Search NASA⌕ Search

Engineering topics

Economou, T. E.

Publications and source records attributed to Economou, T. E..

At least 19 records

Streaming Clumps Ejection Model and the Heterogeneous Inner Coma of Comet Wild 2

The conventional concept of cometary comae is that they are dominated by fine particulates released individually by sublimation of surface volatiles and subsequent entrainment in the near-surface gas. It has long been recognized that such particulates could be relatively large, with early estimates that objects perhaps up to one meter in size may be levitated from the surface of the typical cometary nucleus. However, the general uniformity and small average particulate size of observed comae and the relatively smooth, monotonic increases and decreases in particle density during the Giotto flythrough of comet Halley s coma in 1986 reinforced the view that the bulk of the particles are released at the surface, are fine-sized and inert. Jets have been interpreted as geometrically constrained release of these particulates. With major heterogeneities observed during the recent flythrough of the inner coma of comet Wild 2, these views deserve reconsideration.

Clark, B. C.↗

An Alpha-p-x Analytical Instrument for Lunar Resource Investigations

An instrument using alpha backscattering, alpha-proton nuclear reactions, and x-ray production by alpha particles and other auxiliary sources can be used on lunar landers to provide detailed analytical information concerning the lunar surface material. This information is important scientifically and can be the basis for utilizing efficiently lunar resources to build lunar colonies in the future. This alpha particle instrument uses radioactive isotopes, silicon detectors for the alpha and proton modes, and mercuric iodide detectors operating at room temperature for the x-ray mode. The alpha and proton modes of the instrument can provide an analysis for all elements (except hydrogen) present in amounts greater than about 1 percent by atom. These modes have excellent sensitivity and accuracy for the lighter elements, in particular, directly determining the amount of oxygen in the lunar soil. This is an element of paramount significance for the lunar resource mission. The x-ray mode makes possible a determination of Ti, Fe, and other important metals with even greater accuracy. In general, the x-ray mode provides increased sensitivity for heavier elements, in many cases achieving a sensitivity of several hundred ppm.

Economou, T. E.↗

Use of mercuric iodide X-ray detectors with alpha backscattering spectrometers for space applications

The authors present X-ray fluorescence (XRF) spectra of different extraterrestrial samples taken with a mercuric iodide (HgI2) spectrometer inserted into an alpha backscattering instrument identical to that used in the Soviet Phobos mission. The results obtained with the HgI2 ambient temperature detector are compared with those obtained using an Si(Li) cryogenically cooled detector. Efforts to design an optimized instrument for space application are also described. The results presented indicate that the energy resolution and sensitivity of HgI2 detectors are adequate to meet the performance needs of a number of proposed space applications, particularly those in which cooled silicon X-ray detectors are impractical or even not usable, such as for the target science programs on geoscience opportunities for lunar surface, Mars surface, and other comet and planetary missions being planned by NASA and ESA.

Iwanczyk, J. S.↗

Measurement of the characteristic X ray of oxygen and other ultrasoft X rays using mercuric iodide detectors

This letter reports the detection and resolution of the characteristic X-ray of oxygen at 523 eV and other ultrasoft X-rays (photons energy less than 1 keV) using radiation detectors fabricated from the compound semi-insulator mercuric iodide (HgI2). These detectors are capable of operation at room ambient but in these experiments were slightly cooled using a Peltier element to 0 C. A pulsed light feedback preamplifier with a Peltier element cooled (to -30 deg) first stage field-effect transistor was used to amplify signals from the detector. Overall system noise level was 185 eV (full width at half-maximum) limited by the temperature of the first stage field-effect transistor. With optimal cooling of this element the characteristic X-ray of carbon at 282 eV should be measurable. These results would seem to be important in measurement of biological samples in electron column instruments.

Iwanczyk, J. S.↗

Room-temperature mercuric iodide spectrometry for low-energy X-rays

A discussion of the limits of energy resolution in different energy ranges is given. The energy resolution of a spectrometer is analyzed in terms of the parameters characterizing the crystal, the detector, and the amplification electronics. A high-resolution room-temperature HgI2 spectrometry system was used to measure low-energy X-ray fluorescence spectra. For the MgK-alpha X-ray line the measured resolution was 245 eV (fwhm); the electronic noise linewidth of the system was 225 eV. Alpha-particles were used to excite X-ray fluorescence from low-Z elements separately or in combination. The shape of the photopeaks in the spectra is discussed.

Kusmiss, J. H.↗

Cryogenic particle collection on a cometary mission

The present investigation is concerned with research related to the design of a method for capturing effectively particulate matter and volatiles from the tail of a comet for the purpose of chemical analysis. It is envisaged to conduct a space mission with a means of propulsion which would make it possible to maneuver the space probe into the coma of the comet. The collecting medium has to be chemically inert and easily distinguishable from the particles being collected. It is proposed to employ a film of solid xenon at a temperature of 65 K as the collecting medium. Sublimation of this film and the resultant pressure will be used to concentrate the particles on a small area suitable for analysis. Attention is given to the laboratory apparatus, the experimental work, the experimental results, and the cryogenic requirements for a space mission.

Szara, R. J.↗

Performance of room temperature mercuric iodide /HgI2/ detectors in the ultralow-energy X-ray region

Experiments have been done to study the performance of mercuric iodide (HgI2) detectors in the ultralow-energy X-ray region. Energy resolution values of 245 eV (FWHM) for the Mg K-alpha X-ray line at 1.25 keV and 225 eV (FWHM) for the electronic noise linewidth have been obtained for an HgI2 detector with painted carbon contacts using a pulsed-light feedback preamplifier; the whole system was operated at room temperature. The resolution values in the ultralow-energy region are still limited by electronic noise of the system. In an attempt to minimize X-ray attenuation in the front contact, detectors were prepared with thin evaporated Pd contacts. These detectors show a pronounced low-energy tailing of the photopeak below a few keV, in contrast to the spectra obtained by detectors with carbon contact. An attempt has been made to explain the tailing effect starting with models wich have been proposed to describe similar effects in Ge detectors.

Dabrowski, A. J.↗

An alpha particle instrument with alpha, proton, and X-ray modes for planetary chemical analyses

The interaction of alpha particles with matter is employed in a compact instrument that could provide rather complete in-situ chemical analyses of surfaces and thin atmospheres of extraterrestrial bodies. The instrument is a miniaturized and improved version of the Surveyor lunar instrument. The backscattering of alpha particles and (alpha, p) reactions provide analytical data on the light elements (carbon-iron). An X-ray mode that detects the photons produced by the alpha sources provides sensitivity and resolution for the chemical elements heavier than about silicon. The X-rays are detected by semiconductor detectors having a resolution between 150 and 250 eV at 5.9 keV. Such an instrument can identify and determine with good accuracy 99 percent of the atoms (except hydrogen) in rocks. For many trace elements, the detecting sensitivity is a few ppm. Auxiliary sources could be used to enhance the sensitivities for elements of special interest. The instrument could probably withstand the acceleration involved in semi-hard landings.

Economou, T. E.↗

An alpha particle experiment for chemical analysis of the Martian surface and atmosphere.

An alpha particle experiment similar to the one performed successfully on the Surveyor lunar missions is described. It is designed to provide a chemical analysis of the Martian surface and atmosphere. Analyses of rocks of known and unknown compositions have been made under simulated Martian conditions. The accuracies attained are generally comparable to those of the Surveyor lunar analyses. Improvements have been achieved in determining carbon and oxygen, so that a few per cent of water or carbonates in rocks can be detected. Some aspects of the integration of such an experiment with the spacecraft, a possible mission profile, and some other problems associated with a soft-landing mission to Mars are discussed. The importance of such a chemical analysis experiment in answering current questions about the nature and history of Martian surface material and its suitability for life processes is presented.

Economou, T. E.↗

Examination of returned Surveyor 3 camera visor for alpha radioactivity

The TV camera visor was placed in a vacuum chamber and examined for alpha radioactivity using an alpha-scattering instrument, and plates covered with the same paint and made at the same time as the visor were used as a control. The spectra of visor and plates are very similar, and it is concluded that the gross activity on the visor is due entirely to the activity of the paint. The data were used to obtain the amount of Po-210 activity on the lunar surface. It is felt that the lack of detected alpha radioactivity does not indicate a lack of activity on the moon, since dust layers were knocked off the visor.

Economou, T. E.↗