Search NASA⌕ Search

Engineering topics

Eilers, Hergen

Publications and source records attributed to Eilers, Hergen.

Progress towards subsurface spectroscopy inside heterogeneous materials using four wave mixing phase conjugation

Herein, we report preliminary results on subsurface spectroscopy inside heterogeneous materials using four wave mixing phase conjugation. For our test material we use an inert plastic bonded explosive simulant that contains fluorescent guidestar particles. Using phase conjugation, we are able to obtain spectral enhancements approximately equal to the phase conjugate reflectivity. Additionally, we discuss future directions to improve this technique to obtain greater signal enhancements.

47 OTHER INSTRUMENTATION↗

Subsurface Spectroscopy of Thermal Degradation Inside an Inert Plastic Bonded Explosive (PBX) Simulant Using Feedback-Assisted Wavefront Shaping

We characterize the subsurface thermal degradation of an inert analog of high-explosive molecular crystals (Eu:Y(acac) 3 (DPEPO)) (EYAD) embedded inside of a plastic bonded explosive simulant using feedback-assisted wavefront shaping-based fluorescence and Raman spectroscopies. This technique utilizes wavefront shaping to focus pump light inside a heterogeneous material onto a target particle, which significantly improves its spectroscopic signature. We find that embedding the EYAD crystals in the heterogeneous polymer results in improved thermal stability, relative to bare crystal measurements, with the crystal remaining fluorescent to >612 K inside of the heterogeneous material, while the bare crystal’s fluorescence is fully quenched by 500 K. We hypothesize that this improvement is due to the polymer restricting the effects of EYAD melting, which occurs at 400 K and is the primary mechanism for spectroscopic changes in the temperature range explored.

Anderson, Benjamin R.↗

Fluorescence-Based Aqueous Phosphate Sensing Using Eu(cpboda)(DMF) 2

Fluorescence-based phosphate sensing using phosphate-sensitive phosphors is a promising approach for in situ monitoring of phosphate pollution in waterways and reservoirs. To date, the most sensitive phosphor developed for this purpose is Tb(cpboda)(DMF) 2 , where cpboda = (3,3'-((5-Carboxy-1,3-phenylene)bis(oxy))dibenzoic acid). In this study, we further improve this sensitivity by replacing the Tb 3+ ions with Eu 3+ ions to make Eu(cpboda)(DMF) 2 and find concentration-independent phosphate-sensitivity of 1570 ± 120, which is ≈8× more sensitive than the Tb-version. This improvement is attributed to Eu 3+ having a hypersensitive transition, while Tb 3+ does not. Additionally, we characterize the phosphor’s optical properties, photodegradation, and water solubility. We find that the phosphor presents challenges with regards to both photodegradation and solubility, as it is found to be poorly soluble in water and is quickly photodegraded under UV radiation <360 nm. However, these obstacles can, in theory, be overcome with the use of direct excitation of the Eu 3+ ions at 394 nm and careful design of an analysis instrument to reduce concentration variations.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Aqueous phosphate detection using Eu(acac) 3

Currently, the majority of phosphate-sensitive phosphors reported in literature are metal-based complexes that require complicated and expensive synthesis to prepare. Here, in this study, we investigate the phosphate detecting capabilities of an inexpensive off-the-shelf phosphor: Eu(acac) 3 . We characterize its phosphate sensitivity as a function of sensor concentration and find that the quenching coefficient is inversely proportional to sensor concentration. This results in the limit-of-detection scaling linearly with sensor concentration. We determine its concentration-independent sensitivity to be 1.558 ± 0.012, which results in our lowest sensor concentration (44 μM) having a limit-of-detection of 3.39 ± 0.68 μM. We also find that for phosphate concentrations less than the sensor concentration, the fluorescence intensity ratio behaves linearly, but transitions to a non-linear functionality as the phosphate concentration exceeds the sensor concentration.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Subsurface spectroscopy of heterogeneous materials using optical wavefront shaping

Plastic-bonded explosives and propellants consist of energetic molecular crystals embedded in a polymer matrix that also includes additives, such as taggants, plasticizers, grit, antioxidants, etc. Furthermore, this heterogeneous composition renders these materials optically opaque, limiting optical characterization techniques (e.g., Raman spectroscopy) to probing chemical reactions at the sur-face. However, many reactions of interest are believed to occur inside the material where current optical techniques can not probe. To address this challenge, we have developed a new optical technique that utilizes feedback assisted wavefront shaping (using spatial light modulators) to focus probe light inside a heterogeneous material, such that we can perform subsurface spectroscopy. Recently, we demonstrated this technique by monitoring subsurface photodegradation and thermal degradation of Eu-doped molecular crystals using both fluorescence and Raman spectroscopy. Based off these successes we are now looking into improvements to this technique to allow for greater time resolution, including replacing our spatial light modulators with fast digital mirror devices, using ns optical phase conjugation, and self-healing optical beams.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Development of a Portable In Situ Phosphorous Sensor

While phosphorus is a critical nutrient for all forms of life, runoff leads to phosphorus accumulation in surface water where it can cause a variety of health, environmental, and economic problems. The Department of Energy is interested in conducting long-term field experiments to monitor the impact of phosphorus in terrestrial and aquatic environments, and to better understand a cost vs. benefit analysis of reducing phosphorus pollution. Performing such long-term experiments requires affordable sensors capable of monitoring low-level phosphorus concentrations under challenging environmental conditions. However, such sensors are currently not available. The goal of this proposed project is to develop and demonstrate a low-cost portable phosphorus sensor suitable for in situ measurements. We will determine the technical requirements for a Raman-based sensor system, design and build a signal amplifier, integrate it with a Raman-based sensor, and demonstrate a proof-of-concept level sensor system. The expected accomplishments for Phase I include the identification of the technical requirements of a combined Raman laser/spectrometer and cavity enhancement system, building a proof-of-concept level sensor system capable of detecting orthophosphate compounds at the desired level of 0.25 mg P/L and organic P compounds, and verification of the sensor performance under laboratory and field conditions. In addition, we will identify initial hardening requirements that will need to be implemented during Phase II. While we plan to develop an integrated sensor system for monitoring phosphorus, the cavity-based enhancement system can also be used in combination with other (non-phosphorus) Raman sensors that we plan to develop or that are already commercially available. A recent market report highlights the increasing demand for such environmental monitoring applications, with the market for chemical detection anticipated to grow at a compound annual growth rate of 6.5% (2020-2025). Wide-spread monitoring of phosphorus could reduce the damage from eutrophication in freshwater, which is estimated to be $2.2 billion annually, thereby increasing biodiversity, reducing costs required for drinking water treatment, and decreasing economic losses related to recreation and angling and lake property values.

54 ENVIRONMENTAL SCIENCES↗

Development of an Environmentally Acceptable Hydraulic Fluid

Hydroelectric plants operators like the United States Army Corps of Engineers seek their traditional petroleum-based fluids with environmentally acceptable hydraulic fluids (EAHF) to reduce their impact and liability related to spills and leakages to the water and environment. Artesion, Inc. and its sub-contractor Washington State University (WSU) sought to optimize WSU’s existing EAHF blend into an improved product that would demonstrate long-term stability while meeting the EAHF requirements of the EPA’s Vessel General Permit (VGP). Multiple rounds of Design of Experiments testing were performed from WSU’s base formulation, modifying mixing ratios to generate multiple test fluids. These fluids were then tested for hydraulic fluid properties. It was found that there was a significant tradeoff between oxidative stability and biodegradability; highly stable materials were not sufficiently biodegradable, while the highly biodegradable materials quickly failed in stability tests. After four rounds of Design of Experiments, AI and WSU had found a base fluid which met the VGP, but only had a Rotating Pressure Vessel Oxidative Test (RPVOT) of 284-minute RPVOT stability, far short of the 500-minute target that would be needed for hydroelectric plants. It was determined that WSU’s route had shown initial promise but needed more refinement to be able to produce an acceptable EAHF.

36 MATERIALS SCIENCE↗

Raman Spectroscopy for the On-Line Analysis of Oxidation States of Oxygen Carrier Particles (Final Report)

The need for cleaner energy systems, including CO 2 capture technologies, is driving the current development of chemical looping technologies such as chemical looping combustion (CLC) and chemical looping gasification (CLG). Specific processes that are under development for using solid fuels are in-situ Gasification Chemical-Looping Combustion (iG-CLC) and Chemical Looping with Oxygen Uncoupling (CLOU). Chemical looping is based on using oxygen carriers (e.g., iron oxides, copper oxides, calcium sulfates, etc.) to provide the oxygen for the reaction with the fuel. In order to optimize the overall process performance, it is critical that the properties of the oxygen carriers are well-defined and maintained for their specific purpose during the different stages of the CLC process. One of the critical properties of the oxygen carrier is its oxidation state (e.g., content of Fe 2 O 3 vs. Fe 3 O 4 ) as it affects the fundamental operation of the CLC process. Unfortunately, the ability to make on-line measurements of the oxidation state of oxygen carriers is lacking and new sensors need to be developed. The goal of this project was to evaluate the potential of Raman spectroscopy as a sensor for the on-line analysis of the oxidation state of oxygen carrier particles. Oxygen carrier particles (OCPs) of interest include iron oxides, copper oxides, calcium sulfite, and calcium sulfate, with particle sizes typically less than 0.5 mm diameter. The expected operating conditions of the sensor include OCP temperatures in the range of 800 °C to 1000 °C, and pressures of about 10 atm. We evaluated continuous wave (cw), Quasi cw, pulsed, and time-gated Raman spectroscopy at multiple wavelengths (355 nm, 360 nm, 532 nm, 633 nm, 785 nm). Samples included iron oxides, copper oxides, calcium sulfate, and a custom sample provided by NETL for temperatures beyond 1000 °C. Our findings can be summarized as follows: Calcium sulfate can be detected via cw and pulsed 532 nm Raman spectroscopy at temperatures above 1100 °C.; Hematite (Fe 2 O 3 ) Raman spectra can be detected at temperatures of 700 °C via cw 360 nm, 1089 °C with cw 532 nm, 400 °C with cw 633 and 600 °C with cw 785 nm lasers; Magnetite (Fe 3 O 4 ) can be detected via cw 532 nm Raman spectroscopy up to 600 °C; Mixtures of Fe2O3 and Fe 3 O 4 can be distinguished for temperatures up to 600 °C using 532 nm; Copper oxides did not yield suitable signals at elevated temperatures; The custom NETL samples did not yield suitable signals at elevated temperatures. Raman spectroscopy would be a suitable approach for calcium sulfate as this material provides a very strong Raman signal at high temperatures. Oxygen carrier particles of higher interest such as metal oxides, however, do not yield a strong-enough signal at elevated temperatures. As such, Raman spectroscopy is not suitable to differentiate the oxidation state of these materials at temperatures above 600 °C.

01 COAL, LIGNITE, AND PEAT↗

Raman Spectroscopy for the On-Line Analysis of Oxidation States of Oxygen Carrier Particles

The need for cleaner energy systems, including CO 2 capture technologies, is driving the current development of chemical looping technologies such as chemical looping combustion (CLC) and chemical looping gasification (CLG). Specific processes that are under development for using solid fuels are in-situ Gasification Chemical-Looping Combustion (iG-CLC) and Chemical Looping with Oxygen Uncoupling (CLOU). Chemical looping is based on using oxygen carriers (e.g., iron oxides, copper oxides, calcium sulfates, etc.) to provide the oxygen for the reaction with the fuel. In order to optimize the overall process performance, it is critical that the properties of the oxygen carriers are well-defined and maintained for their specific purpose during the different stages of the CLC process. One of the critical properties of the oxygen carrier is its oxidation state (e.g., content of Fe 2 O 3 vs. Fe 3 O 4 ) as it affects the fundamental operation of the CLC process. Unfortunately, the ability to make on-line measurements of the oxidation state of oxygen carriers is lacking and new sensors need to be developed. The goal of this project was to evaluate the potential of Raman spectroscopy as a sensor for the on-line analysis of the oxidation state of oxygen carrier particles. Oxygen carrier particles (OCPs) of interest include iron oxides, copper oxides, calcium sulfite, and calcium sulfate, with particle sizes typically less than 0.5 mm diameter. The expected operating conditions of the sensor include OCP temperatures in the range of 800 °C to 1000 °C, and pressures of about 10 atm. We evaluated continuous wave (cw), Quasi cw, pulsed, and time-gated Raman spectroscopy at multiple wavelengths (355 nm, 360 nm, 532 nm, 633 nm, 785 nm). Samples included iron oxides, copper oxides, calcium sulfate, and a custom sample provided by NETL for temperatures beyond 1000 °C. Our findings can be summarized as follows: Calcium sulfate can be detected via cw and pulsed 532 nm Raman spectroscopy at temperatures above 1100 °C. Hematite (Fe 2 O 3 ) Raman spectra can be detected at temperatures of 700 °C via cw 360 nm, 1089 °C with cw 532 nm, 400 °C with cw 633 and 600 °C with cw 785 nm lasers. Magnetite (Fe 3 O 4 ) can be detected via cw 532 nm Raman spectroscopy up to 600 °C. Mixtures of Fe 2 O 3 and Fe 3 O 4 can be distinguished for temperatures up to 600 °C using 532 nm. Copper oxides did not yield suitable signals at elevated temperatures. The custom NETL samples did not yield suitable signals at elevated temperatures. Raman spectroscopy would be a suitable approach for calcium sulfate as this material provides a very strong Raman signal at high temperatures. Oxygen carrier particles of higher interest such as metal oxides, however, do not yield a strong-enough signal at elevated temperatures. As such, Raman spectroscopy is not suitable to differentiate the oxidation state of these materials at temperatures above 600 °C.

01 COAL, LIGNITE, AND PEAT↗

A comparison of pulsed and continuous lasers for high-temperature Raman measurements of anhydrite

Oxygen carrier particles (OCPs) serve as fuel oxidant in emerging chemical looping combustion systems. However, chemical looping combustion process optimization is hindered by the lack of online sensors for measurements of OCP oxidation states at temperatures up to 1,000 °C and pressures up to 10 atm. We are investigating Raman spectroscopy as a potential solution, as this technique is known for its ability to provide noninvasive, molecularly specific information in real time in a wide variety of applications. As a case study, Raman spectra from high–temperature (>1,000 °C) anhydrite, a potential OCP, are presented using pulsed and continuous wave excitation at 532 nm. When pulsed excitation is coupled with time–gated detection, background signal from thermal radiation can be significantly reduced from single pulse spectra, outperforming results using an ungated detector. Also, laser heating of the sample is not observed but laser–induced breakdown spectra increasingly appear with increasing temperature and pulse intensity. Compared with pulsed excitation, continuous wave excitation with longer acquisition time, offers higher signal to noise and avoids the risk for laser–induced breakdown spectra but demonstrates minor sample heating. Finally, the data demonstrate practical utility by (a) providing a calibration of anhydrite's ν 1 (1,017 cm –1 ) Raman temperature–dependent band position and by (b) providing estimates of temperature using the ratios of the Stokes/anti–Stokes ν 1 integrated intensities. Furthermore, these results demonstrate the first high–temperature, pulsed Raman spectra from anhydrite while evaluating challenges associated with high–temperature, Raman measurements of OCP materials in general.

20 FOSSIL-FUELED POWER PLANTS↗

Raman Spectroscopy for the On Line Analysis of Oxidation States of Oxygen Carrier Particles

The need for cleaner energy systems, including CO 2 capture technologies, is driving the current development of new combustion approaches such as chemical looping combustion (CLC). This process is based on using oxygen carrier particles (OCPs) such as iron oxides, copper oxides, calcium sulfates, etc. to provide the oxygen for the combustion process. In order to optimize the overall process performance, it is critical that the properties of the oxygen carriers are well-defined and maintained for their specific purpose during the different stages of the CLC process. One of the critical properties of the oxygen carrier is its oxidation state (e.g., content of Fe 2 O 3 vs. Fe 3 O 4 ) as it affects the fundamental operation of the CLC process. Unfortunately, the ability to make on-line measurements of the oxidation state of oxygen carriers is lacking and new sensors need to be developed. Our goal is to develop a sensor for the on-line analysis of the oxidation state of oxygen carrier particles and to demonstrate its feasibility. Oxygen carrier particles (OCPs) of interest include iron oxides, copper oxides, and calcium sulfate, with particle sizes typically less than 0.5 mm diameter. The expected operating conditions of the sensor include OCP temperatures in the range of 800 °C to 1000 °C, and pressures of about 10 atm. The expected results are to be of a statistical nature, providing relative concentrations of the different oxidation states. These requirements make a strong case for using non-contact, stand-off, pulsed Raman spectroscopy as a sensor for the high-temperature on-line analysis of oxygen carrier particles. In order to achieve our goal, we have set up and tested a pulsed Raman spectroscopy system in combination with a pressurized high-temperature sample chamber, and have taking initial Raman spectra of various materials at high temperature. We are now in the process of optimizing the operating parameters such as laser wavelength, laser intensity, collection optic design, focal spot size, data acquisition, etc. We will also develop an analysis procedure for the interpretation of the Raman spectra. Typical Raman spectra consist of a convolution of background signal and multiple individual spectra. In order to extract relevant information such as the concentration ratio of a material in different oxidation states, we need to process (background subtraction, deconvolution, fitting, etc.) the measured data. In addition, statistical modeling and multivariate calibration need to be performed to correctly analyze the Raman spectra.

20 FOSSIL-FUELED POWER PLANTS↗

Spectroscopic determination of thermal impulse in sub-second heating events using lanthanide-doped oxide precursors and phenomenological modeling

Using a mixture of crystalline-Ho:ZrO{sub 2}, precursor-Dy:Y{sub 2}O{sub 3}, and precursor-Eu:ZrO{sub 2} nanoparticles we develop thermal impulse sensors capable of measuring equivalent isothermal temperatures and durations during a heating event, with response times of <100 ms, and a temperature range of at least 673 K to 1173 K. In order to determine the temperature and duration from the sensors after the heating event we measure the sensors' fluorescence spectrum, which is then compared with lab based calibration data. By using two precursor materials with different reaction kinetics we are able to extract both temperature and duration. Based on blind sample testing we find that the sensors and calculation method are accurate for measuring temperature and duration, but currently suffer a lack of precision due to difficulties in producing homogeneously heated samples.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Irreversible phase transitions due to laser-based T-jump heating of precursor Eu:ZrO{sub 2}/Tb:Y{sub 2}O{sub 3} core/shell nanoparticles

Amorphous precursors of Eu-doped-ZrO{sub 2}/Tb-doped-Y{sub 2}O{sub 3} (p-Eu:ZrO{sub 2}/p-Tb:Y{sub 2}O{sub 3}) core/shell nanoparticles are rapidly heated to temperatures between 200 °C and 950 °C for periods between 2 s and 60 s using a CO{sub 2} laser. During this heating process the nanoparticles undergo irreversible phase changes. The fluorescence spectra due to Eu{sup 3+} dopants in the core and Tb{sup 3+} dopants in the shell are used to identify distinct phases within the material and to generate time/temperature phase diagrams. Such phase diagrams can potentially help to determine unknown time/temperature histories in thermosensor applications. - Graphical abstract: A CO{sub 2} laser is used for rapid heating of p-Eu:ZrO{sub 2}/p-Tb:Y{sub 2}O{sub 3} core/shell nanoparticles. Optical spectra are used to identify distinct phases and to determine its thermal history. - Highlights: • Synthesized oxide precursors of lanthanide doped core/shell nanoparticles. • Heated core/shell nanoparticles via laser-based T-jump technique. • Observed time- and temperature-dependent irreversible phase transition.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Correlation of optical properties and temperature-induced irreversible phase transitions in europium-doped yttrium carbonate nanoparticles

Nanophase europium-doped yttrium carbonate precursors are subjected to heat treatments, ranging from 300 Degree-Sign C to 1100 Degree-Sign C for dwell times of 5 min, 30 min, and 180 min. XRD, TEM, FT-IR, fluorescence, fluorescence excitation, and fluorescence lifetime measurements are used to characterize the materials. Upon heating, the material transitions through several amorphous stages until it reaches the crystalline cubic Y{sub 2}O{sub 3} phase. DSC measurements show an exothermic transition at 665.7 Degree-Sign C, indicating the formation of crystalline Y{sub 2}O{sub 3}. The grain size development is fitted by the relaxation equation and yields an activation energy of 50.3 kJ/mol. The amorphous phases are characterized by inhomogenously broadened optical spectra. Heating up to 700 Degree-Sign C leads to an increased fluorescence lifetime (from about 1 ms to 2.4 ms). As the material is heated to higher temperatures and completes the formation of the crystalline cubic Y{sub 2}O{sub 3} phase, the optical spectra become narrower and the fluorescence lifetime decreases to about 1.2 ms. - Graphical abstract: Fluorescence lifetimes of Eu-doped Y{sub 2}O{sub 3} precursors heated for 5, 30, and 180 min to various temperatures. Highlights: Black-Right-Pointing-Pointer Irreversible phase transitions in nanoparticles are of interest for thermometry. Black-Right-Pointing-Pointer Eu-doped nanophase yttrium carbonate precursors were heat-treated. Black-Right-Pointing-Pointer The material undergoes decomposition and crystallization. Black-Right-Pointing-Pointer Morphological and optical properties are measured. Black-Right-Pointing-Pointer Optical properties can be used to deduce the temperature.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Light-induced structural changes in Eu-doped (Pb,La)(Zr,Ti)O{sub 3} ceramics

Fluorescence spectra of poled and unpoled Eu-doped (Pb,La)(Zr,Ti)O{sub 3} ceramics with various compositions were measured using 580 nm excitation. The ratio of the intensities of the Eu{sup 3+} {sup 5}D{sub 0}{yields}{sup 7}F{sub 2}/{sup 5}D{sub 0}{yields}{sup 7}F{sub 1} fluorescence transitions was used as an indicator for the symmetry of the Eu{sup 3+} site. As the symmetry decreases, the ratio increases. Increasing the Zr content in (Pb,La)(Zr,Ti)O{sub 3} increases the ratio, indicating that the symmetry of the Eu{sup 3+} site decreases. Exposure of the Eu-doped (Pb,La)(Zr,Ti)O{sub 3} samples to UV light also increases the intensity ratio, indicating that UV light exposure leads to structural distortions in Eu-doped (Pb,La)(Zr,Ti)O{sub 3} samples, lowering the Eu{sup 3+} site symmetry.

36 MATERIALS SCIENCE↗