Engineering topics
Durbin, Samuel
Publications and source records attributed to Durbin, Samuel.
Thermal-Hydraulic Investigations of a Horizontal Dry Cask Simulator.
Abstract not provided.
Measurement of Through-Wall Aerosol Transmission for SCC-Like Geometries.
Abstract not provided.
Measurement of Through-Wall Aerosol Transmission for SCC-Like Geometries.
Abstract not provided.
Development of Mockups and Instrumentation for Spent Fuel Drying Tests
The purpose of this report is to provide updates on the experimental components, methodology, and instrumentation under development for use in advanced studies of realistic drying operations conducted on surrogate spent nuclear fuel. Validation of the extent of water removal in a dry spent nuclear fuel storage system based on drying procedures used at nuclear power plants is needed to close existing technical gaps. Operational conditions leading to incomplete drying may have potential impacts on the fuel, cladding, and other components in the system. Water remaining in canisters upon completion of drying procedures can lead to cladding corrosion, embrittlement, and breaching, as well as fuel degradation. Additional information is needed on the drying process efficacy to help evaluate the potential impacts of water retention on extended longterm dry storage. A general lack of data suitable for model validation of commercial nuclear canister drying processes necessitates additional, well-designed investigations. Smaller-scale tests that incorporate relevant physics and well-controlled boundary conditions are essential to provide insight and guidance to the simulation of prototypic systems undergoing drying processes. This report describes the implementation of moisture monitoring equipment on a pressurized, submersible system employing a single waterproof, electrically heated spent fuel rod simulator as a demonstration of analytical capabilities during a drying process. A mass spectrometer with specially designed inlets was used to monitor moisture and other gases at 150 kPa to 800 kPa for a test simulating a forced helium dehydration procedure and below 1 torr for tests mimicking a vacuum drying process. The dew point data from the mass spectrometer was found to be in good agreement with a solid-state moisture probe. A distinct advantage of the mass spectrometer system was the capability to directly sample from the hightemperature (>200 °C) head space expected in a prototypic scale experiment where a solid-state moisture probe would suffer considerable loss of accuracy or fail altogether. The operational and analytical experiences gained from this test series are poised to support an expansion to assembly-scale tests at prototypic length. These assemblies are designed to feature prototypic assembly hardware, advanced diagnostics for in situ internal rod pressure monitoring, and failed fuel rod simulators with engineered cladding defects to challenge the drying system with waterlogged fuel.
Thermal-Hydraulic Investigations of a Horizontal Dry Cask Simulator.
Abstract not provided.
Analysis of water retention in isothermal vacuum drying test.
Abstract not provided.
Horizontal Dry Cask Simulator Testing and Applications to Blind Model Validation.
Abstract not provided.
Characterization of Through-Wall Aerosol Transmission for SCC-Like Geometries.
Abstract not provided.
Horizontal Dry Cask Simulator Testing and Applications to Blind Model Validation.
Abstract not provided.
Update on the Thermal Hydraulic Investigations of a Horizontal Dry Cask Simulator
The thermal performance of commercial spent nuclear fuel dry storage casks is evaluated through detailed numerical analysis. These modeling efforts are completed by the vendor to demonstrate performance and regulatory compliance. The calculations are then independently verified by the Nuclear Regulatory Commission (NRC). Canistered dry storage cask systems rely on ventilation between the inner canister and the overpack to convect heat away from the canister to the surrounding environment for both horizontal and vertical configurations. Recent advances in dry storage cask designs have significantly increased the maximum thermal load allowed in a canister in part by increasing the efficiency of internal conduction pathways and by increasing the internal convection through greater canister helium pressure. Carefully measured data sets generated from testing of full-sized casks or smaller cask analogs are widely recognized as vital for validating these models. While several testing programs have been previously conducted, these earlier validation studies did not integrate all the physics or components important in a modern, horizontal dry cask system. The purpose of the present investigation is to produce data sets that can be used to benchmark the codes and best practices presently used to determine cladding temperatures and induced cooling air flows in modern horizontal dry storage systems. The horizontal dry cask simulator (HDCS) has been designed to generate this benchmark data and add to the existing knowledge base. The objective of the HDCS investigation is to capture the dominant physics of a commercial dry storage system in a well-characterized test apparatus for any given set of operational parameters. The close coupling between the thermal response of the canister system and the resulting induced cooling air flow rate is of particular importance.
SNL Contribution: Consequence Analysis for Moisture Remaining in Dry Storage Canisters After Drying
This report discusses several possible sources of water that could persist in SNF dry storage canisters through the drying cycle. In some cases, the water is trapped in occluded geometries in the cask such as dashpots or damaged fuel. Persistence of water or ice in such locations seems unlikely, given the high heat load of the canistered fuel; this is especially true in the case of vacuum drying, where a strong driver exists to remove water vapor from the headspace of such occluded geometries. Water retention in Boral® core material is a known problem, that has in the past resulted in the need for much extended drying times. Since the shift to slightly higher porosity "blister resistant" Boral®, water drainage appears to be less of a problem. However, high surface areas for the Boral® core material will provide a trap for significant amounts of adsorbed water, at least some of which is certain to survive the drying process. Moreover, if corrosion within the cores produces hydrous aluminum corrosion products, these may also survive.
Dry Cask Simulator - Model Validation and Application to Horizontal Dry Cask Storage Systems.
Abstract not provided.