Search NASA⌕ Search

Engineering topics

Drewelow, Peter

Publications and source records attributed to Drewelow, Peter.

EMC3-EIRENE simulation of first wall recycling fluxes in W7-X with relation to H-alpha measurements

In the Wendelstein 7-X stellarator, the main locations of particle sources are expected to be the carbon divertors, baffles and graphite heat shield first wall. In this paper, the heat shield is implemented in EMC3-EIRENE to understand the expected areas and magnitudes of the recycling flux to this component. It is found that in the simulation the heat shield is not a significant source of recycling neutrals. The areas of simulated recycling flux are shown to correlate well with footprints of plasma-wetting seen in post-experimental campaign in-vessel inspection photos. EMC3-EIRENE reconstruction of line-integrated H-alpha measurements at the heat shield indicate that the majority of emission does not come from local recycling neutrals. Rather, the H-alpha signals at the heat shield are dominated by ionization of neutrals which have leaked from the divertor/baffle region into the midplane. The magnitude of the H-alpha line emission from the synthetic reconstruction is consistent with the experiment, indicating that a large overestimation of heat shield recycling would occur if these measurements were assumed to be from local recycling sources. In the future, it may be possible to obtain some information of local recycling from the heat shield since it was found that the majority of the recycling flux occurs on two well-localized areas.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Tuning of the rotational transform in Wendelstein 7-X

The control of rotational transform in Wendelstein 7-X (W7-X) is key to the island divertor operation and safety of plasma facing components. The island divertor concept in W7-X relies on an edge flux surface with rotational transform of $t$ = 1 resonating with an intrinsic n/m = 5/5 resonance to form a five lobed island chain. This island chain intersects with divertor plates to give rise to the island divertor. Changes in the relative position of the rational surface and the divertor plates can result in changes in divertor performance, thus the control of the rotational transform is essential to operation of the W7-X device. During the first divertor campaign electromagnetic loads resulted in elastic deformations of the shaped modular stellarator coils. Such deformations made these coils more planar, reducing the vacuum rotational transform, subsequently shifting the $t$ = 1 resonance outward. Unintended plasma wall interactions provided the first clear evidence of this effect during plasma operation. Flux surface measurements were utilized to estimate the correct level of current in the planar coils for correction of $t$, and found to be around ~-100 A . Scans of the planar coil current for iota correction were performed during plasma operation. These measurements suggest planar coil currents between -250 and ~ 0 A would place the strike lines at the designed distance from the pumping gaps. Divertor Langmuir and upstream probe measurements confirm these estimates along with measurements of divertor neutral gas pressure.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Error fields in the Wendelstein 7-X stellarator

The role of error fields in stellarators is explored in this work through simulations of, and experiments performed on, the Wendelstein 7-X (W7-X) stellarator. Previous experimental results, based on limiter plasmas in W7-X, suggest that error fields are small in the experiment based on limiter plasmas. In this work, we document results from the first divertor campaign on W7-X with a focus on error fields resonant with the edge island divertor structure. Measurements obtained using divertor thermocouples corroborate earlier limiter results that the error fields are small and correctable, requiring only 5% of the total rated current of the trim coil system. The effect of these error fields on magnetic geometry and topology are investigated using the flux surface measurement technique. The resulting divertor thermal load asymmetry is modeled via field line diffusion and compared to experimental data.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Infrared imaging systems for wall protection in the W7-X stellarator (invited)

Here, Wendelstein 7-X aims at quasi-steady state operation with up to 10 MW of heating power for 30 min. Power exhaust will be handled predominantly via 10 actively water cooled CFC (carbon-fiber-reinforced carbon) based divertor units designed to withstand power loads of 10 MW/m 2 locally in steady state. If local loads exceed this value, a risk of local delamination of the CFC and failure of entire divertor modules arises. Infrared endoscopes to monitor all main plasma facing components are being prepared, and near real time software tools are under development to identify areas of excessive temperature rise, to distinguish them from non-critical events, and to trigger alarms. Tests with different cameras were made in the recent campaign. Long pulse operation enforces additional diagnostic design constraints: for example, the optics need to be thermally decoupled from the endoscope housing. In the upcoming experimental campaign, a graphite scraper element, in front of the island divertor throat, will be tested as a possible means to protect the divertor pumping gap edges during the transient discharge evolution.

47 OTHER INSTRUMENTATION↗

Confirmation of the topology of the Wendelstein 7-X magnetic field to better than 1:100,000

Fusion energy research has in the past 40 years focused primarily on the tokamak concept, but recent advances in plasma theory and computational power have led to renewed interest in stellarators. The largest and most sophisticated stellarator in the world, Wendelstein 7-X (W7-X), has just started operation, with the aim to show that the earlier weaknesses of this concept have been addressed successfully, and that the intrinsic advantages of the concept persist, also at plasma parameters approaching those of a future fusion power plant. Here we show the first physics results, obtained before plasma operation: that the carefully tailored topology of nested magnetic surfaces needed for good confinement is realized, and that the measured deviations are smaller than one part in 100,000. Lastly, this is a significant step forward in stellarator research, since it shows that the complicated and delicate magnetic topology can be created and verified with the required accuracy.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

An FPGA-based bolometer for the MAST-U Super-X divertor

A new resistive bolometer system has been developed for MAST-Upgrade. It will measure radiated power in the new Super-X divertor, with millisecond time resolution, along 16 vertical and 16 horizontal lines of sight. The system uses a Xilinx Zynq-7000 series Field-Programmable Gate Array (FPGA) in the D-TACQ ACQ2106 carrier to perform real time data acquisition and signal processing. The FPGA enables AC-synchronous detection using high performance digital filtering to achieve a high signal-to-noise ratio and will be able to output processed data in real time with millisecond latency. The system has been installed on 8 previously unused channels of the JET vertical bolometer system. Initial results suggest good agreement with data from existing vertical channels but with higher bandwidth and signal-to-noise ratio.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Three-dimensional photogrammetric measurement of magnetic field lines in the WEGA stellarator

The magnetic confinement of plasmas in fusion experiments can significantly degrade due to perturbations of the magnetic field. A precise analysis of the magnetic field in a stellarator-type experiment utilizes electrons as test particles following the magnetic field line. The usual fluorescent detector for this electron beam limits the provided information to two-dimensional cut views at certain toroidal positions. However, the technique described in this article allows measuring the three-dimensional structure of the magnetic field by means of close-range photogrammetry. After testing and optimizing the main diagnostic components, measurements of the magnetic field lines were accomplished with a spatial resolution of 5 mm. The results agree with numeric calculations, qualifying this technique as an additional tool to investigate magnetic field configurations in a stellarator. For a possible future application, ways are indicated on how to reduce experimental error sources.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗