Search NASA⌕ Search

Engineering topics

Drąg, Paweł

Publications and source records attributed to Drąg, Paweł.

A modified model parametrization algorithm for solving a special type of heat and mass transfer systems

A new method for solving nonlinear heat and mass transfer design tasks was considered. Systems using the Number of Transfer Units (NTU) method are a special type of mathematical model of heat and mass exchangers. It was observed, that the NTU models in a form of differential-algebraic equations (DAEs) cannot be directly solved with higher values of NTU. The requirements for consistent initial conditions, as well as numerical limitations of DAEs solvers, result, that the solution to the considered design problems that cannot be obtained by a classical direct shooting procedure. To overcome the presented difficulties, the αDAE model optimization algorithm was adjusted for solving NTU-based models. The new approach consists of 3 main steps: 1) task discretization by a multiple-shooting approach, 2) design an appropriate function $f_{NTU}$(α) to effectively influence the variability of the state variables described by dynamical relations, 3) the iterative numerical optimization algorithm for the new parametrized system. Moreover, computations can be performed by a chosen numerical optimization approach, which can be communicated with an available outer procedure for solving differential-algebraic equations. The presented algorithm was implemented and applied to solve the design task with the NTU model of a counter-flow exchanger. Here, the new approach was used to modify the system dynamics to influence the difficulty of the considered problem. Finally, the presented method enabled failure-free numerical computations for the higher values of the NTU parameter.

97 MATHEMATICS AND COMPUTING↗

Numerical and experimental analysis of precooled desiccant system

This paper presents a numerical and experimental study of four novel, desiccant air-conditioning systems based on pre-cooling of the ambient air. The purpose of the study is to: 1) establish which configuration is most profitable for the future studies through numerical and experimental methods; 2) verify the concept of precooled system and confirm that it is working in experimental conditions (for this purpose two prototypes of evaporative cooling units were developed and compared for different operation arrangements with desiccant wheel); 3) Analyze practical aspects of the systems, which includes water consumption analysis, economic analysis and establishing operational modes during a cooling season in temperate climate conditions (the proposed solution has a significant advantage during operation in a temperate climate, since it can utilize its first evaporative cooler the only source of cooling energy when the humidity of outdoor air allows to to meet the latent cooling load). Four arrangements of the system with different dew point evaporative air cooler prototypes were selected and developed for comparative analysis. The system was simulated as a whole, also, each component was individually tested on measurement station. develop the optimal arrangement of the system through numerical and experimental analysis. Four different performance indicators were considered: thermal COP (Coefficient Of Performance), the ERR (Energy Efficiency Ratio), coefficient a describing the potential in compensating indoor cooling loads, water consumption ratio. Also costs of the systems were compared through economic analysis. It was established that arrangement which is characterized by best-averaged performance in terms of all considered factors is a unit combined with two different types of evaporative coolers (marked as System B)- this is caused by the favorable arrangement of two units, where one is better suited to the pre-cooler role, while the other is better suited as the post-cooler.

42 ENGINEERING↗