A Rolling Element Tribometer for the Study of Liquid Lubricants in Vacuum

A tribometer for the evaluation of liquid lubricants in vacuum is described. This tribometer is essentially a thrust bearing with three balls and flat races having contact stresses and ball motions similar to those in an angular contact ball bearing operating in the boundary lubrication regime. The friction coefficient, lubrication lifetime, and species evolved from the liquid lubricant by tribodegradation can be determined. A complete analysis of the contact stresses and energy dissipation together with experimental evidence supporting the analysis are presented.

Pepper, Stephen V.↗

High-Temperature/Vacuum Fiber-Pushout Apparatus

Fiber-pushout tests performed at temperatures up to 1,100 degrees C. Apparatus performs fiber-pushout tests using radiant heating in vacuum. Vacuum maintained by turbopump prevents significant specimen oxidation during test. Successfully applied to metal and ceramic matrix composites being developed for jet engines. Applicable to many industrial applications, such as automotive components and energy-conversion devices. Previous Brief, "New Testing Tool for Composite Interfaces" (LEW-15297), describes apparatus designed to perform fiber-pushout testing at room temperature.

Eldridge, Jeffrey I.↗

Apparatus for performing high-temperature fiber push-out testing

The apparatus disclosed in the present invention measures the force at which a fiber resist the motion of an indenter driven at constant speed. This apparatus conducts these test in a vacuum of about 10(exp -6) tort and at temperatures up to 1100 C. Temperature and vacuum environment are maintained while controlling indenter motion, sample position, and providing magnified visual inspection during the test.

Eldridge, Jeffrey I.↗

Cryogenic probe station for use in automated microwave and noise figure measurements

A cryogenic measurement system capable of performing on-wafer RF testing of semiconductor devices and circuits has been developed. This 'CryoProbe Station' can wafer-probe devices and circuits at cryogenic temperatures, thus eliminating the need for wire bonds. The system operates under vacuum created by a sorption pump. It uses an open cycle cooling system that can be cooled with either liquid nitrogen or liquid helium. Presently, it can reach temperatures, as low as 80 K and 37 K for each of the coolants, respectively. The temperature can be raised using a heater and it is stabilized to within 0.2 K by use of a temperature controller. The CryoProbe Station features a 1 by 2 inch stage that can hold large circuits and calibration standards simultaneously. The system is used with a Hewlett Packard 8510C Automatic Network Analyzer (ANA) to obtain S-parameter data over the frequency range 0.045-26.5 GHz. S-parameter data on HEMT (high electron mobility transistors) devices has been obtained with this station. With the use of DEEMBED software from NIST, detailed transmission line studies have been performed. Although the CryoProbe Station is designed for frequencies up to 26.5 GHz, useful transmission line data has been obtained for frequencies as high as 40 GHz. The CryoProbe station has also been used with the ATN noise figure measurement system to perform automatic, temperature dependent noise figure measurements.

Taub, Susan R.↗

Low-current traveling wave tube for use in the microwave power module

The results of a traveling-wave-tube/multistage depressed-collector (TWT-MDC) design study in support of the Advanced Research Projects Agency/Department of Defense (ARPA/DOD) Microwave Power Module (MPM) Program are described. The study stressed the possible application of dynamic and other tapers to the RF output circuit of the MPM traveling wave tube as a means of increasing the RF and overall efficiencies and reducing the required beam current (perveance). The results indicate that a highly efficient, modified dynamic velocity taper (DVT) circuit can be designed for the broadband MPM application. The combination of reduced cathode current (lower perveance) and increased RF efficiency leads to (1) a substantially higher overall efficiency and reduction in the prime power to the MPM, and (2) substantially reduced levels of MDC and MPM heat dissipation, which simplify the cooling problems. However, the selected TWT circuit parameters need to be validated by cold test measurements on actual circuits.

Palmer, Raymond W.↗

Interim report on the analysis of the microwave power module

The results of a traveling wave tube multistage depressed collector (TWT-MDC) design study in support of the DARPA/DoD Microwave Power Module (MPM) Program are described. The study stressed the MDC as a key element in obtaining the required high overall efficiencies in the MPM application. The results showed that an efficient MDC, utilizing conventional design and fabrication techniques can be designed for the first generation MPM TWT, which permits a package one wavelength thick (.66 in. at 18 GHz). The overall TWT efficiency goal of 40 percent for electronic countermeasure (ECM) applications appears to be readily achievable. However, the 50 percent goal for radar applications presents a considerable challenge.

Ramins, Peter↗

Measurements of complex permittivity of microwave substrates in the 20 to 300 K temperature range from 26.5 to 40.0 GHz

A knowledge of the dielectric properties of microwve substrates at low temperatures is useful in the design of superconducting microwave circuits. Results are reported for a study of the complex permittivity of sapphire (Al2O3), magnesium oxide (MgO), silicon oxide (SiO2), lanthanum aluminate (LaAlO3), and zirconium oxide (ZrO2), in the 20 to 300 Kelvin temperature range, at frequencies from 26.5 to 40.0 GHz. The values of the real and imaginary parts of the complex permittivity were obtained from the scattering parameters, which were measured using an HP-8510 automatic network analyzer. For these measurements, the samples were mounted on the cold head of a helium gas closed cycle refrigerator, in a specially designated vacuum chamber. An arrangement of wave guides, with mica windows, was used to connect the cooling system to the network analyzer. A decrease in the value of the real part of the complex permittivity of these substrates, with decreasing temperature, was observed. For MgO and Al2O3, the decrease from room temperature to 20 K was of 7 and 15 percent, respectively. For LaAlO3, it decreased by 14 percent, for ZrO2 by 15 percent, and for SiO2 by 2 percent, in the above mentioned temperature range.

Miranda, Felix A.↗

Measurements of complex permittivity of microwave substrates in the 20 to 300 K temperature range from 26.5 to 40.0 GHz

A knowledge of the dielectric properties of microwave substrates at low temperatures is useful in the design of superconducting microwave circuits. Results are reported for a study of the complex permittivity of sapphire (Al2O3), magnesium oxide (MgO), silicon oxide (SiO2), lanthanum aluminate (LaAlO3), and zirconium oxide (ZrO2), in the 20 to 300 Kelvin temperature range, at frequencies from 26.5 to 40.0 GHz. The values of the real and imaginary parts of the complex permittivity were obtained from the scattering parameters, which were measured using a HP-8510 automatic network analyzer. For these measurements, the samples were mounted on the cold head of a helium gas closed cycle refrigerator, in a specially designed vacuum chamber. An arrangement of wave guides, with mica windows, was used to connect the cooling system to the network analyzer. A decrease in the value of the real part of the complex permittivity of these substrates, with decreasing temperature, was observed. For MgO and Al2O3, the decrease from room temperature to 20 K was of 7 and 15 percent, respectively. For LaAlO3, it decreased by 14 percent, for ZrO2 by 15 percent, and for SiO2 by 2 percent, in the above mentioned temperature range.

Miranda, Felix A.↗

Isotropic graphite multistage depressed collectors - A progress report

A small isotropic-graphite-electrode multistage depressed collector (MDC) was designed, fabricated, and evaluated in conjunction with a 500-W CW 4.8-9.6-GHz TWT. The carbon electrode surfaces were used to improve the TWT overall efficiency by minimizing the secondary-electron emission losses in the MDC. The design and fabrication of the brazed graphite MDC assembly are described. The TWT and graphite-electrode MDC bakeout and processing (outgassing) characteristics were evaluated and found to be comparable to those for TWTs equipped with copper-electrode MDCs. The TWT and MDC performance was optimized for broadband CW operation at saturation. The average RF, overall, and MDC efficiencies were 14.9, 46.4, and 83.6 percent, respectively, across the octave operating band. A 1500-h CW test showed no gas buildup and excellent stability of the electrode surfaces.

Ramins, Peter↗

Performance of a multistage depressed collector with machined titanium electrodes

The performance of a multistage depressed collector (MDC) with machined titanium electrodes was evaluated in conjunction with an 800-W, 8- to 18-GHz travelling-wave tube (TWT) and was compared with the performances of geometrically identical copper and isotropic graphite electrode MDC's operated with the same TWT. The titanium electrode MDC produced a modest (about 3 percent) improvement in the MDC and the TWT overall efficiencies as compared with the copper electrode MDC, but its performance was substantially lower than that of the isotropic graphite electrode MDC.

Ramins, Peter↗

Carbon Coating Of Copper By Arc-Discharge Pyrolysis

Adherent, abrasion-resistant coat deposited with existing equipment. Carbon formed and deposited as coating on copper substrate by pyrolysis of hydrocarbon oil in electrical-arc discharges. Technique for producing carbon deposits on copper accomplished with electrical-discharge-machining equipment used for cutting metals. Applications for new coating technique include the following: solar-energy-collecting devices, coating of metals other than copper with carbon, and carburization of metal surfaces.

Ebihara, Ben T.↗

Performance of a small, graphite electrode, multistage depressed collector with a 500-W, continuous wave, 4.8- to 9.6-GHz traveling wave tube

A small, isotropic graphite multistage depressed collector (MDC) and a short permanent magnet refocuser were designed, fabricated, and evaluated in conjunction with a 500-W, continuous-wave (CW), 4.8 to 9.6 GHz traveling wave tube (TWT). A novel performance optimization system and technique were used to optimize the TWT-MDC performance for saturated broad-band operation. The MDC performance was evaluated in both four- and three-stage configurations. Average TWT overall and four-stage collector efficiencies of 43.8 and 82.6 percent, respectively, were obtained for saturated octave-bandwidth operation. The isotropic graphite electrode material performed well, and shows considerable promise. However, considerably more test experience is required before definitive conclusions on its suitability for space and airborne TWT's can be made.

Ramins, Peter↗

Traveling-wave-tube efficiency improvement by a low-cost technique for deposition of carbon on multistage depressed collector

A simple method of improving the traveling-wave-tube (TWT) and multistage depressed collector (MDC) efficiency has been demonstrated. The efficiency improvement was produced by the application of a thin layer of carbon to the copper electrodes of the MDC by means of a rapid, low-cost technique involving the pyrolysis of hydrocarbon oil in electric arc discharges. Experimental results with a representative TWT and MDC showed an 11 percent improvement in both the TWT and MDC efficiencies as compared to those of the same TWT and MDC efficiencies with bare copper electrode surfaces. An extended test with a 500-W, continuous wave (CW) TWT and small-sized MDC indicated good stability of the carbon coated electrode surfaces after a relatively small initial degradation in TWT overall and apparent MDC efficiencies.

Ebihara, Ben T.↗

Design, fabrication and performance of small, graphite electrode, multistage depressed collectors with 200-W, CW, 8- to 18-GHz traveling-wave tubes

Small multistage depressed collectors (MDC's) which used pyrolytic graphite, ion-beam-textured pyrolytic graphite, and isotropic graphite electrodes were designed, fabricated, and evaluated in conjuntion with 200-W, continuous wave (CW), 8- to 18-GHz traveling-wave tubes (TWT's). The design, construction, and performance of the MDC's are described. The bakeout performance of the collectors, in terms of gas evolution, was indistinguishable from that of typical production tubes with copper collectors. However, preliminary results indicate that some additional radiofrequency (RF) and dc beam processing time (and/or longer or higher temperature bakeouts) may be needed beyond that of typical copper electrode collectors. This is particularly true for pyrolytic graphite electrodes and for TWT's without appendage ion pumps. Extended testing indicated good long-term stability of the textured pyrolytic graphite and isotropic graphite electrode surfaces. The isotropic graphite in particular showed considerable promise as an MDC electrode material because of its high purity, low cost, simple construction, potential for very compact overall size, and relatively low secondary electron emission yield characteristics in the as-machined state. However, considerably more testing experience is required before definitive conclusions on its suitability for electronic countermeasure systems and space TWT's can be made.

Ebihara, Ben T.↗

TWT efficiency improvement by a low-cost technique for deposition of carbon on MDC electrodes

A simple method of improving the TWT and multistage depressed collector (MDC) efficiency has been demonstrated. The efficiency improvement was produced by the application of a thin layer of carbon to the copper electrodes of the MDC by means of a rapid low-cost technique involving the pyrolysis of hydrocarbon oil in electric arc discharges. Experimental results with a representative TWT and MDC showed an 11 percent improvement in both the TWT and MDC efficiencies as compared to those of the same TWT and MDC with machined copper electrode surfaces. An extended test with a 550-W CW TWT indicated good durability of the carbon-coated electrode surfaces.

Ebihara, Ben T.↗

Improvements in MDC and TWT overall efficiency through the application of carbon electrode surfaces

The effects of secondary electron emission losses on TWT efficiency are investigated and techniques for minimizing these losses are described. The TWT-multistage depressed collector performance was optimized and measured over a wide range of operating conditions using geometrically identical collectors that utilized copper, pyrolytic graphite, and isotropic graphite electrodes. The data reveal that carbon rather than copper electrodes improve the TWT efficiency, and the ion-textured graphite is most effective in minimizing the secondary electron emission losses. It is noted that degradation of the collector efficiency can be limited to a small percentage with the proper MDC design and the use of low secondary electron yield carbon electrode surfaces.

Ramins, Peter↗