Search NASA⌕ Search

Engineering topics

Dragonette, Richard

Publications and source records attributed to Dragonette, Richard.

Ground control system for the midcourse space experiment UTC clock

One goal of the Midcourse Space Experiment (MSX) spacecraft Operations Planning Center is to maintain the onboard satellite UTC clock (UTC(MSX)) to within 1 millisecond of UTC(APL) (the program requirement is 10 msec). The UTC(MSX) clock employs as its time base an APL built 5 MHz quartz oscillator, which is expected to have frequency instabilities (aging rate + drift rate + frequency offset) that will cause the clock to drift approximately two to ten milliseconds per day. The UTC(MSX) clock can be advanced or retarded by the APL MSX satellite ground control center by integer multiples of 1 millisecond. The MSX Operations Planning Center is developing software which records the drift of UTC(MSX) relative to UTC(APL) and which schedules the time of day and magnitude of UTC(MSX) clock updates up to 48 hours in advance. Because of the manner in which MSX spacecraft activities are scheduled, MSX clock updates are planned 24 to 48 hours in advance, and stored in the satellite's computer controller for later execution. Data will be collected on the drift of UTC(MSX) relative to UTC(APL) over a three to five day period. Approximately six times per day, the time offset between UTC(MSX) and UTC(APL) will be measured by APL with a resolution of less than 100 microseconds. From this data a second order analytical model of the clock's drift will be derived. This model will be used to extrapolate the offset of the MSX clock in time from the present to 48 hours in the future. MSX clock updates will be placed on the spacecraft's daily schedule whenever the predicted clock offset exceeds 0.5 milliseconds. The paper includes a discussion of how the empirical model of the MSX clock is derived from satellite telemetry data, as well as the algorithm used to schedule MSX clock updates based on the model.

Dragonette, Richard↗

Performance of low-cost commercial fiber-optic transceivers for reference frequency distribution

Precision time and frequency reference signals were effectively disseminated using high-quality intricate fiber-optic distribution systems. The quality of signals distributed by such systems is excellent, but the cost of these systems makes them unavailable to many potential users. A study of signal quality maintained using inexpensive commercial transmitter/receiver pairs is undertaken. Seven different transmitter/receiver pairs obtained from four different manufacturers were thoroughly tested using a 5 MHz sinusoid derived from a precision, temperature controlled, crystal-controlled oscillator. The electrical signal output from each fiber-optic receiver was tested for spectral purity, single-sideband phase noise, and AM noise, and the results are tabulated and discussed without identification of the manufacturer or the equipment model number.

Dragonette, Richard↗