Overview of SAVY-4000 Lifetime Extension Activities in Fiscal Year 2024

This report provides an overview of activities engaged in during the 2024 fiscal year in support of the SAVY-4000 (hereafter “SAVY”) lifetime extension. As the final full year prior to the submittal of the technical basis, efforts were made to assess the current understanding regarding SAVY degradation in service as well as any knowledge that provided a more substantive view of the challenges that SAVYs face in storage. Close coordination with the stakeholders (i.e. LANL program office) ensured alignment with expectations regarding timelines for the remainder of the activities supporting the technical basis document for the lifetime extension request.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Corrosion Analysis of 121103072 (SAVY-4000)

A surveillance feedlist for fiscal year (FY) 2022 was developed with the intent to target containers with contents known to generate corrosive gasses. One SAVY-4000 (hereafter “SAVY”) container with a serial number 121103072 was selected due to the reasonable wattage and known molten salt extraction (MSE) material corrosive behavior. The material was measured at 3.08 W with approximately 200 g of material placed inside of the SAVY for 6.07 years. The inner packaging configuration included a ¼ Qt stainless steel slip top inner container and a sPVC bag-out bag enclosing the inner container. Visual observations of the container during retrieval revealed several concerning features on the exterior of the container, notably on the lid. Fig. 1 shows the container lid along with an inset image further magnifying the features of interest. The corroded tamper indicating device (TID) wire and the corroded radioactive material tag wire indicated that corrosive gas species for steel were produced during storage. Although the TID wire and rad tag wire are not the same composition as the SAVY body and lid, these are often used as an indicator of potential corrosion inside of the SAVY container. The oxide residing inside of the filter holes and significant buildup around one hole provided further evidence supporting the presence of corrosive species inside of the container.

36 MATERIALS SCIENCE↗

Hyperspectral Detection of the Fluorescence Shift between Chirality-Sorted Empty and Water-Filled Single-Wall Carbon Nanotube Enantiomers

Single-wall carbon nanotubes (SWCNTs) have extraordinary electronic and optical properties that depend strongly on their exact chiral structure and their interaction with their inner and outer environment. The fluorescence (PL) of semiconducting SWCNTs, for instance, will shift depending on the molecules with which the SWCNT’s hollow core is filled. These interaction-induced shifts are challenging to resolve on the ensemble level in samples containing a mixture of different filling contents due to the relatively large inhomogeneous line width of the ensemble SWCNT PL compared to the size of these shifts. To circumvent this inhomogeneous broadening, single-tube spectroscopy and hyperspectral imaging are often applied, which until now required time-consuming statistical studies. Here, we present hyperspectral PL microscopy combined with automated SWCNT segmenting based on either principal component analysis or a convolutional neural network, capable of both spatially and spectrally resolving the PL along the length of many individual SWCNTs at the same time and automatically fitting peak positions and line widths of individual SWCNTs. The methodology is demonstrated by accurately determining the emission shifts and line widths of thousands of left- and right-handed empty and water-filled SWCNTs coated with a chiral surfactant, resulting in four statistical distributions which cannot be resolved in ensemble spectroscopy of unsorted samples. The results demonstrate a robust method to quickly probe ensemble properties with single-enantiomer spectral resolution. Moreover, it promises to be an absolute quantitative method to characterize the relative abundances of SWCNTs with different handedness or filling content in macroscopic samples, simply by counting individual species.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

3013 Fire Test 2020: Post-Test Measurements and Analysis

Sandia National Laboratory conducted fire tests on ten 3013 containers with varying amounts of water. The containers with attached manifolds were sent to Los Alamos National Laboratory for post-test measurements of the plastic deformation, the amount of water remaining on the material post-test and the mass loss. The measurements of the plastic deformation were used to determine the free gas volume in each container and manifold post-test. The disassembly of each container was documented by photographs. The amount of pre-test gas constituents is also reported using data in the Sandia Final Report.

3013 fire test↗

3013 Fire Test 2020: Post-Test Volumes

Sandia National Laboratory conducted fire tests on ten 3013 containers with varying amounts of water. The containers plastically deformed during the fire tests. The plastic deformation increased the free-gas volume within the containers. The amount of plastic deformation is measured and post-test free gas volumes at 25°C is reported.

36 MATERIALS SCIENCE↗

Focused Ion Beam analysis of non radioactive samples [PowerPoint]

The presentation includes various images to illustrate the analysis. Helios G4 Plasma FIB: Xe ion columns mills material 30 times faster than Ga; Options include: Energy Dispersive Spectroscopy (EDS), Wavelength Dispersive spectroscopy (WDS) Electron backscattered Diffraction (EBSD), Time of Flight Sims (ToF SIMS), Inert gas/vacuum sample transfer system; Excels at micromachining and collecting 3D datasets using various detection systems.

42 ENGINEERING↗

Surveillance Report on SAVY 4000 and Hagan Nuclear Material Storage Containers Update for FY2020

A Surveillance Program is in place to assess how nuclear material storage containers at LANL are aging in-service. This program is guided by the LANL Surveillance Plan which is required by DOE M441.1-1. The plan is modified as necessary to ensure that any issues identified during surveillance or laboratory studies are examined in future surveillances, and that any lifetime implications are taken into account. Under the plan, overall container integrity is evaluated by a combination of visual inspections and photographs. Multiple measurements are made to assess the SAVY 4000 performance, including, helium leakage rate, O-ring hardness (durometer), O-ring compression set, filter performance and filter water resistance. The containers for surveillance are chosen annually based on the previous surveillance program results and observations. The surveillance plan targets items believed to provide the greatest challenge to the SAVY 4000 container integrity.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

SAVY-4000 Corrosion Evaluation Plan

Nuclear material packages, with few exceptions, outside of an approved engineered contamination barrier must meet packaging, surveillance, and testing requirements designed to protect workers from airborne contamination per Department of Energy (DOE) Manual 441.1-1, Nuclear Material Packaging. The SAVY-4000 containers were developed at Los Alamos National Laboratory (LANL) in conjunction with Nuclear Filter Technology Inc. (NFT Inc.) as a general purpose vented manually-compliant container system for staging and storage of plutonium for LANL and the DOE complex. The SAVY-4000 containers have a 316L stainless steel containment barrier, which was selected based on its corrosion resistant properties. These containers were approved for use in 2014 with a five-year design life; LANL requested and DOE has approved lifetime extension from 5 to 15 years. The 10-year lifetime extension was proposed as a conservative recommendation based on the corrosion observations for the metal components in surveillance and results from laboratory studies. Extensive accelerated aging studies have been done on the SAVY-4000 O-ring with very little evidence of significant degradation when subjected to aggressive elevated temperature and radiation conditions. Therefore, our current conservative lifetime estimate for the O-ring and the filter is 40 years at 80°C. Additional work is ongoing in a phased approach to further extend the design life of the Manual compliant SAVY-4000 storage container; the limiting component for further life extension is still the 316L containment barrier.

36 MATERIALS SCIENCE↗

Aerobijels: Ultralight Carbon Monoliths from Cocontinuous Emulsions

In this work, bijels are used to develop a new class of ultralight hierarchically porous aerogels exhibiting multimodal porosity across multiple length scales. Through in situ functionalization of a particle-laden liquid interface wherein binary liquid pairs are kinetically trapped out of equilibrium through interfacial jamming, monolithic and freestanding carbon electrodes are produced with prescribed bulk densities down to ≈2 mg cm -3 . Exemplary electrokinetic experiments indicate that the bicontinuity of the pore structure is essential for enhancing transport to and from the active electrode surfaces, demonstrating that these materials possess a superior ability to accumulate and transport charge when compared to analogous systems with restricted pore connectivity and fluid throughput. This approach offers a new synthetic route to bicontinuous and hierarchical aerogel materials with nested multimodal porosities. Furthermore, the flexibility of this scheme can address critical issues related to transport-limited behaviors that arise in many technological fields, ranging from energy and catalysis research to remediation and sensing applications.

36 MATERIALS SCIENCE↗

Evaluating Corrosion Effects on the Stainless Steel Components of the SAVY-4000/Hagan Nuclear Material Storage Containers: FY19 Update

This report provides an update of the FY19 corrosion observations, laboratory studies, and mitigation efforts for the nuclear material storage program at Los Alamos National Laboratory. Nuclear material packages outside of an approved engineered contamination barrier must meet packaging, surveillance, and testing requirements designed to protect workers from airborne contamination per Department of Energy (DOE) Manual 441.1-1, Nuclear Material Packaging.1 The SAVY-4000 containers were developed at Los Alamos National Laboratory (LANL) in conjunction with Nuclear Filter Technology as a manually-compliant container system for staging and storage of plutonium for LANL and the DOE complex.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Resonance Raman signature of intertube excitons in compositionally-defined carbon nanotube bundles

Electronic interactions in low-dimensional nanomaterial heterostructures can lead to novel optical responses arising from exciton delocalization over the constituent materials. Similar phenomena have been suggested to arise between closely interacting semiconducting carbon nanotubes of identical structure. Such behavior in carbon nanotubes has potential to generate new exciton physics, impact exciton transport mechanisms in nanotube networks, and place nanotubes as one-dimensional models for such behaviors in systems of higher dimensionality. Here we use resonance Raman spectroscopy to probe intertube interactions in (6,5) chirality-enriched bundles. Raman excitation profiles for the radial breathing mode and G-mode display a previously unobserved sharp resonance feature. We show the feature is evidence for creation of intertube excitons and is identified as a Fano resonance arising from the interaction between intratube and intertube excitons. The universality of the model suggests that similar Raman excitation profile features may be observed for interlayer exciton resonances in 2D multilayered systems.