Search NASASearch

Engineering topics

Duncan, Michael

Publications and source records attributed to Duncan, Michael.

NASA Data Acquisitions System (NDAS) Software Architecture

The NDAS Software Project is for the development of common low speed data acquisition system software to support NASA's rocket propulsion testing facilities at John C. Stennis Space Center (SSC), White Sands Test Facility (WSTF), Plum Brook Station (PBS), and Marshall Space Flight Center (MSFC).

Davis, Dawn

Space Life Sciences Directorate's Position on the Physiological Effects of Exposing the Crewmemeber to Low-Voltage Electrical Hazards During Extravehicular Activity

The models predict that, for low voltage exposures in the space suit, physiologically active current could be conducted across the crew member causing catastrophic hazards. Future work with Naval Health Research Center Detachment Directed Energy Bio-effects Laboratory is being proposed to analyze additional current paths across the human torso and upper limbs. These models may need to be verified with human studies.

Hamilton, Douglas

Validation of On-Orbit Methodology for the Assessment of Cardiac Function and Changes in the Circulating Volume Using Ultrasound and Braslet-M Occlusion Cuffs

The objective of this joint U.S. - Russian project was the development and validation of an in-flight methodology to assess a number of cardiac and vascular parameters associated with circulating volume and its manipulation in long-duration space flight. Responses to modified Valsalva and Mueller maneuvers were measured by cardiac and vascular ultrasound (US) before, during, and after temporary volume reduction by means of Braslet-M thigh occlusion cuffs (Russia). Materials and Methods: The study protocol was conducted in 14 sessions on 9 ISS crewmembers, with an average exposure to microgravity of 122 days. Baseline cardiovascular measurements were taken by echocardiography in multiple modes (including tissue Doppler of both ventricles) and femoral and jugular vein imaging on the International Space Station (ISS). The Braslet devices were then applied and measurements were repeated after >10 minutes. The cuffs were then released and the hemodynamic recovery process was monitored. Modified Valsalva and Mueller maneuvers were used throughout the protocol. All US data were acquired by the HDI-5000 ultrasound system aboard the ISS (ATL/Philips, USA) during remotely guided sessions. The study protocol, including the use of Braslet-M for this purpose, was approved by the ISS Human Research Multilateral Review Board (HRMRB). Results: The effects of fluid sequestration on a number of echocardiographic and vascular parameters were readily detectable by in-flight US, as were responses to respiratory maneuvers. The overall volume status assessment methodology appears to be valid and practical, with a decrease in left heart lateral E (tissue Doppler) as one of the most reliable measures. Increase in the femoral vein cross-sectional areas was consistently observed with Braslet application. Other significant differences and trends within the extensive cardiovascular data were also observed. (Decreased - RV and LV preload indices, Cardiac Output, LV E all maneuvers, LV Stroke Volume). Conclusions: This Study: 1) Addressed specific aspects of operational space medicine and space physiology, including assessment of circulating volume disturbances 2) Expanded the applications of diagnostic ultrasound imaging and Doppler techniques in microgravity. 3) Used respiratory maneuvers against the background of acute circulating volume manipulations which appear to enhance our ability to noninvasively detect volume-dependency in a number of cardiac and vascular parameters. 4) Determined that Tei index is not clinically changed therefore contractility not altered in the face of reduced preload. 5) Determined that increased Femoral Vein Area indicating blood being sequestered in lower extremities correlates with reduced preload and cardiac output. 6) That Braslet may be the only feasible means of acutely treating high pressure pulmonary edema in reduced gravity environments.

Hamilton, Douglas

Prebreathe Protocol for Extravehicular Activity Technical Consultation Report

In the performance of EVA by that National Aeronautics and Space Administration (NASA) astronauts, there exists a risk of DCS as the suit pressure is reduced to 4.3 pounds per square inch, absolute (psia) from the International Space Station (ISS) pressure of 14.7 psia. Several DCS-preventive procedures have been developed and implemented. Each of these procedures involve the use of oxygen (O2) prebreathe to effectively washout tissue nitrogen (N2).The management of the ISS Programs convened an expert independent peer review Team to conduct a review of the Decompression Sickness (DCS) risks associated with the Extra Vehicular Activity (EVA) Campout Prebreathe (PB) protocol for its consideration for use on future missions. The major findings and recommendations of the expert panel are: There is no direct experimental data to confirm the potential DCS risks of the Campout PB protocol. However, based on model data, statistical probability, physiology, and information derived from similar PB protocols, there is no compelling evidence to suggest that the Campout PB protocol is less safe than the other NASA approved PB protocols.

Ross, Jerry