Comparisons of dosimetric accuracy and calculation time of ARCHER and MCNP5 codes for the Ir-192 brachytherapy case - Paper 1

In the last decade, the graphics processing unit (GPU) technology has emerged as a viable player in high-performance computing. A GPU card is designed to carry out thousands of single instructions simultaneously, showing unprecedented computing power when compared with the traditional CPU technology. It has been proved that some computationally intensive programs can be accelerated drastically on the GPUs including Monte Carlo simulations. Unfortunately, existing production Monte Carlo codes cannot be easily ported to the GPU environment. To address the needs, a new Monte Carlo code ARCHER (Accelerated Radiation-transport Computations in Heterogeneous Environment) is being developed at Rensselaer Polytechnic Institute, employing the latest GPU and the Intel Xeon Phi coprocessor technologies. We can execute the code which was written using C and C++ on both CPU and GPU platforms. The ARCHER GPU code was written in CUDA C 5.0 and was tested on the Tesla M2090. There have been a few studies testing the ARCHER GPU code on several different platforms. In particular, Su et al has tested the ARCHER for external-beam radiation treatment 20 MeV monoenergetic monodirectional parallel electron beam. The comparison of the calculation results between EGSnrc and ARCHERGPU was impressive. A remarkable 224- fold speed-up factor was obtained using a NVIDIA Tesla M2090 GPU compared to a CPU. In this study, we applied the ARCHER code to dose calculation for a relatively new procedure, called accelerated partial breast irradiation (APBI) brachytherapy. The APBI brachytherapy dose calculation was based on RPI-AF phantom which is a 3D heterogeneous patient model. We then compared the dosimetric accuracy and calculation times of ARCHER and MCNP5 to gain insight into the accuracy and speedup of the GPU-based ARCHER code. (authors)

61 RADIATION PROTECTION AND DOSIMETRY↗

Parallel Monte Carlo Methods for Heterogeneous Hardware Computer Systems Using GPUs and Coprocessors: Recent Development of ARCHER Code - Paper 54

Traditional methods of accelerating Monte Carlo (MC) calculations typically use CPUs as the computing unit. The parallelism is based upon multithreading on a multi-core processor, and message passing interface (MPI) across many processors and nodes. In recent years, the hardware accelerators have been introduced by the high performance computing industry as an alternative approach to achieve massive parallelism. Hardware accelerators have the advantage of high Floating-point Operations Per Second (FLOPS) and high energy efficiency. Examples include graphics processing units (GPUs) and coprocessors. Compute-intensive programs can be off-loaded to them to be concurrently executed by hundreds or thousands of active threads. Existing production MC codes, however, cannot be directly compiled or executed on the new platforms. It is therefore necessary to rewrite or redevelop the code using the hardware accelerator specific programming models and APIs. Several studies have been conducted on using GPUs to accelerate MC calculations in reactor analysis and medical physics. In this paper, we present the recent progress at Rensselaer Polytechnic Institute (RPI) in developing a new parallel MC code called ARCHER (Accelerated Radiation-transport Computations in Heterogeneous Environments) for coupled photon-electron transport simulations. The code is designed as a test bed to evaluate the efficacy of heterogeneous computing systems for low-cost MC-based radiation dosimetric calculations. The code has three variants corresponding to three parallel hardware platforms: ARCHER-CPU (multi-core CPU), ARCHER-GPU (Nvidia GPU) and ARCHER-COP (Intel Xeon Phi coprocessor). The code has been used for several applications, including CT imaging dosimetry, radiotherapy dosimetry and radiation shielding design. (authors)

61 RADIATION PROTECTION AND DOSIMETRY↗

Development of CSG-based radiation shielding module for ARCHER: preliminary results for photons - Paper 126

ARCHER is a parallel Monte Carlo radiation transport code being developed for various hardware platforms including multi-core CPUs, the emerging Nvidia graphics processing units (GPUs) and Intel Xeon Phi coprocessors. Previous studies have demonstrated the accuracy and speed for CT imaging and radiotherapy dosimetry applications. Radiation shielding applications, however, require ARCHER to be more flexible in defining and handling geometries, in addition to the voxel phantom geometries that are commonly used in medical physics calculations. In this paper, we present the development of a general geometry module used for radiation protection and shielding problems in ARCHER. The methods of geometry design and particle transport for the GPUs are introduced. Preliminary results comparing against the MCNP code for cases involving Cs-137 0.662 MeV gammas are reported. The radiation shielding design module of ARCHER has been developed, which supports general geometry setups in the CSG format. The code was implemented using CUDA on Nvidia GPUs, and the performance was benchmarked against the MCNP code for a simple radiation shielding problem. Results showed that ARCHER worked properly and achieved impressive speedup due to highly parallel computing nature of the Nvidia GPUs compared to the MCNP code running on multi-core CPUs. Further optimization of the geometry module will be carried out using advanced geometry structures and variance reduction techniques to improve the precision and performance of ARCHER. (authors)

61 RADIATION PROTECTION AND DOSIMETRY↗

ARCHER{sub RT} – A GPU-based and photon-electron coupled Monte Carlo dose computing engine for radiation therapy: Software development and application to helical tomotherapy

Purpose: Using the graphical processing units (GPU) hardware technology, an extremely fast Monte Carlo (MC) code ARCHER{sub RT} is developed for radiation dose calculations in radiation therapy. This paper describes the detailed software development and testing for three clinical TomoTherapy® cases: the prostate, lung, and head and neck. Methods: To obtain clinically relevant dose distributions, phase space files (PSFs) created from optimized radiation therapy treatment plan fluence maps were used as the input to ARCHER{sub RT}. Patient-specific phantoms were constructed from patient CT images. Batch simulations were employed to facilitate the time-consuming task of loading large PSFs, and to improve the estimation of statistical uncertainty. Furthermore, two different Woodcock tracking algorithms were implemented and their relative performance was compared. The dose curves of an Elekta accelerator PSF incident on a homogeneous water phantom were benchmarked against DOSXYZnrc. For each of the treatment cases, dose volume histograms and isodose maps were produced from ARCHER{sub RT} and the general-purpose code, GEANT4. The gamma index analysis was performed to evaluate the similarity of voxel doses obtained from these two codes. The hardware accelerators used in this study are one NVIDIA K20 GPU, one NVIDIA K40 GPU, and six NVIDIA M2090 GPUs. In addition, to make a fairer comparison of the CPU and GPU performance, a multithreaded CPU code was developed using OpenMP and tested on an Intel E5-2620 CPU. Results: For the water phantom, the depth dose curve and dose profiles from ARCHER{sub RT} agree well with DOSXYZnrc. For clinical cases, results from ARCHER{sub RT} are compared with those from GEANT4 and good agreement is observed. Gamma index test is performed for voxels whose dose is greater than 10% of maximum dose. For 2%/2mm criteria, the passing rates for the prostate, lung case, and head and neck cases are 99.7%, 98.5%, and 97.2%, respectively. Due to specific architecture of GPU, modified Woodcock tracking algorithm performed inferior to the original one. ARCHER{sub RT} achieves a fast speed for PSF-based dose calculations. With a single M2090 card, the simulations cost about 60, 50, 80 s for three cases, respectively, with the 1% statistical error in the PTV. Using the latest K40 card, the simulations are 1.7–1.8 times faster. More impressively, six M2090 cards could finish the simulations in 8.9–13.4 s. For comparison, the same simulations on Intel E5-2620 (12 hyperthreading) cost about 500–800 s. Conclusions: ARCHER{sub RT} was developed successfully to perform fast and accurate MC dose calculation for radiotherapy using PSFs and patient CT phantoms.