The goal is to use these complementary counting techniques to tailor a series of efficient chemical separations that allow the rapid quantification of signature isotopes in samples. Modeling enables probable instances of spectral interference to be identified and aids in defining the temporal window of detection for radionuclides of interest following a given chemical separation. These data will help future analysts prioritize analytes of interest and separation strategies in the processing of real samples. A description of results to date is described here, demonstrating the utility of this approach for improved processing and analysis of fission product samples.

45 MILITARY TECHNOLOGY, WEAPONRY, AND NATIONAL DEF↗

Multi-Isotope Process (MIP) Monitor: A Near-Real-Time Monitor For Reprocessing Facilities

INTRODUCTION The threat of protracted diversion of Pu from commercial reprocessing operations is perhaps the greatest concern to national and international agencies tasked with safeguarding these facilities. While it is generally understood that a method for direct monitoring of process on-line and in near-real time (NRT) would be the best defense against protracted diversion scenarios, an effective method with these qualities has yet to be developed. Here, we attempt to bridge this gap by proposing an on-line NRT process monitoring method that should be sensitive to minor alterations in process conditions and compatible with small, easily deployable, detection systems. This Approach is known as the Multi-Isotope Process (MIP) Monitor and involves the determination and recognition of the contaminant pattern within a process stream for a suite of indicator (radioactive) elements present in the spent fuel as a function of process variables. Utilization of a suite of radio-elements, including ones with multiple oxidation states, decreases the likelihood that attempts to divert Pu by altering the ReDox environment within the process would go undetected. In addition, by identifying gamma-emitting indicator isotopes, this Approach might eliminate the need for bulky neutron detection systems, relying instead on small, portable, high-resolution gamma detectors easily deployable throughout the facility.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

A Green Approach to SNF Reprocessing: Are Common Household Reagents the Answer?

It has been discovered that UO2, the principal component of spent nuclear fuel (SNF), can efficiently be dissolved at room temperature using a combination of common household reagents, namely hydrogen peroxide, baking soda, and ammonia. This rather serendipitous discovery opens up the possibility, for the first time, of considering a non-acidic process for recycling U from SNF. Albeit at the early stages of development, our unconventional dissolution approach possesses many attractive features that could make it a reality in the future. With dissolution byproducts of water and oxygen, our approach poses a minimal threat to the environment. Moreover, the use of common household reagents to afford actinide oxide dissolution suggests a certain degree of economic favorability. With the use of a “closed” digestion vessel as a reaction chamber, our approach has substantial versatility with the option of using either aqueous or gaseous reactant feeds or a combination of both. Our approach distinguishes itself from all existing reprocessing technologies in two important ways. First and foremost, it is an alkaline rather than an acidic process, using mild non-corrosive chemicals under ambient conditions to effect actinide separations. Secondly, it does not dissolve the entire SNF matrix, but rather selectively solubilizes U and other light actinides for subsequent separation, resulting in potentially faster head-end dissolution and fewer downstream separation steps. From a safeguards perspective, the use of oxidizing alkaline solutions to effect actinide separations also potentially offers a degree of inherent proliferation resistance, by allowing the U to be selectively removed from the remaining dissolver solution while keeping Pu grouped with the other minor actinides and fission products. This paper will describe the design and general experimental setup of a “closed” digestion vessel for performing uranium oxide dissolutions under alkaline conditions using gaseous reactant feeds, and preliminary data on the parameters affecting the alkaline dissolution of UO2 in aqueous peroxide-containing carbonate systems.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗