Role of critical stress in quantifying the magnitude of fluid-injection triggered earthquakes
Not provided.
Engineering topics
Publications and source records attributed to Eijsink, Agathe.
Not provided.
This is a presentation on Seismicity-Permeability Relationships Probed via Nonlinear Acoustic Imaging by Pennsylvania State University, presented by Derek Elsworth. This video slide presentation discussed controls and acoustic signatures of aseismic through seismic evolution of relocation-stability-permeability on fractures in shear-reactivation as a precursor to, and a key predictor of, seismic moment magnitude of prospective triggered-seismicity. This presentation was featured in the Utah FORGE R&D Annual Workshop on August 13, 2024.
This repository contains experimental data from a series of fluid injection-induced shearing tests conducted on Utah FORGE granitoid. The experiments were performed using an aluminum triaxial pressure vessel (TEMCO) apparatus at Pennsylvania State University. The primary aim was to investigate the impact of temperature on fault seismicity and to explore how different pre-stress ratios influence shearing behavior. The data includes results from experiments conducted under varying conditions of temperature, pre-stress ratios, and pore pressure increments. The rock samples used in these experiments were 60-grit granitoid with a single inclined fracture oriented at 60 degrees with respect to the horizontal cross-section. The dataset also includes measurements of normal stiffness at different temperatures and images of the experimental apparatus. The included README file details each experiential setup and outlines which data files represent which experimental conditions.
This dataset contains experimental data from fluid injection experiments conducted to investigate the influence of temperature on fracture seismicity. The experiments were performed on granite samples from Utah FORGE. The samples were prepared with a 30-degree inclined fracture and subjected to controlled stress and temperature conditions. Data were collected under three distinct temperature settings: 24 C, 78 C, and 137 C. During the experiments, a constant confining pressure of 10 MPa and a constant shear stress at 80% of the shear strength of the sample were maintained. Pore pressure was incrementally increased at a rate of 300 kPa every three minutes to simulate fluid injection. Temperature was raised rapidly and then stabilized for the duration of each test. The dataset includes shear stress and displacement measurements under each temperature condition, along with supplementary figures illustrating the experimental setup and time-series plots of pressures and temperature.
Included are experimental data recorded from shear experiments that specifically explore the link between fluid-injection rate and seismic moment resulting from shear reactivation of laboratory faults. Raw mechanical data from three experiments are included alongside corresponding MATLAB scripts that import and plot the data, as well as use it to calculate shear and normal stress. Experiments are performed on 2.5-3 inch long granitoid cores from the Utah FORGE EGS demonstration site, containing a single inclined fracture with small-scale roughness added to the fracture surface. The raw data included here were recorded from an aluminum triaxial pressure vessel (TEMCO) configured with three independent servo-controlled pumps, with distilled water used as the working fluid. The pumps control confining pressure, upstream pore pressure, and axial pressure, with each pump connected to a LabView interface to record applied pressures, cumulative injected water volumes, and pump flow rates. The downstream outlet from the fracture is closed to allow pressurization, which is measured by an external pressure transducer. A linear variable differential transformer (LVDT) attached to the axial piston measures axial displacement, from which we calculate shear displacement along the fracture. Additionally, P-wave transducers are used to record acoustic signatures, where acoustic emission events and maximum amplitudes are compared against seismic moment and shear slip velocity. Fluid injection rates range between 0.05 mL/min, 0.25 mL/min, and 0.75 mL/min for each experiment. Along-fault pressure distributions are progressively less uniform as injection rates increase, representing a switch from steady-state to transient conditions. Triggered shear displacement is used as a proxy for seismic moment and is indexed against cumulative injection volume and rate. Each experiment is performed under constant shear stress conditions, and the sample is fully saturated with DI water. Axial and confining stresses are applied to 3 MPa through pressure-stepping in 500 kPa increments. The pore pressure is held constant at 200 kPa prior to initiating the experiment, and initial axial displacement is recorded. The axial stress is then increased to initiate shear mobilization during the loading phase (run-in) until a peak steady state is achieved. The initial shear stress is reduced to approximately 80% of the peak shear stress by decreasing the axial stress, then held constant for the duration of each experiment.
Included are data from triaxial, single-inclined-fracture friction experiments. The experiments were performed with slide-hold-slide protocol on Utah FORGE gneiss at increased temperature. With a ~10 MPa normal stress, temperatures vary between experiments from room temperature up to 163 Celsius. Hold times vary during experiment from ~10^1 to ~10^5 seconds. Measured are the frictional response upon reactivation after a hold period, active acoustic data (P-wave velocity and amplitude) and passive acoustic data (acoustic emission occurrence and amplitude). There are two types of datafiles: (1) Datafiles containing the friction data, including the temperature and the active acoustic data measured during the experiment (AEXX_Gneiss_Vp_mixref4). The underscore _Vp means that it includes the Vp or P-wave velocity data, with _mixref meaning that we use a mixed reference point for calculating the P-wave velocity. And (2) the datafiles containing the passive acoustics data, a catalog of the acoustic emissions (AE's) measured during the experiment (AEcatalog_AEXX_runX), where AEXX matches the experiment number and runX denotes which part of the experiment the data was collected, matching the times where active acoustic data was collected. AE catalogs are split in two parts when the file size exceeds 1 GB to aid download/opening times.
Included are results from shear reactivation experiments on laboratory faults pre-loaded close to failure and reactivated by the injection of fluid into the fault. The sample comprises a single-inclined-fracture (SIF) transecting a cylindrical sample of Westerly granite. All experiments are conducted at ambient temperature and follow a similar protocol: (i) application of confining stresses (3MPa) on the fault fully saturated with DI water, (ii) shear-mobilization through the increase of axial loading at a constant displacement rate until a post-peak steady-state condition is reached, (iii) reduction of axial loading and related shear stress to a prescribed fraction of the peak steady-state frictional strength (typically 60% to 90%, representing intermediate to high magnitudes) and (iv), fault reactivation triggered by a stepwise increase of pore pressure on the fault in 0.1 MPa increments held constant for 1-5 minutes. Mechanical data from three ISCO pumps connected to a Temco pressure vessel measure axial, confining, and fault-related parameters, including fluid pressure (kPa), fluid flow rate (mL/min), and axial displacement (mm). See included code for initial data analysis and visualization for select experiments. Resource names represent experiment numbers found in the "Read Me" file, which describes each experimental setup and parameters.
Laboratory experimental data on saw-cut interface of Westerly Granite and Utah Forge granitoid rocks. Experiments include velocity-stepping and fluid pressure stepping experiments. Mechanical data from 3 ISCO pumps connected to a Temco pressure vessel measure axial, confining and fault: fluid pressure (kPa), fluid flow rate (mL/min) and volume remaining in pump (mL). Non-linear acoustic data acquired via Verasonics systems connected to PZTs inside the pressure vessel give the timeshift, amplitude and RMS amplitude of the passing P-wave.