Search NASA⌕ Search

Engineering topics

Easley, Mitchell

Publications and source records attributed to Easley, Mitchell.

Resonance Suppression based on Predictive Control of Grid-following Inverters with LCL Filter in Weak Grid Condition

This paper presents an effective resonance suppression control when grid interactive inverter with LCL filter experience weak grid conditions. The resonance suppression mechanism is based on finite-set model predictive control (FSMPC) with adaptive cost function to alter the controller objectives seamlessly. The large parasitic impedance and low short circuit ratio (SCR) of weak grid challenges the operation of gridconnected inverters. Specifically, the LCL filter resonance may get excited, resulting in collapse of the inverter operation. To address this issue, an effective active damping approach is implemented in the proposed control. In the proposed active damping scheme for resonance suppression, the feedback currents are switched based on the operating conditions of inverter. During the stiff grid conditions, grid current serves as feedback to the controller. While in the weak grid conditions, the inverter current is selected as feedback signal. The toggling action between these two feedback currents is determined by comparing moving RMS of grid current with threshold current as constraint in the cost function of the proposed MPC scheme. The threshold current for toggling action is based on the reference active and reactive power setpoints plus an acceptable band of variation. The theoretical analysis is verified by several case studies.

Umar, Muhammad Farooq↗

Decoupled Active and Reactive Power Control without PLL Requirement for Differential Buck Converter

This paper presents a decoupled active and reactive power control for the differential buck converter. This control does not require phase locked loop (PLL) for synchronization. Also, it achieves active and reactive power control in a simple single control loop structure. The differential buck converter has the capability to compensate the double line frequency power ripple without relying on additional hardware. Particularly, the Common Mode (CM) operation is used for active double line frequency power ripple absorption. Whereas, the Differential Mode (DM) operation is used as an active and reactive power exchanging port between the converter and the grid at the point of common coupling (PCC). The motivation behind this paper proposal are: (i) to avoid PLL induced instabilities, especially, when connecting the differential buck converter with weak grid, and (ii) direct active and reactive power control for the differential buck in a single loop control. The theoretical analyses are verified with a 5 kW converter with only 50 μF decoupling capacitor connected to a weak grid.

Khan, Ahmad↗