Search NASA⌕ Search

Engineering topics

Dupont, Mathieu N.

Publications and source records attributed to Dupont, Mathieu N..

26 records · Page 2

Critical Experiment Design Phase 2 Report for Integral Request 304

This report documents the second phase of the critical experiment design process (CED-2) conducted as part of integral experiment request (IER) 304. The purpose of IER-304 is to develop a temperature-dependent critical experiment capability at the Sandia National Laboratories critical experiment facility using low-enriched uranium oxide fuel. Only a few benchmark quality critical experiments are currently available to validate criticality safety computational methods at temperatures other than room temperature. Recent advancements in computational techniques such as implementation of on-the-fly Doppler broadening techniques and advanced treatment of thermal scattering data necessitate the development of additional experimental capabilities in this area. The work described in this report developed representative configurations using 7uPCX and BUCCX fuels, analyzed the physics exercised by the different arrays, and analyzed the estimated experimental uncertainties. This report also scopes the information necessary for performing modifications to the reactor to accommodate operation at elevated and reduced temperatures.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

KENO V.a Primer: Performing Calculations using SCALE’s Criticality Safety Analysis Sequence (CSAS5) with Fulcrum

The SCALE code system developed at Oak Ridge National Laboratory is widely used and accepted around the world for criticality safety analyses. The well-known KENO V.a three-dimensional Monte Carlo criticality computer code is one of the primary criticality safety analysis tools in SCALE. The KENO V.a primer is designed to help a new user understand and use the SCALE/KENO V.a Monte Carlo code for nuclear criticality safety analyses. It assumes that the user has a college education in a technical field. There is no assumption of familiarity with Monte Carlo codes in general or with SCALE/KENO V.a in particular. The primer is designed to teach by example, with each example illustrating two or three features of SCALE/KENO V.a that are useful in criticality analyses. The primer is based on SCALE 6.2 and 6.3, which includes the Fulcrum graphical user interface (GUI). Each example uses Fulcrum to provide the framework for preparing input data and viewing output results. Starting with a Quickstart section, the primer gives an overview of the basic requirements for SCALE/KENO V.a input and allows the user to quickly run a simple criticality problem with SCALE/KENO V.a. The sections that follow Quickstart include a list of basic objectives at the beginning that identifies the goal of the section and the individual SCALE/KENO V.a features that are covered in detail in the sample problems in that section. Upon completion of the primer, a new user should be comfortable using Fulcrum to set up criticality problems in SCALE/KENO V.a. The primer provides a starting point for the criticality safety analyst who uses SCALE/KENO V.a. Complete descriptions are provided in the SCALE/KENO V.a manual. Although the primer is self-contained, it is intended as a companion volume to the SCALE/KENO V.a training and documentation. The SCALE manual and training schedule are available at https://scale.ornl.gov. The primer provides specific examples of using SCALE/KENO V.a for criticality analyses; the SCALE/KENO V.a manual provides information on the use of SCALE/KENO V.a and all its modules. The primer also contains an appendix with sample input files. In addition, this primer, its errata and sample inputs are also available at https://code.ornl.gov/scale/primers/kenova.

98 NUCLEAR DISARMAMENT, SAFEGUARDS, AND PHYSICAL P↗

Updated Primers Generated for SCALE 6.2 for KENO V.a and KENO-VI

Primers were developed and published for the use of the KENO V.a and KENO-VI codes in 2005 and 2008, respectively. These primers were both developed for SCALE 5 using the GeeWiz graphical user interface (GUI). Many new capabilities have been added to the transport codes since the release of these primers. The GUI was also changed to Fulcrum with the release of SCALE 6.2. For these reasons, updated versions of both primers were developed for a planned released in September 2020. The KENO V.a and KENO-VI codes are almost always run within the associated CSAS5 and CSAS6 sequences within SCALE, so the primers use the sequences and do not address running the codes in stand-alone mode.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Updated Primers Generated for SCALE 6.2 for KENO V.a and KENO-VI [Slides]

Primers were developed and published for the use of the KENO V.a and KENO-VI codes in 2005 and 2008, respectively. These primers were both developed for SCALE 5 using the GeeWiz graphical user interface (GUI). Many new capabilities have been added to the transport codes since the release of these primers. The GUI was also changed to Fulcrum with the release of SCALE 6.2. For these reasons, updated versions of both primers were developed for a planned released in September 2020. The KENO V.a and KENO-VI codes are almost always run within the associated CSAS5 and CSAS6 sequences within SCALE, so the primers use the sequences and do not address running the codes in stand-alone mode.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Sulfur Pellets Responses to a Bare and Steel Reflected Pulse of the Oak Ridge National Laboratory Health Physics Research Reactor

The experiments analyzed in this report were conducted at the Health Physics Research Reactor (HPRR), also known as the $\textit{Fast Burst Reactor}$. The reactor was designed and built at Oak Ridge National Laboratory (ORNL) in 1961. The HPRR was an unmoderated, unshielded fast reactor that used highly enriched uranium and molybdenum alloy as fuel. The reactor was initially sent to the Nevada Test Site in 1962, where it was used to evaluate radiation doses received as a result of the Hiroshima and Nagasaki bombings during World War II. A few years later, the reactor was sent back to ORNL to be part of the Dosimetry Application Research (DOSAR) facility shown in Figure 1, which included a reactor building shown on the left (west) of the picture and a control and laboratory building in the upper right corner (northeast). The critical assembly was used for numerous technical studies, including systems calibration, dosimetry, radiobiology of plants and animals, testing of radiation alarms, as well as teaching and training in radiation dosimetry and nuclear engineering. Between 1963 and 1987, the HPRR was operated for thousands of hours, achieving criticality close to 10,000 times and motivating many publications. The HPRR was decommissioned in 1987. The goal of this effort was to use historical data from operation of the HPRR to create a criticality accident alarm system (CAAS) benchmark to be included in the $\textit{International Handbook of Evaluated Criticality Safety Benchmark Experiments}$ (ICSBEP Handbook). A thorough inspection was performed of all available documentation and information available. The most promising experiments that were selected for evaluation were those described in the 1987 ORNL report entitled $\textit{Health Physics Research Reactor Reference Dosimetry}$, ORNL-6240. The report includes reference dosimetry results of the shielded and unshielded configurations of the HPRR after burst operations. Because of changes to the reactor positioning and storage systems that were made in 1985, the previous dosimetry reports became obsolete, and the newly designed experiments were needed to create the HPRR’s adjusted dosimetry data. The various results reported in ORNL-6240 include reference doses and dose equivalents from different conventions at different distances and elevations as determined using the detected neutron fluence and conversion factors. The HPRR neutron fluence was obtained through different methods, including sulfur pellet analysis and threshold detector unit data. Information about the HPRR spectrum was also obtained through Bonner sphere measurements. This benchmark is focused on a part of the measured sulfur fluences reported in Appendix H of ORNL-6240. Standard commercial sulfur pellets were placed at different distances from the HPRR centerline during burst operation and were activated due to the 32 S(n,p) 32 P reaction. The resulting 32 P activity was then measured and the information about the corresponding sulfur fluence and/or neutron dose could be extracted. Many of those measurements have 7 been performed with the HPRR in its bare configuration or with different shields (combinations of Lucite, concrete, steel). All the necessary, precise information about material and/or dimensions of the different shields was not found, so it was decided to focus only on the unshielded and steel-shielded configurations to minimize the benchmark uncertainty. A total of 31 cases (24 unshielded and 7 shielded cases at different positions) of sulfur fluence were selected before evaluation to develop the benchmark.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗