Search NASA⌕ Search

Engineering topics

Eggert, J. H.

Publications and source records attributed to Eggert, J. H..

At least 19 records

Measurements of K-edge and L-edge extended x-ray absorption fine structure at the national ignition facility (invited)

High-energy-density laser facilities and advances in dynamic compression techniques have expanded access to material states in the Terapascal regime relevant to inertial confinement fusion, planetary science, and geophysics. However, experimentally determining the material temperature in these extreme conditions has remained a difficult challenge. Extended X-ray Absorption Fine Structure (EXAFS), referring to the modulations in x-ray absorption above an absorption edge from photoelectrons’ interactions with neighboring atoms, has proven to be a versatile and robust technique for probing material temperature and density for mid-to-high Z elements under dynamic compression. The current platform at the National Ignition Facility has developed six configurations for EXAFS measurements between 7 and 18 keV for different absorption edges (Fe K, Co K, Cu K, Ta L3, Pb L3, and Zr K) using a curved-crystal spectrometer and a bright, continuum foil x-ray source. Here, in this work, we describe the platform geometry, x-ray source performance, spectrometer resolution and throughput, design considerations, and data in ambient and dynamic-compression conditions.

36 MATERIALS SCIENCE↗

Developing time-resolved x-ray diffraction diagnostics at the National Ignition Facility (invited)

As part of a program to measure phase transition timescales in materials under dynamic compression, we have designed new x-ray imaging diagnostics to record multiple x-ray diffraction measurements during a single laser-driven experiment. Our design places several ns-gated hybrid CMOS (hCMOS) sensors within a few cm of a laser-driven target. The sensors must be protected from an extremely harsh environment, including debris, electromagnetic pulses, and unconverted laser light. Another key challenge is reducing the x-ray background relative to the faint diffraction signal. Building on the success of our predecessor (Target Diffraction In Situ), we implemented a staged approach to platform development. First, we built a demonstration diagnostic (Gated Diffraction Development Diagnostic) with two hCMOS sensors to confirm we could adequately protect them from the harsh environment and also acquire acceptable diffraction data. This allowed the team to quickly assess the risks and address the most significant challenges. Here, we also collected scientifically useful data during development. Leveraging what we learned, we recently developed a much more ambitious instrument (Flexible Imaging Diffraction Diagnostic for Laser Experiments) that can field up to eight hCMOS sensors in a flexible geometry and participate in back-to-back shots at the National Ignition Facility (NIF). The design also allows for future iterations, such as faster hCMOS sensors and an embedded x-ray streak camera. The enhanced capabilities of the new instrument required a much more complex design, and the unexpected issues encountered on the first few shots at NIF remind us that complexity has consequences. Our progress in addressing these challenges is described herein, as is our current focus on improving data quality by reducing x-ray background and quantifying the uncertainties of our diffraction measurements.

36 MATERIALS SCIENCE↗

Design of a Three-Layer Impactor for Material Strength Measurements at Multi-Megabar Pressures

Off-Hugoniot loading methods for dynamic compression have been a topic of interest for many years as a means of accessing high pressures without melting a material. Simulations and an initial test experiment of a three-layer gas-gun impactor suitable for use in measuring dynamic material strength at multi-megabar pressures are described. As shown through ARES hydrocode simulations, an impactor consisting of a low-, medium-, and high-impedance material, such as TPX, Al, and Ta or Pt, can produce a quasi-isentropic loading path up to 4.6 Mbar pressure with a low homologous temperature (T/T melt = 0.1–0.25). These impactors can also be tailored to create a pressure drive suitable for a Lagrangian sound speed experiment. Simulated in-situ velocities were analyzed to determine the change in calculated strength due to non-uniformity in the impactor, which provides a measure of error sensitivity. An initial test of a three-layer projectile onto a flat target at 4.4 km/s impact velocity is reported. Finally, while the impactor incurred some delamination during firing, the measured sample/window interface velocity generally agrees with the simulated peak velocity and subsequent release, indicating the feasibility of this approach for measuring material strength.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Time resolved X-ray diffraction using the FIDDLE diagnostic at NIF: Preliminary assessment of diffraction precision

The Flexible Imaging Diffraction Diagnostic for Laser Experiments (FIDDLE) is a new diagnostic at the National Ignition Facility (NIF) designed to observe in situ solid-solid phase changes at high pressures using time resolved X-ray diffraction. FIDDLE currently incorporates five Icarus Ultrafast X-ray Imager sensors that take 2 ns snapshots and can be tuned to collect X-rays for tens of ns. The platform utilizes the laser power at NIF for both the laser drive and the generation of 10 keV X-rays for ~10 ns using a Ge backlighter foil. We aim to use FIDDLE to observe diffraction at different times during compression to probe the kinetics of phase changes. Pb undergoes two solid-solid phase transitions during ramp compression: from FCC to HCP and HCP to BCC. Results will be reported on some of the first shots using the FIDDLE diagnostic at NIF on ramp compressed Pb to a peak pressure of ~110 GPa and a single undriven CeO2 calibration shot. A discussion of the uncertainties in the observed diffraction is included.

Vennari, C. E.↗

Shock compression experiments using the DiPOLE 100-X laser on the high energy density instrument at the European x-ray free electron laser: Quantitative structural analysis of liquid Sn

X-ray free electron laser (XFEL) sources coupled to high-power laser systems offer an avenue to study the structural dynamics of materials at extreme pressures and temperatures. The recent commissioning of the DiPOLE 100-X laser on the high energy density (HED) instrument at the European XFEL represents the state-of-the-art in combining x-ray diffraction with laser compression, allowing for compressed materials to be probed in unprecedented detail. Here, we report quantitative structural measurements of molten Sn compressed to 85(5) GPa and ~3500 K. The capabilities of the HED instrument enable liquid density measurements with an uncertainty of ~1% at conditions which are extremely challenging to reach via static compression methods. We discuss best practices for conducting liquid diffraction dynamic compression experiments and the necessary intensity corrections which allow for accurate quantitative analysis. We also provide a polyimide ablation pressure vs input laser energy for the DiPOLE 100-X drive laser which will serve future users of the HED instrument.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Nonplanar effects in simulations of laser-driven ejecta microjet experiments

Recent experiments of laser-driven ejecta microjets performed at OMEGA 60 reveal tortuous jets whereby the jets appear to deviate from their initial trajectory as they travel in vacuum. To understand these data, we perform two dimensional numerical simulations, considering different target thicknesses, pressures, and models of the drive conditions. In particular, modeling the finite laser spot size appears essential in reproducing qualitatively the non-planar shock observed in the experiment. Simulations capture jet deflection by accounting for a slight misalignment of the laser pointing with respect to the groove axis along with spatial variation of the laser pulse intensity. The principal physical mechanism appears to be that lateral momentum is imparted by release waves arising from the non-planar drive. The induced off-axis velocity is small in comparison to the jet axial velocity but integrates into a pronounced deflection over the course of the experiment. The analysis of jet axial and lateral mass distributions is found to be reproduced reasonably by the simulations. Simulated radiographs are in qualitative agreement with the experiments, though their differences point to potential shortcomings in modeling strictly three-dimensional experiments using two-dimensional hydrodynamic simulations. The simple analysis is able to explain part of the observed discrepancy in simulated vs experimental jet masses.

42 ENGINEERING↗

Evidence for dissociation in shock-compressed methane

Theory and experiments show that with increasing pressure, the chemical bonds of methane rearrange, leading to the formation of complex polymers and then to dissociation. However, there is disagreement on the exact conditions where these changes take place. In this study, methane samples were precompressed in diamond-anvil cells and then shock compressed to pressures reaching 400 GPa, the highest pressures yet explored in methane. Furthermore, the results reveal a qualitative change in the Hugoniot curve at 80-150 GPa, which is interpreted as a signature of dissociation based on thermodynamic calculations and theoretical predictions.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Time-resolved X-ray diffraction diagnostic development for the National Ignition Facility

Here we present the development of an experimental platform that can collect four frames of x-ray diffraction data along a single line of sight during laser-driven, dynamic-compression experiments at the National Ignition Facility. The platform is comprised of a diagnostic imager built around ultrafast sensors with a 2-ns integration time, a custom target assembly that serves also to shield the imager, and a 10-ns duration, quasi-monochromatic x-ray source produced by laser-generated plasma. We demonstrate the performance with diffraction data for Pb ramp compressed to 150 GPa and illuminated by a Ge x-ray source that produces ∼7 × 10 11 , 10.25-keV photons/ns at the 400 μm diameter sample.

36 MATERIALS SCIENCE↗

Dynamic optical spectroscopy and pyrometry of static targets under optical and x-ray laser heating at the European XFEL

Experiments accessing extreme conditions at x-ray free electron lasers (XFELs) involve rapidly evolving conditions of temperature. Here, we report time-resolved, direct measurements of temperature using spectral streaked optical pyrometry of x-ray and optical laser-heated states at the High Energy Density instrument of the European XFEL. This collection of typical experiments, coupled with numerical models, outlines the reliability, precision, and meaning of time dependent temperature measurements using optical emission at XFEL sources. Dynamic temperatures above 1500 K are measured continuously from spectrally- and temporally-resolved thermal emission at 450–850 nm, with time resolution down to 10–100 ns for 1–200 μs streak camera windows, using single shot and integrated modes. Targets include zero-pressure foils free-standing in air and in vacuo, and high-pressure samples compressed in diamond anvil cell multi-layer targets. Radiation sources used are 20-fs hard x-ray laser pulses at 17.8 keV, in single pulses or 2.26 MHz pulse trains of up to 30 pulses, and 250-ns infrared laser single pulses. A range of further possibilities for optical measurements of visible light in x-ray laser experiments using streak optical spectroscopy are also explored, including for the study of x-ray induced optical fluorescence, which often appears as background in thermal radiation measurements. We establish several scenarios where combined emissions from multiple sources are observed and discuss their interpretation. Challenges posed by using x-ray lasers as non-invasive probes of the sample state are addressed.

47 OTHER INSTRUMENTATION↗

X-Ray Diffraction of Ramp-Compressed Silicon to 390 GPa

Silicon (Si) exhibits a rich collection of phase transitions under ambient-temperature isothermal and shock compression. This report describes in-situ diffraction measurements of ramp compressed Si between 40 and 389 GPa. Angle-dispersive x-ray scattering reveals that Si assumes an hexagonal close-packed (hcp) structure between 40 and 93 GPa, and, at higher pressure, a face-centered cubic (fcc) structure which persists to at least 389 GPa, the highest pressure for which the crystal structure of Si has been investigated. Furthermore, the range of hcp stability extends to higher pressures and temperatures than predicted by theory.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Ramp compression of tantalum to multiterapascal pressures: Constraints of the thermal equation of state to 2.3 TPa and 5000 K

We report measurements of the compressibility of ramp compressed tantalum to a final stress of 2.3 TPa corresponding to threefold volumetric compression. Using these data, we extended the experimental constraint on the Ta cold compression curve by an order of magnitude in pressure. Furthermore, by combining the resulting data with previous measurements of shock compression and ambient pressure heating, we construct an experimentally bounded and thermodynamically consistent equation of state model for Ta which has 2% uncertainty in pressure at 1 TPa. We therefore propose Ta as an in situ pressure scale for laser-heated static compression experiments which were recently able to reach terapascal pressures and thousands of degrees Kelvin. Our new equation of state of Ta is experimentally constrained at extreme pressures and temperatures relevant to a wide range of planetary interiors and will allow for more accurate comparison between experimental measurements and theory at extreme conditions.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Optimized x-ray emission from 10 ns long germanium x-ray sources at the National Ignition Facility

This study investigates methods to optimize quasi-monochromatic, ~10 ns long x-ray sources (XRS) for time-resolved x-ray diffraction measurements of phase transitions during dynamic laser compression measurements at the National Ignition Facility (NIF). To support this, we produce continuous and pulsed XRS by irradiating a Ge foil with NIF lasers to achieve an intensity of 2 × 10 15 W/cm 2 , optimizing the laser-to-x-ray conversion efficiency. Our x-ray source is dominated by Ge He-α line emission. Here, we discuss methods to optimize the source to maintain a uniform XRS for ~10 ns, mitigating cold plasma and higher energy x-ray emission lines.

47 OTHER INSTRUMENTATION↗

X-ray diffraction measurements and pressure determination in nanosecond compression of solids up to 600 GPa

X-ray diffraction measurements under laser-driven dynamic compression now allow us to investigate the atomic structure of matter at TPa pressures and thousands of degree temperatures with broad implications for condensed matter physics, planetary science and astronomy. Furthermore, pressure determination in these experiments often relies on velocimetry measurements coupled with modeling that requires accurate knowledge of the optical and thermo-mechanical properties of a window material, resulting in significant systematic uncertainty. Here we demonstrate different approach applicable to X-ray diffraction experiments under quasi-isentropic ramp-compression based on the use of in-situ pressure calibrants, similar to the methods often adopted in static-compression experiments with diamond anvil cells. Focusing on experiments using a diamond window, we discuss challenges and mitigation strategies for the novel approach. Our study, in addition to providing new structural information of 5 metals up to hundreds of GPa, provides validation to the currently used methods based on time-resolved measurement of the diamond free-surface velocity, and reveals that the use of in-situ calibrants enables a factor of four reduction in the pressure uncertainty in these experiments.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Structure and density of silicon carbide to 1.5 TPa and implications for extrasolar planets

There has been considerable recent interest in the high-pressure behavior of silicon carbide, a potential major constituent of carbon-rich exoplanets. In this work, the atomic-level structure of SiC was determined through in situ X-ray diffraction under laser-driven ramp compression up to 1.5 TPa; stresses more than seven times greater than previous static and shock data. Here we show that the B1-type structure persists over this stress range and we have constrained its equation of state (EOS). Using this data we have determined the first experimentally based mass-radius curves for a hypothetical pure SiC planet. Interior structure models are constructed for planets consisting of a SiC-rich mantle and iron-rich core. Carbide planets are found to be ~10% less dense than corresponding terrestrial planets.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Diamond formation in double-shocked epoxy to 150 GPa

We present measurements of diamond formation in doubly shocked Stycast 1266 epoxy (comprising C, H, Cl, N, and O) using in situ x-ray diffraction. Epoxy samples were reshocked against a LiF window to pressures between 80 and 148 GPa in experiments at the Omega Laser Facility. Furthermore, the pressure and temperature conditions were diagnosed in situ using velocimetry and optical pyrometry, respectively. X-ray diffraction patterns of the compressed epoxy are consistent with cubic diamond (Fd3¯m), indicating that diamond can precipitate not only from twice-shocked CH polystyrene [Kraus et al. Nat. Astron. 1, 606 (2017)] at these conditions but also from twice-shocked CH polymers with the addition of oxygen, nitrogen, and chlorine. These results, in combination with previous works on CH, CH 2 , CH 4 , and methane hydrate, support that diamond often, but not always, forms from CH-based compounds at extreme pressures and temperatures, indicating that the chemical composition, thermodynamic compression path, and kinetics play an important role.

36 MATERIALS SCIENCE↗

Metastability of Liquid Water Freezing into Ice VII under Dynamic Compression

The ubiquitous nature and unusual properties of water have motivated many studies on its metastability under temperature- or pressure-induced phase transformations. Here, nanosecond compression by a high-power laser is used to create the nonequilibrium conditions where liquid water persists well into the stable region of ice VII. Through our experiments, as well as a complementary theoretical/computational analysis based on classical nucleation theory, we report that the metastability limit of liquid water under nearly isentropic compression from ambient conditions is at least 8 GPa, higher than the 7 GPa previously reported for lower loading rates.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Establishing gold and platinum standards to 1 terapascal using shockless compression

New techniques are advancing the frontier of high-pressure physics beyond 1 terapascal, leading to new discoveries and offering stringent tests for condensed-matter theory and advanced numerical methods. However, the ability to absolutely determine the pressure state remains challenging, and well-calibrated pressure-density reference materials are required. We conducted shockless dynamic compression experiments at the National Ignition Facility and the Z machine to obtain quasi-absolute, high-precision, pressure-density equation-of-state data for gold and platinum. We derived two experimentally constrained pressure standards to terapascal conditions. Establishing accurate experimental determinations of extreme pressure will facilitate better connections between experiments and theory, paving the way toward improving our understanding of material response to these extreme conditions.

36 MATERIALS SCIENCE↗