Search NASA⌕ Search

Engineering topics

Dubois, M

Publications and source records attributed to Dubois, M.

WE-G-204-08: Optimized Digital Radiographic Technique for Lost Surgical Devices/Needle Identification

Purpose: Small surgical devices and needles are used in many surgical procedures. Conventionally, an x-ray film is taken to identify missing devices/needles if post procedure count is incorrect. There is no data to indicate smallest surgical devices/needles that can be identified with digital radiography (DR), and its optimized acquisition technique. Methods: In this study, the DR equipment used is a Canon RadPro mobile with CXDI-70c wireless DR plate, and the same DR plate on a fixed Siemens Multix unit. Small surgical devices and needles tested include Rubber Shod, Bulldog, Fogarty Hydrogrip, and needles with sizes 3-0 C-T1 through 8-0 BV175-6. They are imaged with PMMA block phantoms with thickness of 2–8 inch, and an abdomen phantom. Various DR techniques are used. Images are reviewed on the portable x-ray acquisition display, a clinical workstation, and a diagnostic workstation. Results: all small surgical devices and needles are visible in portable DR images with 2–8 inch of PMMA. However, when they are imaged with the abdomen phantom plus 2 inch of PMMA, needles smaller than 9.3 mm length can not be visualized at the optimized technique of 81 kV and 16 mAs. There is no significant difference in visualization with various techniques, or between mobile and fixed radiography unit. However, there is noticeable difference in visualizing the smallest needle on a diagnostic reading workstation compared to the acquisition display on a portable x-ray unit. Conclusion: DR images should be reviewed on a diagnostic reading workstation. Using optimized DR techniques, the smallest needle that can be identified on all phantom studies is 9.3 mm. Sample DR images of various small surgical devices/needles available on diagnostic workstation for comparison may improve their identification. Further in vivo study is needed to confirm the optimized digital radiography technique for identification of lost small surgical devices and needles.

60 APPLIED LIFE SCIENCES↗

Status of the SPIRAL I upgrade at GANIL

The upgrade of the ''Systeme de Production d'Ions Radioactifs en Ligne'' phase I (SPIRAL I) installed at the ''Grand Accelerateur National d'Ions Lourds'' (GANIL) situated at Caen, France, is in progress and should be ready by 2014. In parallel, the first part of SPIRAL II facility is currently under construction. The global status of the upgrade is presented: goal, radioactive ion production systems, modification of the production cave and impact of the current safety re-evaluation of GANIL.

43 PARTICLE ACCELERATORS↗

Multigan: First experimental results

A new design of a multicharged ion source based on the MONO1000 ECRIS has been presented at the last ECR ion source (ECRIS) Workshop 2010. [L. Maunoury et al., in Proceedings of the XIXth International Workshop on ECR Ion Sources, Grenoble, France, 23-26 August 2010] This source has not only two opening at both ends but also a large space in the middle of the source enabling a direct contact with the ECR plasma. The source has been assembled mechanically and put on a test bench at the Pantechnik company. The primary tests have shown that the plasma ignition occurred at low pressure (10{sup -6} mbar) and low RF power (10 W). The first experimental results ( = 1.30 for Ar and 1.85 for Xe) demonstrated the potential of this ion source in production of multicharged ion beams.

43 PARTICLE ACCELERATORS↗

Status of the ion sources developments for the Spiral2 project at GANIL

The SPIRAL 2 facility is now under construction and will deliver either stable or radioactive ion beams. First tests of nickel beam production have been performed at GANIL with a new version of the large capacity oven, and a calcium beam has been produced on the heavy ion low energy beam transport line of SPIRAL 2, installed at LPSC Grenoble. For the production of radioactive beams, several target/ion-source systems (TISSs) are under development at GANIL as the 2.45 GHz electron cyclotron resonance ion source, the surface ionization source, and the oven prototype for heating the uranium carbide target up to 2000 deg. C. The existing test bench has been upgraded for these developments and a new one, dedicated for the validation of the TISS before mounting in the production module, is under design. Results and current status of these activities are presented.

43 PARTICLE ACCELERATORS↗

Development of a surface ionization source for the SPIRAL 2 project

Development of new radioactive beams, and thus of new target ion sources (TISs) for isotope-separator-on-line production systems are in progress at GANIL for the SPIRAL 2 project. The efficiency and time response measurements of each step in the production process are crucial to predict and maximize the available yields, in particular, for short lived isotopes. This paper presents a method for measuring these quantities that makes use of a stable alkali chopped beam of controlled intensity. This method was applied to surface ionization source test for high efficiency. Results of recent experiments are presented that include ionization efficiency measurements for Cs, Rb, K, Na, and Li with a graphite and rhenium ionizer and dwell time of these alkalis on graphite. The results enabled to design a first surface ionization source prototype which will be installed in the SPIRAL 2 TIS.

43 PARTICLE ACCELERATORS↗

Latest developments at GANIL for stable and radioactive ion beam production

In the frame of the SPIRAL II (Systeme de Production d'Ions Radioactifs Acceleres en Ligne Partie II) project, several developments of stable and radioactive ion production systems have been started up. In parallel, GANIL has the ambition to preserve the existing stable and radioactive beams and also to increase its range by offering new ones. In order to identify the best directions for this development, a new group called GANISOL has been formed. Its preliminary conclusions and the latest developments at GANIL are presented.

43 PARTICLE ACCELERATORS↗

Direct 1{sup +}{yields}N{sup +} conversion of stable alkali ions using an electron cyclotron resonance ion source

The production of radioactive ions using the Isotope Separation On-Line method gives rise, in most cases, to singly charged ions. In order to perform experiments with postaccelerated radioactive ion beams, these ions have to be multicharged. We describe here a new compact design for a charge breeder that will be coupled to the production target of SPIRAL1 at GANIL. We present recent results obtained offline with stable alkali ions (Na, K, Rb, and Cs) on the SIRa test bench. Particularly, 1{sup +} to N{sup +} conversion efficiencies and conversion times are presented. Several points have been identified for the improvements of the present performances.

43 PARTICLE ACCELERATORS↗

GISELE: A resonant ionization laser ion source for the production of radioactive ions at GANIL

SPIRAL2 is the new project under construction at GANIL to produce radioactive ion beams and in particular neutron rich ion beams. For the past 10 yr SPIRAL1 at GANIL has been delivering accelerated radioactive ion beams of gases. Both facilities now need to extend the range of radioactive ion beams produced to condensable elements. For that purpose, a resonant ionization laser ion source, funded by the French Research National Agency, is under development at GANIL, in collaboration with IPN Orsay, University of Mainz (Germany) and TRIUMF, Vancouver (Canada). A description of this project called GISELE (GANIL Ion Source using Electron Laser Excitation) is presented.

43 PARTICLE ACCELERATORS↗

Addendum to papers from the GANIL (Grand Accelerateur National d'Ions Lourds) GANISOL Team, published in Proceedings of the 13th International Conference on Ion Sources, Gatlinburg, Tennessee, September 2009

This addendum applies to the paper authored by contributors from the Grand Accelerateur National d'Ions Lourds (GANIL) published in the February 2010 issue of Review of Scientific Instruments, within the Proceedings of the 13th International Conference on Ion Sources, Gatlinburg, Tennessee, September 2009 (Key Scientific coordinator: P. Delahaye; Technical coordinator: P. Jardin; SPIRAL 2 coordinator: R. Leroy and H. Fraanberg-Delahaye; GPI leader: P. Leherissier; and Direction correspondant: P. Roussel-Chomaz). This addendum provides the full list of GANISOL contributors and their affiliations.

43 PARTICLE ACCELERATORS↗

Status report of stable and radioactive ion beam production at GANIL

GANIL has been producing many stable and radioactive ion beams for nearly 25 years. Constant progresses have been made in terms of intensity, stability, and reliability. The intensity for some stable metallic beams now exceeds or approaches the p {mu}A level at an energy up to 95 MeV/u, e.g., 1.14 p {mu}A for {sup 36}S (65% enriched) at 77 MeV/u, 0.35 p {mu}A for {sup 58}Ni (63% enriched) at 74 MeV/u. Some recent results with Magnesocene using the metallic ions from volatile compounds method should also make possible the production of metallic beams with an intensity greater than 1 p {mu}A. This has still to be measured. The ISOL facility SPIRAL I has been in operation for almost six years. Up to now, 17 exotic He experiments have been done with 14 target/ion-source (TIS) units; 19 other experiments (with O, Ne, Ar, and Kr) have been achieved with 14 TISs. Statistics show a fairly good ratio of available beam time to scheduled beam time. The radioactive beams and available intensities are compiled in this report. Future developments on radioactive ion beam production are briefly presented, while more details will be discussed elsewhere at this conference.

43 PARTICLE ACCELERATORS↗

Development of a 1+/N+ setup for the production of multicharged radioactive alkali ions in SPIRAL

In the framework of the production of radioactive ion beams by the isotope separator online method, a new system has been developed at GANIL/SPIRAL I to produce multicharged alkali ions. The principle, referred to as the ''direct 1+/N+ method,'' consists of a surface ionization source associated with a multicharged electron-cyclotron-resonance ion source without an intermediate mass separator. This new system has been tested online using a {sup 48}Ca primary beam at 60.3 A MeV. The experimental evidence of the direct 1+/N+ process has been obtained for a potential difference between the two sources of 11 V and with a 1+/N+ charge breeding efficiency of 0.04% for {sup 47}K{sup 5+}. This value is significantly lower than the value of 6% obtained for stable K ions with the standard 1+/N+ method. A possible explanation is given in the text.

07 ISOTOPE AND RADIATION SOURCES↗

Structural investigations of sol-gel-derived LiYF{sub 4} and LiGdF{sub 4} powders

A soft synthesis route based on the sol-gel process was used for preparing rare-earth tetrafluoride powders from alkoxide precursors. In-situ fluorination was performed by decomposition of a fluorine containing organic compound named 1,1,1-trifluoro-5-methyl-2,4-hexanedione when sintering the as-prepared xerogel to produce crystallized samples. Both to insure complete departure of organic residues as well as to avoid any oxidation into oxyfluoride, annealing treatment was carried out under fluorine atmosphere. Free-oxygen content of resulting samples was evidenced by infrared and Raman spectroscopies. X-ray absorption spectroscopies (XAS) and {sup 19}F nuclear magnetic resonance (NMR) studies showed that samples heat treated at 300 deg. C are already crystallized but for a full crystallization in LiGdF{sub 4} and LiYF{sub 4} a thermal treatment at 550 deg. C is needed. Temperature dependence of powder morphology was analyzed by scanning electron microscopy (SEM). - Graphical abstract: The sol-gel route is a soft process, which allows developing versatile-shaped compounds. A fluorine organic compound named 1,1,1-trifluoro-5-methyl-2,4-hexadione was used to synthesis LiGdF{sub 4} and LiYF{sub 4} powders based on the sol-gel method. These materials can be used as host lattices for rare-earth ions to provide phosphors.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗