National School on Neutron and X-ray Scattering
Explore the source record for details and available documents.
Engineering topics
Publications and source records attributed to Ekkebus, Allen E.
Explore the source record for details and available documents.
Peer review panels composed of 80 external scientists recently visited Oak Ridge National Laboratory (ORNL) to review almost 700 proposals for experiments on 23 instruments at the Spallation Neutron Source (SNS) and High Flux Isotope Reactor (HFIR). These were proposed for the time period from January-June 2012. About 40% of the proposals were approved for beam time and 20% were placed on an alternate list if time becomes available. The Hybrid Spectrometer HYSPEC at SNS began its commissioning in September 2011. HYSPEC is otpimized for studying low energy dynamics in single-crystal samples using a broad variety of sample environments, and is equipped with a polarization analysis capability. It is expected to be available for users on a limited basis in the second half of 2012. The detector tank of CORELLI has been installed on beamline 9 at SNS. Now that the tank is in place, banks of neutron detectors and boron carbide shielding will be installed around the interior. CORELLI is optimized to probe complex disorder in crystalline materials through diffuse scattering from single-crystal samples. It will begin commissioning in 2014. CORELLI is one of four instruments being developed under the SING II (SNS Instruments Next Generation II) project. The others are the Macromolecular Neutron Diffractometer (MANDI), the Vibrational Spectrometer (VISION, scheduled to begin commissioning in 2012), and the Time of Flight Ultra Small Angle Neutron Scattering Instrument (TOF-USANS). The single crystal neutron diffractometer IMAGINE, was deliverd to HFIR in October 2011. Preliminary testing has been carried out. IMAGINE will provide atomic resolution information on chemical, organic, metallo-organic and protein single crystals that will enable their chemical, physical and biological structure and function to be understood. This instrument will benefit scientists with interests in pharmaceuticals, minerals and other inorganic crystals, small molecules, molecular organo-metallic crystals and metal-organic frameworks (MOFs) molecular crystal structures. The quasi-Laue geometry, combined with a large solid angle detector, will enable rapid data collection from crystals with volume < 1mm{sup 1} and unit cell < 100 {angstrom}. Construction and installation of the optical system is in progress. Commissioning is expected to start in April 2012.
The 13th annual U.S. National School on Neutron and X-ray Scattering was held June 11 to 25, 2011, at both Oak Ridge and Argonne National Laboratories. This school brought together 65 early career graduate students from 56 different universities in the US and provided them with a broad introduction to the techniques available at the major large-scale neutron and synchrotron x-ray facilities. This school is focused primarily on techniques relevant to the physical sciences, but also touches on cross-disciplinary bio-related scattering measurements. During the school, students received lectures by over 30 researchers from academia, industry, and national laboratories and participated in a number of short demonstration experiments at Argonne's Advanced Photon Source (APS) and Oak Ridge's Spallation neutron Source (SNS) and High Flux Isotope Reactor (HFIR) facilities to get hands-on experience in using neutron and synchrotron sources. The first week of this year's school was held at Oak Ridge National Lab, where Lab director Thom Mason welcomed the students and provided a shitorical perspective of the neutron and x-ray facilities both at Oak Ridge and Argonne. The first few days of the school were dedicated to lectures laying out the basics of scattering theory and the differences and complementarity between the neutron and x-ray probes given by Sunil Sinha. Jack Carpenter provided an introduction into how neutrons are generated and detected. After this basic introduction, the students received lectures each morning on specific techniques and conducted demonstration experiments each afternoon on one of 15 different instruments at either the SNS or HFIR. Some of the topics covered during this week of the school included inelastic neutron scattering by Bruce Gaulin, x-ray and neutron reflectivity by Chuck Majkrazak, small-angle scattering by Volker Urban, powder diffraction by Ashfia Huq and diffuse scattering by Gene Ice.
No abstract prepared.
The neutron scattering facilities at Oak Ridge National Laboratory continue their development as new instruments are commissioned and join the user program at the Spallation Neutron Source and High Flux Isotope Reactor. More than 640 proposals were received for beam time during the January-May 2011 period on SNS and HFIR instruments with about half either being accepted or identified as alternates. The proposal call for the period June-December 2011, announced at http://neutrons.ornl.gov, will close February 23, 2011.
No abstract prepared.
No abstract prepared.
On Sunday, April 3, 2011, the Spallation Neutron Source (SNS) target reached an end-of-life condition, so user operations were shut down to change the stainless steel target housing the liquid mercury. This is the third change out of the target vessel; it is an expected event and took about two weeks. We took advantage of this time to do maintenance work that was planned for the longer summer shutdown. This will shorten that shutdown and recover the neutron production time. SNS restarted user operations on April 20.
The neutron spin echo (NSE) spectrometer was inaugurated by the Forschungszentrum Juelich at the Spallation Neutron Source (SNS) at Oak Ridge National Laboratory (ORNL) on November 2-5, 2009. The focus of the NSE spectrometer is soft-matter research, and its capabilities make it useful for other fields of modern condensed matter and materials science. The instrument is especially suited for analyzing slow dynamical processes and will enable increased understanding of molecular motion at nano- and mesoscopic levels. It will be a world-class spectrometer in both resolution and dynamic range, with a goal of six orders of magnitude (from 1 ps to 1 {mu}s) is anticipated using wavelengths between 0.25 < {lambda}/nm < 2.0 and a unique correctable field integral of 1 Tm.
No abstract prepared.