Search NASA⌕ Search

Engineering topics

Elliott, D S

Publications and source records attributed to Elliott, D S.

Measurements of the static polarizability of the 8s {sup 2}S{sub 1/2} state of atomic cesium

We present improved measurements of the static polarizability of the 8s {sup 2}S{sub 1/2} state of atomic cesium. Measured separately on two hyperfine components of the 6s {sup 2}S{sub 1/2}{yields}8s {sup 2}S{sub 1/2} transition, we determine an average polarizability of {alpha}{sub 8s}=9.490{+-}0.012 MHz (kV/cm){sup -2}, and a difference of only {Delta}{alpha}{sub 8s}=0.014{+-}0.016 MHz (kV/cm){sup -2}. {alpha}{sub 8s} is consistent with, but of higher precision (<0.15%) than, the previous measurement and theory. The difference {Delta}{alpha}{sub 8s} is smaller than our previous determination, and within 1 {sigma} of zero. Our new technique is insensitive to the frequency calibration of the laser.

74 ATOMIC AND MOLECULAR PHYSICS↗

Strong variation of the phase lag in the vicinity of autoionizing resonances

We have observed the phase lag in the sinusoidal variation of the asymmetric photoelectron angular distributions into two ionization channels of atomic barium using an {omega}-2{omega} excitation scheme. We excite atomic barium from the 6s6p {sup 1}P{sub 1} intermediate state electron to an energy between the 5d{sub 3/2}{epsilon} and the 5d{sub 5/2}{epsilon} thresholds with concurrent one-photon and two-photon interactions. The left-right asymmetry of the photoelectron angular distributions for the two energy-resolved product states, 6s{sub 1/2}{epsilon} and 5d{sub 3/2}{epsilon}, show sinusoidal modulation as a function of the relative phase of the {omega}-2{omega} fields. The phase difference between these signals, or phase lag, varies rapidly with the laser frequency when the interaction is nearly resonant with autoionizing resonances in the continuum. An exceptionally large phase lag variation of over 2{pi} was measured.

74 ATOMIC AND MOLECULAR PHYSICS↗

Weak signal detection using coherent control

We describe a technique based upon the principles of two-pathway coherent control that allows one to amplify the magnitude of a weak atomic or molecular transition. In our initial demonstrations, we amplify a weak Stark-induced transition (the 6s {sup 2}S{sub 1/2}{yields}8s {sup 2}S{sub 1/2} transition in atomic cesium) by coherently beating it with a stronger two-photon transition. We describe the measurements in detail, provide a quantitative discussion of the effects of beam overlap and alignment on the depth of modulation, and discuss the enhancement in the signal-to-noise ratio for this measurement technique over that of direct detection of the weak transition rate.

74 ATOMIC AND MOLECULAR PHYSICS↗