Search NASA⌕ Search

Engineering topics

Eftekhari, Abe

Publications and source records attributed to Eftekhari, Abe.

23 records · Page 2

Free volume in contact lens polymers

We have measured the free volume and gas permeability in several contact lens specimens as part of a Space Commercialization Program. Free volume was measured using positron lifetime spectroscopy, while permeability for O2, N2, and CO2 gases was measured using mass spectrometry and polarography. It has been noted that permeability for all gases increases with the mean free volume cell size in the test samples. As might be expected, the specimens with the highest free volume fraction also exhibit the lowest Rockwell Hardness Number. An interesting corollary of this study is the finding that the presence of fluorine atoms in the lens chemical structure inhibits filling up of their free volume cells. This is expected to allow the lenses to breathe freely while in actual use.

Singh, Jag J.↗

A study of physical properties of ODPA-p-PDA polyimide films

Physical properties were investigated of ODPA-p-PDA polyimide films, including their lower molecular weight versions with phthalimide endcaps. Free volume, determined by low energy positron annihilation in the test films, was the major parameter of interest since all other physical properties are ostensibly related to it. It affects the dielectric constant as well as the saturation moisture pickup of the test films. An empirical relation was developed between the free volume and molecular weight of the test films, comparable to the Mark-Houwink relation between the polymer solution viscosity and the molecular weight. Development of such a relation constitutes a unique achievement since it enables researchers to estimate the molecular weight of an intractable polymer in solid state for the first time.

Singh, Jag J.↗

Low energy gamma ray attenuation in multiphase water

A gauging system is proposed to enable monitoring of slush density, solid-liquid interface, and slush level as well as its flow rate. It is based on the principle that the electromagnetic radiation mass attenuation coefficient of a multiphase chemical compound is constant for all relative phase concentrations. Results showing the essential constancy of mass attenuation coefficients for single-phase water vapor, liquid water, ice, and multiphase mixtures of water/ice are described.

Singh, Jag J.↗

A capacitive technique for real-time monitoring polymer coating thickness on carbon filaments during prepregging process

A technique for gauging the coating thickness during prepreg processing of carbon fibers was developed. It is based on the concept of measuring the capacitance of a cylindrical condenser through which a bundle of prepregged fibers is passed axially. Empirical results indicate the capacitance of this condenser element is linearly related to the polymer coating thickness on the fibers in the bundle. The capacitive transducer was successfully used to measure the polymer thickness on several test fiber bundles under static conditions.

Eftekhari, Abe↗

A slow positron beam generator for lifetime studies

A slow positron beam generator using well-annealed polycrystalline tungsten moderators and a Na-22 positron source was developed. A 250 micro c source, deposited on a 2.54 micron thick aluminized mylar, is sandwiched between two (2.54 cm x 2.54 cm x 0.0127 cm) tungsten pieces. Two (2.54 cm x 2.54 cm x t cm) test polymer films insulate the two tungsten moderator pieces from the aluminized mylar source holder (t=0.00127 to 0.0127). A potential difference of 10 to 100 volts--depending on the test polymer film thickness (t)--is applied between the tungsten pieces and the source foil. Thermalized positrons diffusing out of the moderator pieces are attracted to the source foil held at an appropriate potential below the moderator pieces. These positrons have to pass through the test polymer films before they can reach the source foil. The potential difference between the moderator pieces and the aluminized mylar is so adjusted as to force the positrons to stop in the test polymer films. Thus the new generator becomes an effective source of positrons for assaying thin polymer films for their molecular morphology.

Singh, Jag J.↗