Search NASA⌕ Search

Engineering topics

Drouin, B. J.

Publications and source records attributed to Drouin, B. J..

Better Spectrometers, Beautiful Spectra and Confusion for All

The confluence of enormous improvements in submillimeter receivers and the development of powerful large scale observatories is about to force astrophysics and the sciences that support it to develop novel approaches for interpretation of data. The historical method of observing one or two lines and carefully analyzing them in the context of a simple model is now only applicable for distant objects where only a few lines are strong enough to be observable. Modern observatories collect many GHz of high signal-to-noise spectra in a single observation and in many cases, at sufficiently high spatial resolution to start resolving chemically distinct regions. The observatories planned for the near future and the inevitable upgrades of existing facilities will make large spectral data sets the rule rather than the exception in many areas of molecular astrophysics. The methodology and organization required to fully extract the available information and interpret these beautiful spectra represents a challenge to submillimeter astrophysics similar in magnitude to the last few decades of effort in improving receivers. The quality and abundance of spectra effectively prevents line-by-line analysis from being a time efficient proposition, however, global analysis of complex spectra is a science in its infancy. Spectroscopy at several other wavelengths have developed a number of techniques to analyze complex spectra, which can provide a great deal of guidance to the molecular astrophysics community on how to attack the complex spectrum problem. Ultimately, the challenge is one of organization, similar to building observatories, requiring teams of specialists combining their knowledge of dynamical, structural, chemical and radiative models with detailed knowledge in molecular physics and gas and grain surface chemistry to extract and exploit the enormous information content of complex spectra. This paper presents a spectroscopists view of the necessary elements in a tool for complex spectral analysis.

Spectral Analysis↗

Validation of Aura Microwave Limb Sounder HCl Measurements

The Earth Observing System (EOS) Microwave Limb Sounder (MLS) aboard the Aura satellite has provided daily global HCl profiles since August 2004. We provide a characterization of the resolution, random and systematic uncertainties, and known issues for the version 2.2 MLS HCl data. The MLS sampling allows for comparisons with many (~1500 to more than 3000) closely matched profiles from the Halogen Occultation Experiment (HALOE) and Atmospheric Chemistry Experiment Fourier Transform Spectrometer (ACE-FTS). These data sets provide HCl latitudinal distributions that are, overall, very similar to those from (coincident) MLS profiles, although there are some discrepancies in the upper stratosphere between the MLS and HALOE gradients. As found in previous work, MLS and ACE HCl profiles agree very well (within approximately 5%, on average), but the MLS HCl abundances are generally larger (by 10-20%) than HALOE HCl. The bias versus HALOE is unlikely to arise mostly from MLS, as a similar systematic bias (of order 15%) is not observed between average MLS and balloon-borne measurements of HCl, obtained over Fort Sumner, New Mexico, in 2004 and 2005. At the largest pressure (147 hPa) for MLS HCl, a high bias (approximately 0.2 ppbv) is apparent in analyses of low to midlatitude data versus in situ aircraft chemical ionization mass spectrometry (CIMS) HCl measurements from the Aura Validation Experiment (AVE) campaigns in 2004, 2005, and 2006; this bias is also observed in comparisons of MLS and aircraftHCl/O3 correlations. Good agreement between MLS and CIMS HCl is obtained at 100 to 68 hPa. The recommended pressure range for MLS HCl is from 100 to 0.15 hPa.

Earth Observing System (EOS)↗

Validation of Aura Microwave Limb Sounder O3 and CO Observations in the Upper Troposphere and Lower Stratosphere

Global satellite observations of ozone and carbon monoxide from the Microwave Limb Sounder (MLS) on the EOS Aura spacecraft are discussed with emphasis on those observations in the 2 15 - 100 hPa region (the upper troposphere and lower stratosphere). The precision, resolution and accuracy of the data produced by the MLS "version 2.2" processing algorithms are discussed and quantified. O3 accuracy is estimated at approx.40 ppbv +5% (approx.20 ppbv +20% at 215 hPa) while the CO accuracy is estimated at approx.30 ppbv +30% for pressures of 147 hPa and less. Comparisons with expectations and other observations show good agreements for the O3 product, generally consistent with the systematic errors quoted above. In the case of COY a persistent factor of approx.2 high bias is seen at 215 hPa. However, the morphology is shown to be realistic, consistent with raw MLS radiance data, and useful for scientific study. The MLS CO data at higher altitudes are shown to be consistent with other observations.

Livesey, N. J.↗

Validation of Aura Microwave Limb Sounder Ozone by Ozonesonde and Lidar Measurements

We present validation studies of MLS version 2.2 upper tropospheric and stratospheric ozone profiles using ozonesonde and lidar data as well as climatological data. Ozone measurements from over 60 ozonesonde stations worldwide and three lidar stations are compared with coincident MLS data. The MLS ozone stratospheric data between 150 and 3 hPa agree well with ozonesonde measurements, within 8% for the global average. MLS values at 215 hPa are biased high compared to ozonesondes by approximately 20% at middle to high latitude, although there is a lot of variability in this altitude region.

validation studies↗

Validation of the Aura Microwave Limb Sounder middle atmosphere water vapor and nitrous oxide measurements

The quality of the version 2.2 (v2.2) middle atmosphere water vapor and nitrous oxide measurements from the Microwave Limb Sounder (MLS) on the Earth Observing System (EOS) Aura satellite is assessed. The impacts of the various sources of systematic error are estimated by a comprehensive set of retrieval simulations. Comparisons with correlative data sets from ground-based, balloon and satellite platforms operating in the UV/visible, infrared and microwave regions of the spectrum are performed. Precision estimates are also validated, and recommendations are given on the data usage. The v2.2 H2O data have been improved over v1.5 by providing higher vertical resolution in the lower stratosphere and better precision above the stratopause. The single-profile precision is ~0.2–0.3 ppmv (4–9%), and the vertical resolution is ~3–4 km in the stratosphere. The precision and vertical resolution become worse with increasing height above the stratopause. Over the pressure range 0.1–0.01 hPa the precision degrades from 0.4 to 1.1 ppmv (6–34%), and the vertical resolution degrades to ~12–16 km. The accuracy is estimated to be 0.2–0.5 ppmv (4–11%) for the pressure range 68–0.01 hPa. The scientifically useful range of the H2O data is from 316 to 0.002 hPa, although only the 82–0.002 hPa pressure range is validated here. Substantial improvement has been achieved in the v2.2 N2O data over v1.5 by reducing a significant low bias in the stratosphere and eliminating unrealistically high biased mixing ratios in the polar regions. The single-profile precision is ~13–25 ppbv (7–38%), the vertical resolution is ~4–6 km and the accuracy is estimated to be 3–70 ppbv (9–25%) for the pressure range 100–4.6 hPa. The scientifically useful range of the N2O data is from 100 to 1 hPa.

Atlas, E.↗

Validation of the Aura Microwave Limb Sounder Temperature and Geopotential Height Measurements

This paper describes the retrievals algorithm used to determine temperature and height from radiance measurements by the Microwave Limb Sounder on EOS Aura. MLS is a "limbscanning" instrument, meaning that it views the atmosphere along paths that do not intersect the surface - it actually looks forwards from the Aura satellite. This means that the temperature retrievals are for a "profile" of the atmosphere somewhat ahead of the satellite. Because of the need to view a finite sample of the atmosphere, the sample spans a box about 1.5km deep and several tens of kilometers in width; the optical characteristics of the atmosphere mean that the sample is representative of a tube about 200-300km long in the direction of view. The retrievals use temperature analyses from NASA's Goddard Earth Observing System, Version 5 (GEOS-5) data assimilation system as a priori states. The temperature retrievals are somewhat deperrde~zt on these a priori states, especially in the lower stratosphere. An important part of the validation of any new dataset involves comparison with other, independent datasets. A large part of this study is concerned with such comparisons, using a number of independent space-based measurements obtained using different techniques, and with meteorological analyses. The MLS temperature data are shown to have biases that vary with height, but also depend on the validation dataset. MLS data are apparently biased slightly cold relative to correlative data in the upper troposphere and slightly warm in the middle stratosphere. A warm MLS bias in the upper stratosphere may be due to a cold bias in GEOS-5 temperatures.

Schwartz, M. J.↗

Microwave, Millimeter, Submillimeter, and Far Infrared Spectral Databases

The spectrum of most known astrophysical molecules is derived from transitions between a few hundred to a few hundred thousand energy levels populated at room temperature. In the microwave and millimeter wave regions. spectroscopy is almost always performed with traditional microwave techniques. In the submillimeter and far infrared microwave technique becomes progressively more technologically challenging and infrared techniques become more widely employed as the wavelength gets shorter. Infrared techniques are typically one to two orders of magnitude less precise but they do generate all the strong features in the spectrum. With microwave technique, it is generally impossible and rarely necessary to measure every single transition of a molecular species, so careful fitting of quantum mechanical Hamiltonians to the transitions measured are required to produce the complete spectral picture of the molecule required by astronomers. The fitting process produces the most precise data possible and is required in the interpret heterodyne observations. The drawback of traditional microwave technique is that precise knowledge of the band origins of low lying excited states is rarely gained. The fitting of data interpolates well for the range of quantum numbers where there is laboratory data, but extrapolation is almost never precise. The majority of high resolution spectroscopic data is millimeter or longer in wavelength and a very limited number of molecules have ever been studied with microwave techniques at wavelengths shorter than 0.3 millimeters. The situation with infrared technique is similarly dire in the submillimeter and far infrared because the black body sources used are competing with a very significant thermal background making the signal to noise poor. Regardless of the technique used the data must be archived in a way useful for the interpretation of observations.

Pearson, J. C.↗