Search NASA⌕ Search

Engineering topics

Edstrom, S.

Publications and source records attributed to Edstrom, S..

A terahertz pump mega-electron-volt ultrafast electron diffraction probe apparatus at the SLAC Accelerator Structure Test Area facility

Here, we describe a new experimental setup capable of measuring structural dynamics following intense terahertz excitation. This system, developed at the SLAC Accelerator Structure Test Area facility, uses a high-energy ultrafast laser to produce intense terahertz pulses and femtosecond electron bunches that are accelerated to mega-electron-volt kinetic energies. The focused terahertz pulses have electric fields in excess of 600 kV/cm, and the resulting structural dynamics can be followed by electron diffraction. We also present some examples demonstrating its implementation where interactions between the THz pulses and the electron bunch are used to characterize the spatial and temporal characteristics of the THz field.

42 ENGINEERING↗

Single-shot mega-electronvolt ultrafast electron diffraction for structure dynamic studies of warm dense matter

We have developed a single-shot mega-electronvolt ultrafast-electron-diffraction system to measure the structural dynamics of warm dense matter. The electron probe in this system is featured by a kinetic energy of 3.2 MeV and a total charge of 20 fC, with the FWHM pulse duration and spot size at sample of 350 fs and 120 μm respectively. We demonstrate its unique capability by visualizing the atomic structural changes of warm dense gold formed from a laser-excited 35-nm freestanding single-crystal gold foil. The temporal evolution of the Bragg peak intensity and of the liquid signal during solid-liquid phase transition are quantitatively determined. This experimental capability opens up an exciting opportunity to unravel the atomic dynamics of structural phase transitions in warm dense matter regime.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

First Results of the LCLS Laser-Heater System

he very bright electron beam required for an x-ray free electron laser (FEL), such as the LCLS, is susceptible to a microbunching instability in the magnetic bunch compres sors, prior to the FEL undulator. The uncorrelated electron energy spread in the LCLS can be increased by an order of magnitude to provide strong Landau damping against the instability without degrading the FEL performance. To this end, a ‘laser-heater’ system has been installed in the LCLS injector, which modulates the energy of a 135-MeV electron bunch with an IR laser beam in a short undulator, enclosed within a four-dipole chicane. The last half of the chicane time-smears the energy modulation leaving an effective thermal energy spread increase. We present the first commissioning results of this system, its operational issues, its impact on the microbunching instability, and finally its effect on the FEL performance.

43 PARTICLE ACCELERATORS↗

Photon Beamlines and Diagnostics at LCLS

The Linac Coherent Light Source (LCLS) is the first hard-x-ray free electron laser in operation. The turn-on of LCLS was rapid and operation has been reliable. Performance has exceeded the design parameters in several areas. The photon energy output covers a range from 480 eV to over 9 keV; the pulse energy is typically 2-3 mJ, with a maximum of 4 mJ at 2 keV. Electron pulse lengths can be varied from 500 fs to shorter than 10 fs. A low-charge option at 20 pC is being explored, which delivers pulses shorter than 10 fs with a reduced pulse energy, typically around 0.2 mJ. On-demand, single-shot and multi-shot modes up to 60 Hz (planned is 120 Hz) can be made available. The photon diagnostics built for LCLS have been commissioned and provide measurements of various properties of the FEL beam, such as pulse energy, beam size and position, wavelength, and allows for intensity attenuation over the entire wavelength range. The two soft x-ray instruments, the Atomic Molecular and Optics (AMO) and Soft X-ray Material Science (SXR) stations, are fully operational and completed their second user run in mid September 2010. The third user run is scheduled from October to December 2010, and will include the first hard x-ray instrument X-ray Pump-and-Probe (XPP). Three additional hard x-ray stations will follow: CXI (Coherent X-ray Imaging) is planned to start commissioning in December 2010, the XCS (X-ray correlation spectroscopy) instrument will start in June 2011, and the station for Matter in Extreme Conditions (MEC) in 2012. A list of past and future milestones for LCLS commission and operations is shown in table 1. The LCLS hard x-ray Free Electron Laser at SLAC reported first lasing in April of 2009. Since then two successful user runs have been completed at the two soft x-ray stations. The first hard x-ray station has started commissioning in July of 2010. Beam diagnostics play an essential role for tuning the machine and delivering the requested beam properties to the users. An overview of the LCLS photon diagnostics will be presented including some selected commissioning results. Plans for future improvements and upgrades will be briefly discussed.

43 PARTICLE ACCELERATORS↗

Operation and Upgrades of the LCLS*

The LCLS FEL began user operations in September 2009 with photon energies from 800eV to 2 KeV and pulse energies above 2 mJ. Both long pulse (50-200 femtosecond FWHM) and short pulse (<10 femtosecond FWHM at 150 uJ) pulses were delivered at user request. In addition the FEL was operated at fundamental photon energies up to 10 KeV in preparation for hard X-ray experiments. FEL operating parameters, performance and reliability results will be presented, in addition to plans for upgrades to the facility.

Accelerators,ACCPHY, XFEL↗

Operational Performance of LCLS Beam Instrumentation

The Linac Coherent Light Source (LCLS) X-ray FEL utilizing the last km of the SLAC linac has been operational since April 2009 and finished its first successful user run last December. The various diagnostics for electron beam properties including beam position monitors, wire scanners, beam profile monitors, and bunch length diagnostics are presented as well as diagnostics for the X-ray beam. The low emittance and ultra-short electron beam required for X-ray FEL operation has implications on the transverse and longitudinal diagnostics. The coherence effects of the beam profile monitors and the challenges of measuring fs long bunches are discussed.

43 PARTICLE ACCELERATORS↗