Search NASA⌕ Search

Engineering topics

Dunham, G. S.

Publications and source records attributed to Dunham, G. S..

Development of a high performance MagLIF target platform using high aspect ratio coated liners and low-mix laser preheat

We report on a series of Magnetized Liner Inertial Fusion (MagLIF) experiments conducted on the Z pulsed power facility that utilized high aspect ratio (ratio of outer radius to wall thickness) liners with dielectric coatings and low-mix laser preheat configurations. The liners consisted of an aspect ratio of 10.6 beryllium tube coated with 75 μm of epoxy on the outside that have been shown to maintain a better implosion stability than uncoated beryllium and have demonstrated consistent stagnation performances in previous experiments [Ampleford et al., Phys. Plasmas 31, 022703 (2024)]. Two-dimensional HYDRA simulations were used to design three different “co-injection” laser configurations, whereby a second laser is used to provide an early prepulse before the main pulse, to reduce LEH foil mix while increasing the fuel density and coupled energy. The laser preheat energy for each configuration was constrained using dedicated laser experiments before being applied to the integrated MagLIF experiments on Z. The DD neutron yield for experiments using co-injection preheat configurations is found to increase with the specific preheat energy in line with simulations. The highest neutron yield achieved in this study of 1.1 × 10 13 matches the highest reported in a MagLIF experiment to date and is a factor 3.5 times higher than similar experiments using preheat with no phase plate smoothing. We attempt to assess the effects of mix and morphology to explain the improved performance; however, neither factor is found to be conclusive within the uncertainty of the measurements.

Harvey-Thompson, A. J.↗

X-ray self-emission imaging with spherically bent Bragg crystals on the Z-machine

Here, an x-ray imaging scheme using spherically bent crystals was implemented on the Z-machine to image x rays emitted by the hot, dense plasma generated by a Magnetized Liner Inertial Fusion (MagLIF) target. This diagnostic relies on a spherically bent crystal to capture x-ray emission over a narrow spectral range (<15 eV), which is established by a limiting aperture placed on the Rowland circle. The spherical crystal optic provides the necessary high-throughput and large field-of-view required to produce a bright image over the entire, one-cm length of the emitting column of a plasma. The average spatial resolution was measured and determined to be 18 µm for the highest resolution configuration. With this resolution, the radial size of the stagnation column can be accurately determined and radial structures, such as bifurcations in the column, are clearly resolved. The success of the spherical-crystal imager has motivated the implementation of a new, two-crystal configuration for identifying sources of spectral line emission using a differential imaging technique.

47 OTHER INSTRUMENTATION↗

Background measurement methods for opacity experiments conducted at the Z facility

Laboratory experiments typically test opacity models by measuring spectrally resolved transmission of a sample using bright backlight radiation. A potential problem is that any unaccounted background signal contaminating the spectrum will artificially reduce the inferred opacity. Methods developed to measure background signals in opacity experiments at the Sandia Z facility are discussed. Preliminary measurements indicate that backgrounds are 9%–11% of the backlight signal at wavelengths less than 10 Å. Background is thus a relatively modest correction for all Z opacity data published to date. Future work will determine how important background is at longer wavelengths.

47 OTHER INSTRUMENTATION↗

Review of pulsed power-driven high energy density physics research on Z at Sandia

Pulsed power accelerators compress electrical energy in space and time to provide versatile experimental platforms for high energy density and inertial confinement fusion science. The 80-TW “Z” pulsed power facility at Sandia National Laboratories is the largest pulsed power device in the world today. Z discharges up to 22 MJ of energy stored in its capacitor banks into a current pulse that rises in 100 ns and peaks at a current as high as 30 MA in low-inductance cylindrical targets. Considerable progress has been made over the past 15 years in the use of pulsed power as a precision scientific tool. This paper reviews developments at Sandia in inertial confinement fusion, dynamic materials science, x-ray radiation science, and pulsed power engineering, with an emphasis on progress since a previous review of research on Z in Physics of Plasmas in 2005.

Sinars, D. B. (ORCID:0000000155473532)↗

Ion composition and temperature in the topside ionosphere.

Particle and energy continuity equations derived and solved by computer method ion composition and plasma temperature measured by Explorer XXII PARTICLE and energy continuity equations derived and solved by computer method for ion composition and plasma temperature measured by Explorer XXII

IONOSPHERIC ION DENSITY↗